Gross internal area GIA
[edit] What are the different ways of measuring the areas of buildings?
The area of a building can be measured in a number of different ways:
- Gross external area (GEA).
- Gross internal area (GIA) or gross internal floor area (GIFA).
- Net internal area (NIA).
- Total useful floor area (TUFA).
- Usable floor area.
It is very important when describing the area of a building to be clear about which measure is being used, for example in planning applications, building regulation applications, property sales, lease negotiations, rating valuations, and so on.
[edit] What is gross internal area?
The UK government’s Valuation Office Agency (VOA) Code of measuring practice: definitions for rating purposes suggests that gross internal area (GIA) includes:
- Areas occupied by internal walls (whether structural or not) and partitions.
- Service accommodation such as WCs, showers, and changing rooms.
- Columns, piers, whether free standing or projecting inwards from an external wall, chimney breasts, lift wells, stairwells, and so on.
- Lift rooms, plant rooms, tank rooms, fuel stores, whether or not above roof level.
- Open-sided covered areas (should be stated separately).
Gross internal area excludes:
- Open balconies.
- Open fire escapes.
- Open-sided covered ways.
- Open vehicle parking areas, terraces and so on.
- Minor canopies.
- Any area with a ceiling height of less than 1.5m (except under stairways).
- Any area under the control of service or other external authorities.
The VOA code is in general agreement with RICS Guidance Note, A guide for Property Professionals, 6th Edition Code of measuring practice 2007, other than, areas with a headroom of less than 1.5m which are excluded from the VOA measurement.
NRM1: Order of cost estimating and cost planning for capital building work, defines ‘gross internal floor area’ (GIFA) (or gross internal area (GIA)) as: ‘…the area of a building measured to the internal face of the perimeter walls at each floor level. The rules of measurement of gross internal floor area are defined in the latest edition of the RICS Code of Measuring Practice.’
According to ‘Elemental Standard Form of Cost Analysis, Principles, Instructions, Elements and Definitions, 4th (NRM) Edition’ written by RICS in 2012 and published by BCIS, GIFA includes:
- Areas occupied by internal walls and partitions.
- Columns, piers chimney breasts, stairwells, lift-wells, other internal projections, vertical ducts, and the like.
- Atria and entrance halls with clear height above, measured at base level only
- Internal open sided balconies, walkways, and the like.
- Structural, raked or stepped floors are treated as a level floor measured horizontally.
- Horizontal floors with permanent access below structural, raked or stepped floors.
- Corridors of a permanent essential nature (e.g. fire corridors, smoke lobbies, etc.).
- Mezzanine areas intended for use with permanent access.
- Lift rooms, plant rooms, fuel stores, tank rooms which are housed in a covered structure of a permanent nature, whether or not above main roof level.
- Service accommodation such as toilets, toilet lobbies, bathrooms, showers, changing rooms, cleaners’ rooms and the like.
- Projection rooms.
- Voids over stairwells and lift shafts on upper floors.
- Loading bays.
- Areas with headroom of less than 1.5 m.
- Pavement vaults.
- Garages.
- Conservatories.
It excludes:
- Perimeter wall thickness and external projections.
- External open-sided balconies, covered ways and fire escapes.
- Canopies.
- Voids over or under structural, raked or stepped floors.
- Greenhouses, garden stores, fuel stores and the like in residential property.
And that:
- The GIFA excludes the thickness of perimeter walls, but includes the thickness of all internal walls. Therefore, it is necessary to identify what constitutes a separate building, e.g. the sum of the GIFA of a terrace of buildings, treated as separate buildings, will be different from the terrace treated as a single building.
- Areas of open ground floors and the like should be excluded.
- ‘Internal face’ means the structural wall or plaster coat applied to the structural wall, not the surface of internal linings installed by the occupier.
- Lift rooms, etc. should be included if housed in a roofed structure having the appearance of permanence (e.g. made of brick or similar building material). Areas covered by enclosures designed solely to mask plant, rooflines, etc. should be excluded.
- The presence of steps or changes in floor levels should be noted.
- Attention is drawn to the exclusion of voids over atria at upper levels and the inclusion of voids over stairs, etc. Where an atrium-like space is formed to create an entrance feature, and this also accommodates a staircase, this does not become a stairwell but remains an atrium measurable at base level only.
- Walkways across an atrium at upper levels should be included in the measurement of upper floors.
- Areas in the roof space intended for use with permanent access should be included in the measurement of upper floors and measured to internal face of the enclosing wall or the roof at floor level.
- Re-entrant balconies, i.e. open sided balconies within the predominant line of the external wall should be treated as open sided balconies and excluded.
[edit] Related articles on Designing Buildings
Featured articles and news
Future Homes Standard Essentials launched
Future Homes Hub launches new campaign to help the homebuilding sector prepare for the implementation of new building standards.
Building Safety recap February, 2026
Our regular run-down of key building safety related events of the month.
Planning reform: draft NPPF and industry responses.
Last chance to comment on proposed changes to the NPPF.
A Regency palace of colour and sensation. Book review.
Delayed, derailed and devalued
How the UK’s planning crisis is undermining British manufacturing.
How much does it cost to build a house?
A brief run down of key considerations from a London based practice.
The need for a National construction careers campaign
Highlighted by CIOB to cut unemployment, reduce skills gap and deliver on housing and infrastructure ambitions.
AI-Driven automation; reducing time, enhancing compliance
Sustainability; not just compliance but rethinking design, material selection, and the supply chains to support them.
Climate Resilience and Adaptation In the Built Environment
New CIOB Technical Information Sheet by Colin Booth, Professor of Smart and Sustainable Infrastructure.
Turning Enquiries into Profitable Construction Projects
Founder of Develop Coaching and author of Building Your Future; Greg Wilkes shares his insights.
IHBC Signpost: Poetry from concrete
Scotland’s fascinating historic concrete and brutalist architecture with the Engine Shed.
Demonstrating that apprenticeships work for business, people and Scotland’s economy.
Scottish parents prioritise construction and apprenticeships
CIOB data released for Scottish Apprenticeship Week shows construction as top potential career path.
From a Green to a White Paper and the proposal of a General Safety Requirement for construction products.
Creativity, conservation and craft at Barley Studio. Book review.
The challenge as PFI agreements come to an end
How construction deals with inherited assets built under long-term contracts.
Skills plan for engineering and building services
Comprehensive industry report highlights persistent skills challenges across the sector.
Choosing the right design team for a D&B Contract
An architect explains the nature and needs of working within this common procurement route.
Statement from the Interim Chief Construction Advisor
Thouria Istephan; Architect and inquiry panel member outlines ongoing work, priorities and next steps.


























Comments
A question - what about undercroft spaces? Meaning an open area of building that has the same building above it and columns coming down to ground, with entrance to the building at ground.