Choosing the correct glazed facade heating system
There are numerous factors to consider when it comes to choosing an appropriate heating solution for glass façade buildings.
Andy Williams, Technical Consultant at Jaga, discusses the increasing demand for heating solutions which combat the practical issues regarding glazed façades, and how the correct solution can be determined.
Contents |
[edit] Introduction
Contemporary building design shows that we have an increasing appreciation for natural light. That appreciation has manifested itself in the form of floor-to-ceiling glass windows, which have become an architectural feature in many new builds to create a sense of openness and space.
Take the capital for example, skyscrapers such as 20 Fenchurch Street, the Leadenhall Building, the Gherkin and the Shard have all been designed and built using glazed façades.
Glass is often chosen as it is a superb way of utilising natural light, reducing energy consumption, harnessing the solar comfort of the sun and insulating or interiors from noise pollution. Clean glass lines are also aesthetically pleasing, a crucial consideration for Architectural Technologists.
However, glass is notoriously poor at heat retention, and consequently buildings that are made up of glazed façades can experience high levels of heat loss — making warming the building a challenge. Additionally, glazed façades are extremely vulnerable to condensation build up.
The principle cause of condensation on the inside of glazed façades is high internal humidity levels, coupled with low outside temperatures — common in tall, multi-level, commercial builds. In order to maintain the aesthetic desired and prevent condensation and heat loss, the heating and ventilation in the areas where glazed façades are used needs to be thoroughly considered.
[edit] Be clear on the purpose of façade heating and cooling
When selecting a façade heating system, an important design aspect that must be considered is the purpose of the façade heater. The heating solution can be designed to provide effective space heating, mitigate heat loss, eliminate condensation, cooling and ventilation - or even be used for a combination of all of them. The intention of use will affect the preferred solution and will need to be considered early on in the design stage.
[edit]
It is generally considered that trench heating is an ideal façade heating system due to its versatility. Whether it is the range of depths, widths and lengths, the option of grilles, there are numerous trench solutions available. A further advantage of trench heating is that it is a ‘hidden’ solution — it doesn’t take up wall space and can therefore be easily installed in front of floor-to-ceiling glazing, without impacting the aesthetic design.
Interestingly, it is also now possible for trench heating to not only heat, but to have the additional function of ventilating — and sometimes even cooling. Often in office and commercial environments, Indoor Air Quality (IAQ) is of particular interest, as correct ventilation can positively impact occupant health, comfort and productivity. Trench radiators can now be used to introduce fresh air by a direct connection to the outside, rather than using a separate ventilation system.
It is also important to consider that when cooling is to be included in the façade solution, additional power may be required to push the cool air up and throughout the room. This can be provided using a Dynamic Boost Effect (DBE) fan unit, which can be attached to the radiator in order to maintain rapid and accurate room comfort conditions, or a quick boost of heat if required.
However, as versatile as a trench radiator can be there are still times where trench heating is not viable for certain applications. These include when floor voids are either too shallow for trench heating or are completely solid, or where construction costs for creating trench channels are prohibitive.
[edit] Perimeter heating: the discrete alternative
In these instances, low-level, free-standing perimeter heating can be an effective alternative. Floor-mounted heating provides all of the benefits of trench heating — circulating and heating cool air from windows, minimal dimensions — but can be useful when technical issues will not allow trench heating to be installed.
Free-standing radiators can also be easily installed at the very end of a project, and can even meet Low Surface Temperature (LST) requirements. However, whilst perimeter heating is less visually obtrusive than other forms of heating, this system still takes up valuable floor space. For lettable spaces this is incredibly important, as the more space required for heating and ventilation, the less available space to let.
Certain types of trench and perimeter heating also contain an ultra-fast Low-H2O casing element which is either hidden under the grille or within the radiator. This element means that only a tenth of the water is required to heat the system when compared to standard, steel-panel radiators, which means that energy bills for the building can be reduced by up to 16%. Even though substantial energy savings can be made, the system will still remain incredibly responsive to temperature change.
[edit] As clear as glass
One thing is crystal clear. The number of buildings comprised of glazed façades are only going to increase over time. So, it is crucial that when design decisions are made on how the spaces that they enclose should be heated, aforementioned factors such as heat output, available space and aesthetics should all be taken into consideration.
This article was originally published in AT Journal Spring Edition 2017.
--CIAT
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Welsh Skills Body (Medr) launches ambitious plan
The new skills body brings together funding and regulation of tertiary education and research for the devolved nation.
Paul Gandy FCIOB announced as next CIOB President
Former Tilbury Douglas CEO takes helm.
UK Infrastructure: A 10 Year Strategy. In brief with reactions
With the National Infrastructure and Service Transformation Authority (NISTA).
Ebenezer Howard: inventor of the garden city. Book review.
The Grenfell Tower fire, eight years on
A time to pause and reflect as Dubai tower block fire reported just before anniversary.
Airtightness Topic Guide BSRIA TG 27/2025
Explaining the basics of airtightness, what it is, why it's important, when it's required and how it's carried out.
Construction contract awards hit lowest point of 2025
Plummeting for second consecutive month, intensifying concerns for housing and infrastructure goals.
Understanding Mental Health in the Built Environment 2025
Examining the state of mental health in construction, shedding light on levels of stress, anxiety and depression.
The benefits of engaging with insulation manufacturers
When considering ground floor constructions.
Lighting Industry endorses Blueprint for Electrification
The Lighting Industry Association fully supports the ECA Blueprint as a timely, urgent call to action.
BSRIA Sentinel Clerk of Works Training Case Study
Strengthening expertise to enhance service delivery with integrated cutting-edge industry knowledge.
Impact report from the Supply Chain Sustainability School
Free sustainability skills, training and support delivered to thousands of UK companies to help cut carbon.
The Building Safety Forum at the Installershow 2025
With speakers confirmed for 24 June as part of Building Safety Week.
The UK’s largest air pollution campaign.
Future Homes Standard, now includes solar, but what else?
Will the new standard, due to in the Autumn, go far enough in terms of performance ?
BSRIA Briefing: Cleaner Air, Better tomorrow
A look back at issues relating to inside and outside air quality, discussed during the BSRIA briefing in 2023.
Restoring Abbotsford's hothouse
Bringing the writer Walter Scott's garden to life.
Reflections on the spending review with CIAT.