Flashing is a sheet of thin, impervious material used to prevent water penetration or seepage into a building and to direct the flow of moisture in walls. Flashing is particularly important at junctions such as roof hips and valleys, joints between roofs and vertical walls, roof intersections or projections such as chimneys, dormers, vent pipes, window openings, and so on.
There are two categories of flashing, exposed and embedded. Exposed flashings are partially exposed to the outside and usually made of a sheet metal, while embedded (or concealed) flashing can be metal or non-metal and are typically used at the base of cavity walls, above openings, at sills and shelf angles (a structural steel member that supports and transfers the brick’s dead load back to the building frame), and under copings.
[edit] Types of flashing
There are different terms given to flashing, often determined by where they are used or their shape.
- Roof flashing: Installed around projections or intersections to direct water from seams or joints.
- Wall flashing: Typically embedded in wall interruptions such as windows, either to prevent water ingress or direct water that has entered back outside.
- Sill flashing: Concealed under windows or door thresholds to prevent water ingress.
- Channel flashing: U-shaped channel used where the edge of a tile roof meets a wall.
- Through wall flashing: Directs water to weep holes by spanning the thickness of the wall.
- Cap flashing: Above windows and doors.
- Drip edge: A metal projection often found at roof edges.
- Stepped flashing: Flashing materials that overlap each other in steps where a junction is on a slope, such as around chimney stacks on pitched roofs.
- Kickout flashing: The lowermost step flashing at the bottom of roof/wall intersection, used to deflect water away from the wall.
- Pipe flashing: Used where roofs are penetrated by pipes.
- Valley flashing: Where two intersecting roof planes form a valley in which water may pool.
[edit] Construction of flashing
Flashing has to be engineered and installed with care so that water is deflected away from the building. Improper installation can result in water being directed into a building.
Expansion joints should be provided for long runs of metal flashing to allow movement without causing deformation.
Continuous flashing is one solid piece of material, and is sometimes seen where a sloping roof and a vertical sidewall meet to form a horizontal line.
Step flashing allows a roof to abut brickwork, instance when a lower height roof meets a wall, a roof meets a chimney, or a conservatory roof meets a house wall. Step flashing offers far better protection from leaks than continuous flashing, because even if a single piece of step flashing fails, the water hits the next lower piece, which directs the water onto the shingle and drains down the roof.
[edit] Materials
There are many materials that can be used for flashing; the important thing is that they do not degrade from coming into contact with incompatible materials and that they are impermeable to water. The most common flashing materials are metal, plastic, or rubber.
[edit] Metal flashing materials
Lead is traditionally used as a flashing material around upstands in roofs, such as chimneys because of its durability. The minimum specification that should be used is Code 4 lead (1.8 mm) which is both malleable and resistant to fatigue splits that could be caused by expansion and contraction. Code 3 (1.32 mm) is thinner, lighter and cheaper, and is commonly used for lead soakers which are the concealed waterproof sections positioned underneath slates and plain tiles.
Other materials that can be used as metal flashings include aluminium which is also durable and relatively inexpensive. However, aluminium will corrode if left in contact with pressure-treated wood, and also wet mortar and plaster.
Copper is malleable, strong and has a high resistance to the corrosive effects of mortars and wood-preservatives. Cold rolled copper is recommended rather than soft copper as it offers more resistance to expansion and contraction stresses, although soft copper is useful where there are complex roof shapes.
Soft zinc is a very malleable material which makes it suitable for complex roof shapes.
There are also arrangements of metals that can be coated for use as flashings, such as:
- Galvanized steel, which is inexpensive but lacks the durability of other metals.
- Lead-coated copper.
- Anodized aluminium.
- Terne-coated copper.
- Galvalume (aluminium-zinc alloy coated sheet steel).
- Polyvinylidene fluoride.
Neither copper nor lead can be used in contact with or above aluminium, zinc or coated steel without an increased risk of premature corrosion. Coastal areas face the risk of accelerated corrosion due to salt spray and so stainless steel, copper or coated aluminium are often recommended.
[edit] Non-metal flashing materials
Also known as flexible flashing materials, these include rubberised asphalt, butyl rubber, PVC and acrylic. They have different chemical compatibilities, resistance to ultraviolet light exposure, application temperature ranges and so on. Adhesive-backed materials are easily installed but consideration should be given to their long-term water resistance and most should not be left permanently exposed to the weather unless laminated with a top surface of aluminium foil.
[edit] Related articles on Designing Buildings
- Aluminium.
- Cavity tray.
- Cloaking.
- Damp.
- Damp proof course.
- Firring.
- Flat roof defects.
- Lead.
- Lead in construction.
- Penetrating damp.
- Rising damp.
- Roofing defects.
- Vapour barrier.
- Wall ties.
- Weep hole.
[edit] External references
- Old House Web - Flashing: What is it and why is it important?
- ‘Building Construction Handbook’ (6th ed.), CHUDLEY, R., GREENO, R., Butterworth-Heinemann, (2007)
- Tools Recap - Aluminum vs. Copper Flashing
Featured articles and news
Do you take the lead in a circular construction economy?
Help us develop and expand this wiki as a resource for academia and industry alike.
Warm Homes Plan Workforce Taskforce
Risks of undermining UK’s energy transition due to lack of electrotechnical industry representation, says ECA.
Cost Optimal Domestic Electrification CODE
Modelling retrofits only on costs that directly impact the consumer: upfront cost of equipment, energy costs and maintenance costs.
The Warm Homes Plan details released
What's new and what is not, with industry reactions.
Could AI and VR cause an increase the value of heritage?
The Orange book: 2026 Amendment 4 to BS 7671:2018
ECA welcomes IET and BSI content sign off.
How neural technologies could transform the design future
Enhancing legacy parametric engines, offering novel ways to explore solutions and generate geometry.
Key AI related terms to be aware of
With explanations from the UK government and other bodies.
From QS to further education teacher
Applying real world skills with the next generation.
A guide on how children can use LEGO to mirror real engineering processes.
Data infrastructure for next-generation materials science
Research Data Express to automate data processing and create AI-ready datasets for materials research.
Wired for the Future with ECA; powering skills and progress
ECA South Wales Business Day 2025, a day to remember.
AI for the conservation professional
A level of sophistication previously reserved for science fiction.
Biomass harvested in cycles of less than ten years.
An interview with the new CIAT President
Usman Yaqub BSc (Hons) PCIAT MFPWS.
Cost benefit model report of building safety regime in Wales
Proposed policy option costs for design and construction stage of the new building safety regime in Wales.
Do you receive our free biweekly newsletter?
If not you can sign up to receive it in your mailbox here.

























Comments
Hi.
Is it possible to add information on the pointing material for flashing. I was asked today if the zinc flashing should be pointed with mortar or mastic