Gross internal area GIA
[edit] What are the different ways of measuring the areas of buildings?
The area of a building can be measured in a number of different ways:
- Gross external area (GEA).
- Gross internal area (GIA) or gross internal floor area (GIFA).
- Net internal area (NIA).
- Total useful floor area (TUFA).
- Usable floor area.
It is very important when describing the area of a building to be clear about which measure is being used, for example in planning applications, building regulation applications, property sales, lease negotiations, rating valuations, and so on.
[edit] What is gross internal area?
The UK government’s Valuation Office Agency (VOA) Code of measuring practice: definitions for rating purposes suggests that gross internal area (GIA) includes:
- Areas occupied by internal walls (whether structural or not) and partitions.
- Service accommodation such as WCs, showers, and changing rooms.
- Columns, piers, whether free standing or projecting inwards from an external wall, chimney breasts, lift wells, stairwells, and so on.
- Lift rooms, plant rooms, tank rooms, fuel stores, whether or not above roof level.
- Open-sided covered areas (should be stated separately).
Gross internal area excludes:
- Open balconies.
- Open fire escapes.
- Open-sided covered ways.
- Open vehicle parking areas, terraces and so on.
- Minor canopies.
- Any area with a ceiling height of less than 1.5m (except under stairways).
- Any area under the control of service or other external authorities.
The VOA code is in general agreement with RICS Guidance Note, A guide for Property Professionals, 6th Edition Code of measuring practice 2007, other than, areas with a headroom of less than 1.5m which are excluded from the VOA measurement.
NRM1: Order of cost estimating and cost planning for capital building work, defines ‘gross internal floor area’ (GIFA) (or gross internal area (GIA)) as: ‘…the area of a building measured to the internal face of the perimeter walls at each floor level. The rules of measurement of gross internal floor area are defined in the latest edition of the RICS Code of Measuring Practice.’
According to ‘Elemental Standard Form of Cost Analysis, Principles, Instructions, Elements and Definitions, 4th (NRM) Edition’ written by RICS in 2012 and published by BCIS, GIFA includes:
- Areas occupied by internal walls and partitions.
- Columns, piers chimney breasts, stairwells, lift-wells, other internal projections, vertical ducts, and the like.
- Atria and entrance halls with clear height above, measured at base level only
- Internal open sided balconies, walkways, and the like.
- Structural, raked or stepped floors are treated as a level floor measured horizontally.
- Horizontal floors with permanent access below structural, raked or stepped floors.
- Corridors of a permanent essential nature (e.g. fire corridors, smoke lobbies, etc.).
- Mezzanine areas intended for use with permanent access.
- Lift rooms, plant rooms, fuel stores, tank rooms which are housed in a covered structure of a permanent nature, whether or not above main roof level.
- Service accommodation such as toilets, toilet lobbies, bathrooms, showers, changing rooms, cleaners’ rooms and the like.
- Projection rooms.
- Voids over stairwells and lift shafts on upper floors.
- Loading bays.
- Areas with headroom of less than 1.5 m.
- Pavement vaults.
- Garages.
- Conservatories.
It excludes:
- Perimeter wall thickness and external projections.
- External open-sided balconies, covered ways and fire escapes.
- Canopies.
- Voids over or under structural, raked or stepped floors.
- Greenhouses, garden stores, fuel stores and the like in residential property.
And that:
- The GIFA excludes the thickness of perimeter walls, but includes the thickness of all internal walls. Therefore, it is necessary to identify what constitutes a separate building, e.g. the sum of the GIFA of a terrace of buildings, treated as separate buildings, will be different from the terrace treated as a single building.
- Areas of open ground floors and the like should be excluded.
- ‘Internal face’ means the structural wall or plaster coat applied to the structural wall, not the surface of internal linings installed by the occupier.
- Lift rooms, etc. should be included if housed in a roofed structure having the appearance of permanence (e.g. made of brick or similar building material). Areas covered by enclosures designed solely to mask plant, rooflines, etc. should be excluded.
- The presence of steps or changes in floor levels should be noted.
- Attention is drawn to the exclusion of voids over atria at upper levels and the inclusion of voids over stairs, etc. Where an atrium-like space is formed to create an entrance feature, and this also accommodates a staircase, this does not become a stairwell but remains an atrium measurable at base level only.
- Walkways across an atrium at upper levels should be included in the measurement of upper floors.
- Areas in the roof space intended for use with permanent access should be included in the measurement of upper floors and measured to internal face of the enclosing wall or the roof at floor level.
- Re-entrant balconies, i.e. open sided balconies within the predominant line of the external wall should be treated as open sided balconies and excluded.
[edit] Related articles on Designing Buildings
Featured articles and news
Repairing historic stone and slate roofs
The need for a code of practice and technical advice note.
UKCW London to tackle sector’s most pressing issues
AI and skills development, ecology and the environment, policy and planning and more.
Managing building safety risks
Across an existing residential portfolio; a client's perspective.
ECA support for Gate Safe’s Safe School Gates Campaign.
Core construction skills explained
Preparing for a career in construction.
Retrofitting for resilience with the Leicester Resilience Hub
Community-serving facilities, enhanced as support and essential services for climate-related disruptions.
Some of the articles relating to water, here to browse. Any missing?
Recognisable Gothic characters, designed to dramatically spout water away from buildings.
A case study and a warning to would-be developers
Creating four dwellings... after half a century of doing this job, why, oh why, is it so difficult?
Reform of the fire engineering profession
Fire Engineers Advisory Panel: Authoritative Statement, reactions and next steps.
Restoration and renewal of the Palace of Westminster
A complex project of cultural significance from full decant to EMI, opportunities and a potential a way forward.
Apprenticeships and the responsibility we share
Perspectives from the CIOB President as National Apprentice Week comes to a close.
The first line of defence against rain, wind and snow.
Building Safety recap January, 2026
What we missed at the end of last year, and at the start of this.





















Comments
A question - what about undercroft spaces? Meaning an open area of building that has the same building above it and columns coming down to ground, with entrance to the building at ground.