Natural ventilation of buildings

Open window.jpg

Ventilation is necessary in buildings to remove ‘stale’ air and replace it with ‘fresh’ air:

Contents

[edit] Brief history

The origins the word ventilation lie in the Latin word ventilatio, or ventulus meaning a breeze, from ventus meaning wind. Ventilatus, was the past participle of ventilare which was interpreted as to brandish, toss in the air, winnow, fan, agitate or set in motion. In early history the roman hypocaust system, was a heated underfloor ventilation system where heated air was distributed through a building via pipes and tile vents. In the early 1630's, King Charles I decreed ceilings in England to be 10 feet (3 meters) and windows taller than their width to allow for natural ventilation as it was assumed poor indoor conditions were causing the nations health problems. By 1660 ventilation was being described as the process of replacing foul air in an enclosed place with fresh, pure air. By the 1740's it was commonly referred to as the act of supplying a room with fresh air, and a blowing wheel system was actually installed in the Houses of Parliament in London. On the side, in slang, ventilation had an adopted meaning of the shoot someone ie by making holes in them, to ventilate them. In the 1840's the Parliament system had been upgraded to a heating and cooling ventilation system, by the early 1900's simple air conditioning systems that started appearing would soon become very commonplace. Whilst from 2000 onwards, with the increasingly awareness of energy conservation, alternative systems with advance natural ventilation, mixed mode and heat recovery continue to become more and more commonplace.

[edit] Natural ventilation approaches

Very broadly, ventilation in buildings can be classified as ‘natural’ or ‘mechanical’

Mixed mode (MM), hybrid or assisted ventilation systems, sometimes called intermittent mandatory ventilation (IMV), involve natural ventilation supplemented by mechanical systems to ensure minimal background ventilation, whilst advanced natural ventilation (ANV) is some times used to describe more complex systems that involve certain architecture features such as ventilation stacks, chimneys, shafts or cowls, atria spaces or light wells and wind catchers, cowls or scoops, which may or may not involve some automation.

Natural ventilation tends to cost less to build, operate and maintain than mechanical ventilation, and so this is generally the first option investigated during the design process. However, there may be circumstances where natural ventilation is not possible and so mechanical ventilation is necessary or where advanced natural ventilation systems increase relative costs of natural ventilation strategies as a result of the required inclusion of specific architectural design features.

Some of these issues can be avoided or mitigated by careful location, orientation, siting, zoning and design of the building.

Natural ventilation is generally categorised as:

The effectiveness of these mechanisms is dependent on a wide number of variables, but very broadly:

Combinations of these ventilation strategies, with the additional exploitation of thermal mass can produce a wide range of natural ventilation solutions, such as trombe walls, solar chimneys and so on.

Passive design.jpg

[edit] Advanced natural ventilation approaches

Designing natural ventilation can become extremely complex because of the interaction between cross ventilation and the stack effect as well as complex building geometries and the distribution of openings. This can require analysis using specialist software analysis systems such as computational fluid dynamics.

These more complex natural ventilation systems might be described as advanced natural ventilation (ANV), where strategies go beyond simply bringing fresh air into and extracting stale air out of buildings, via single sided or cross ventilated opening lights, windows or trickle ventilators. Advanced natural ventilation (ANV) describes strategies that might include specific architectural features to promote natural ventilation through stack effect, buoyancy or wind driven ventilation such as ventilation stacks, chimneys, shafts or cowls, atria spaces or light wells and wind catchers, cowls or scoops, sometimes involving automation.

It can sometimes be beneficial to automate natural ventilation systems, or to provide training for occupants and monitor behaviour to ensure systems continue to be operated as intended because natural ventilation is also influenced by occupant behaviour. As an example a person near to a window may choose to close it because of close proximity drafts, which might impact the level of carbon dioxide in the whole room by reducing the ventilation, which can in turn impact performance of others in the workplace.

However from the other perspective over automation of ventilation systems can leave occupants feeling disempowered, and unable to locally influence the conditions around them (for example by opening or closing a window themself) as a result this can have the consequence that they are more likely to express dissatisfaction with the overall internal conditions and environment they find themselves. In some cases even if the internal environment is in fact optimal when measure empirically.

In modern buildings, which tend to be designed to be completely sealed from the outside unless windows or other ventilators are open, problems, such as condensation, can occur during the winter when openings are closed. As a result, ‘trickle ventilation’, or 'background' ventilation tends to be provided to ensure there is always an adequate level of ventilation. Trickle ventilators can be self-balancing, with the size of the open area depending on the air pressure difference across it.

It is possible, although relatively complicated to include heat recovery in natural ventilation systems so that during cooler conditions, heat recovered from extract air is used to pre-heat fresh air entering the building. These systems are normally referred to as mechanical ventilation heat recovery or MVHR, and are a integral part of design strategies such as the Passivhaus standard, along with high levels of airtightness, insulation and high performing glazing. These elements combined can help to dramatically reduce the heat energy require in a space, they can also help reduce the surface temperature differential between for example glazed surfaces and solid surfaces which can help improve comfort leves near those surfaces such as for example a desk placed next to a window, during colder winter months.

In addition, thermal mass can be used to pre-heat supply air. For example, see Thermal Labyrinth and Ground preconditioning of supply air.

Schematic section.jpg

Ventilation in buildings is regulated by Part F of the building regulations. Approved document F includes standards for ventilation and air quality for all buildings and requirements for the prevention of condensation. The types of ventilation covered include; mechanical, passive stack, background and purge (rapid). In the 2021 revision, Approved Document F was been split into two volumes, with Volume 1 relating to dwellings, and Volume 2 for non-dwellings. The Domestic Ventilation Compliance Guide was also amalgamated into the document for ease of understanding and use.

Approved Document F Volume 1, 2021 edition, defines natural ventilation as: 'Ventilation provided by thermal, wind or diffusion effects through doors, windows or other intentional openings without the use of mechanically driven equipment. For the purposes of this approved document, a natural ventilation strategy may include decentralised extract ventilation from rooms where water vapour or pollutants are likely to be released to minimise their spread to the rest of the building.'

See Approved document F for more information.