Building heating systems
Contents |
[edit] Introduction
Heating in buildings may be necessary to:
- Create comfortable conditions for occupants.
- To prevent condensation.
- For activities such as drying and cooking.
- For industrial processes.
In commercial buildings, heating for comfort might be provided alongside other building services in heating, ventilation and air conditioning (HVAC) systems.
[edit] Heat sources
Examples of fuels and heat sources include:
- Solid fuel – timber, coal, peat, biomass.
- Liquid – oil, liquid petroleum gas (LPG).
- Gas - natural gas, biogas.
- Electricity - grid, wind turbines, hydroelectricity, photovoltaics.
- Water – solar thermal, geothermal, ground source, water source.
- Air source.
- Heat recovery.
- Passive – solar gain, thermal mass.
- Internal heat loads - heat generated by people and equipment.
[edit] Heat generators
Heat sources and fuels can be used to generate heat by:
- Boilers.
- Solid fuel burners.
- Combined heat and power (CHP) plant.
- Electrical heaters.
- Gas heaters.
- Heat pumps.
[edit] Heat distribution
Heat generators can be local to the demand for heat, or can be centralised and distributed, either within a single building or on a wider basis as part of a district heating network. Heat distribution can be by:
- Air blown through ducts, plenums or occupied spaces.
- Water pumped through pipework.
- Steam distributed through pipework.
- Passive air movement.
- Passive diffusion of heat through thermal mass.
For more information, see Types of heating system.
[edit] Heat delivery
Distributed heat can be delivered within a space by:
- Fan coil units.
- Air handling units.
- Radiating panels.
- Embedded pipes in thermal mass.
[edit] Heat transfer
Heat transfer mechanisms include:
[edit] Controls
The amount of heat delivered to a space can be controlled:
- Locally by manual or automated thermostats, switches or dampers.
- Centrally by manual or automated thermostats, switches or dampers.
- Building management systems.
Heating control systems often require re-evaluation once buildings are completed and occupied. Systems may require fine-tuning as internal heat loads and occupant behaviour do not always conform with design expectations. Occupant training can be helpful to optimise the performance of heating systems, and occupants can be appreciative of a degree of local control.
[edit] Optimum temperatures
The human thermal environment is not straight forward and cannot be expressed in degrees. Nor can it be satisfactorily defined by acceptable temperature ranges. It is a personal experience dependent on a great number of criteria and can be different from one person to another within the same space.
- Air temperature.
- Air velocity.
- Radiant temperature.
- Relative humidity.
Personal factors:
For more information, see Thermal comfort.
[edit] Regulations
There is no legal requirement to achieve a minimum or maximum temperature within a building. The building regulations Part J, Part L and Part F set out requirements for safety, the provision of information, the consumption of energy, standards of construction, carbon emissions and ventilation requirements, but they do not prescribe temperatures.
The Health and Safety Executive suggest that an environment can be said to achieve ‘reasonable comfort’ when at least 80% of its occupants are thermally comfortable. This means that thermal comfort can be assessed by surveying occupants to find out whether they are dissatisfied with their thermal environment.
The Workplace (Health, Safety and Welfare) Regulations simply state that, ‘during working hours, the temperature in all workplaces inside buildings shall be reasonable’, however, the associated approved code of practice Workplace health, safety and welfare. Workplace (Health, Safety and Welfare) Regulations 1992. Approved Code of Practice suggests:
'The temperature in workrooms should normally be at least 16 degrees Celsius unless much of the work involves severe physical effort in which case the temperature should be at least 13 degrees Celsius. These temperatures may not, however, ensure reasonable comfort, depending on other factors such as air movement and relative humidity.’
There are no legal restrictions to maximum temperatures, however there is strict regulation of heat stress. Previous guidance by the HSE suggested that thermal comfort might be achieved between 13 and 30°C depending on the activity of occupants.
Operators of shared heating systems are subject to the Heat Network (Metering & Billing) Regulations 2014. The Regulations apply to systems in which water is heated or chilled at a central source of production before being piped to multiple buildings (district networks) or multiple customers in a single building (communal networks).
Heat suppliers are required to register their heat networks with the Office for Product Safety & Standards and, in the case of unmetered networks, may be required to install meters measuring customers’ actual consumption of heat. Where such meters are installed, heat suppliers are required to use them to bill customers according to their actual consumption.
[edit] Related articles on Designing Buildings
- Air handling unit.
- Amber warnings raise building overheating concern.
- Boiler markets and the green recovery.
- Building services.
- Building services engineer.
- Building regulations.
- Co-heating test.
- Cold stress.
- Combustion plant.
- Cooling.
- Corrosion in heating and cooling systems.
- Domestic boiler market 2019.
- ECA backs Government plans for low-carbon heat.
- European decarbonisation and heating technologies beyond 2021.
- Fan coils.
- Fan coil unit.
- Heat meter.
- Heat metering.
- Heat pump.
- Heat recovery.
- Heat stress.
- Heat transfer.
- Heating controls.
- Heating large spaces.
- Hot water.
- HVAC.
- Industrial gas boilers market 2020.
- Low carbon heating and cooling.
- Mechanical, electrical and plumbing MEP.
- Overheating.
- Pipework.
- Radiant heating.
- Radiator.
- Scotland publishes plans to reach net zero targets with Heat in Buildings Strategy.
- Tempering heating.
- Thermal comfort.
- Thermostat.
- Types of domestic heating system.
- Types of heating.
- Ultrasonic pipe testing.
- Underfloor heating.
Featured articles and news
Building Safety Regulator reforms
New roles, new staff and a new fast track service pave the way for a single construction regulator.
Cooling centres and cool spaces
Managing extreme heat in cities by directing the public to places for heat stress relief and water sources.
Winter gardens: A brief history and warm variations
Extending the season with glass in different forms and terms.
Restoring Great Yarmouth's Winter Gardens
Transforming one of the least sustainable constructions imaginable.
Construction Skills Mission Board launch sector drive
Newly formed government and industry collaboration set strategy for recruiting an additional 100,000 construction workers a year.
New Architects Code comes into effect in September 2025
ARB Architects Code of Conduct and Practice available with ongoing consultation regarding guidance.
Welsh Skills Body (Medr) launches ambitious plan
The new skills body brings together funding and regulation of tertiary education and research for the devolved nation.
Paul Gandy FCIOB announced as next CIOB President
Former Tilbury Douglas CEO takes helm.
UK Infrastructure: A 10 Year Strategy. In brief with reactions
With the National Infrastructure and Service Transformation Authority (NISTA).
Ebenezer Howard: inventor of the garden city. Book review.
The Grenfell Tower fire, eight years on
A time to pause and reflect as Dubai tower block fire reported just before anniversary.
Airtightness Topic Guide BSRIA TG 27/2025
Explaining the basics of airtightness, what it is, why it's important, when it's required and how it's carried out.
Construction contract awards hit lowest point of 2025
Plummeting for second consecutive month, intensifying concerns for housing and infrastructure goals.
Understanding Mental Health in the Built Environment 2025
Examining the state of mental health in construction, shedding light on levels of stress, anxiety and depression.
The benefits of engaging with insulation manufacturers
When considering ground floor constructions.
Lighting Industry endorses Blueprint for Electrification
The Lighting Industry Association fully supports the ECA Blueprint as a timely, urgent call to action.