The term 'glazing' refers to the glass components of a building's façade or internal surfaces. Historically, windows were generally single glazed, consisting of just a single layer of glass, today there are many different options for glazing. A substantial amount of heat is lost through the window, and so double and triple glazed units have been developed to provide more insulation, improving the energy efficiency of a building.
The building regulations in England and Wales require that new and replacement window units must meet certain energy efficiency requirements. Approved Document L of the building regulations classifies an external window as a 'controlled fitting', which refers to the whole unit including the frame. New and replacement windows in existing homes in England, Wales and Scotland must have a Window Energy Rating (WER) of at least band C or have a U-value of no more than 1.6 W/m²K. This is intended to reduce heat transfer, and so the requirement for heating or cooling, resulting in lower energy consumption and lower carbon emissions.
Single glazing comprises one layer of glass, bedded into the window frame. Single glazing is sometimes fixed with linseed oil putty and secured with glazing nails into the frame. Glazing beads can further secure the glass and may be screwed and glued to the frame. If the window frame is timber it must be painted or otherwise treated to avoid water ingress. Typically, single glazing can achieve a U-value of around 4.5 W/m²K. The sound reduction achieved by single glazing (6 mm thick) is typically around 27 dB
Double glazing comprises two layers of glass separated by a spacer bar and a continuous hollow frame typically made from aluminium or UPVC or some other low heat-conductive material such as timber. The spacer bar is bonded to the panes using a primary and secondary seal which creates an airtight cavity, typically with 6-20 mm between the two layers of glass. Larger cavities may be provided to achieve greater sound reduction. The space is filled with air or with a gas such as argon, which improves the thermal properties of the window. Good double glazing can achieve a U-value of around 1.2 W/m²K. The sound reduction achieved by double glazing (100 mm air space) is around 42 dB
For more information see: Single glazing and Double glazing.
Double glazing provides benefits, such as improved thermal comfort and better acoustic performance and increased security as well as reduced solar gain in the summer and a reduction in the occurrence of condensation. However, it is more expensive, heavier and may be more difficult to instal.
Single glazing might be beneficial in climates or building types that do not require heat retention, such as storage facilities.
A more economical option to replacing single glazed windows can be to instal secondary glazing. Secondary glazing involves the installation of an additional pane or panes of glass and a internal frame to existing windows. This can be used be used to improve sound insulation and to reduce heat loss and draughts through windows, or in situations where it is not permitted to change existing glazing such as listed buildings.
Secondary glazing may be suitable for:
- Listed buildings, period properties and heritage/conservation areas.
- Areas where there is traffic noise (such as hotels on main roads).
- Properties where it may be uneconomical to instal double glazing.
- Properties where it would be difficult to modify existing external windows (such as single glazed timber sash windows).
- Windows that require noise reduction, draught reduction.
[edit] Related Articles on Designing Buildings Wiki
Featured articles and news
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.
Plumbing and heating for sustainability in new properties
Technical Engineer runs through changes in regulations, innovations in materials, and product systems.
Awareness of the Carbon Border Adjustment Mechanism
What CBAM is and what to do about it.
The new towns and strategic environmental assessments
12 locations of the New Towns Taskforce reduced to 7 within the new towns draft programme and open consultation.
Buildings that changed the future of architecture. Book review.
The Sustainability Pathfinder© Handbook
Built environment agency launches free Pathfinder© tool to help businesses progress sustainability strategies.
Government outcome to the late payment consultation, ECA reacts.
IHBC 2025 Gus Astley Student Award winners
Work on the role of hewing in UK historic conservation a win for Jack Parker of Oxford Brookes University.
Future Homes Building Standards and plug-in solar
Parts F and L amendments, the availability of solar panels and industry responses.
How later living housing can help solve the housing crisis
Unlocking homes, unlocking lives.
Preparing safety case reports for HRBs under the BSA
A new practical guide to preparing structural inputs for safety cases and safety case reports published by IStructE.
Male construction workers and prostate cancer
CIOB and Prostate Cancer UK encourage awareness of prostate cancer risks, and what to do about it.