U-values
Contents |
[edit] What are U-values?
U-values (sometimes referred to as heat transfer coefficients or thermal transmittances) are a measure of how effective the elements of a building's fabric are as insulators. That is, the degree to which they prevent heat from transmitting between the inside and the outside of a building.
The lower the U-value of an element of a building's fabric, the more slowly heat is able to transmit through it, and so the better it performs as an insulator.
Very broadly, the better (i.e. lower) the U-value of a building's fabric, the less energy is required to maintain comfortable conditions inside the building. As energy prices increase, and there is greater awareness of sustainability, performance measures such as U-values have become more important, and building standards (such as the Building Regulations) have required that lower and lower U-values are achieved. This has required changes in the design of buildings, both in the use of materials (such as insulation), the make-up of the building elements (such as cavity walls and double glazing), and the overall make up of a building's fabric (for example, reducing the proportion of glazing).
[edit] What is the difference between a U-value and an R-values?
R-values, which measure thermal resistance rather than thermal transmission, are often described as being the reciprocal of U-values, however, R-values do not include surface heat transfers.
[edit] What are the U-values of commonly building components?
U-values are measured in watts per square metre per kelvin (W/(m²K)). For example, a double glazed window with a U-value of 2.8, means that for every degree difference in temperature between the inside and outside of the window, 2.8 watts will be transmitted every square metre.
A range of typical U-values are:
- Solid brick wall: 2 W/(m²K)
- Cavity wall with no insulation: 1.5 W/(m²K).
- Insulated wall: 0.18 W/(m²K).
- Single glazing: 4.8 to 5.8 W/(m²K).
- Double glazing: 1.2 to 3.7 W/(m²K) depending on type.
- Triple glazing below: 1 W/(m²K).
- Solid timber door: 3 W/(m²K).
It is important to distinguish between U-values for materials (such as glass), or assemblies (such as windows, which have frames, air gaps, and so on), or elements (such as walls, which may have complex constructions comprising a number of different components).
[edit] What are the maximum U-values allowed?
Part L of the Building Regulations (Conservation of fuel and power) now prevents certain forms of construction by setting limiting standards (i.e. maximum U-values) for building elements. See Limiting fabric parameters for more information.
It should be noted however that these are maximum permitted values, the specification for the notional domestic building referred to in Part L1A has considerably lower values, for example:
- External wall: 0.18 W/(m²K).
- Floor: 0.13 W/(m²K).
- Roofs: 0.13 W/(m²K).
- Windows, roof windows, glazed rooflights and glazed doors: 1.4 W/(m²K).
See Standard Assessment Procedure SAP for more information.
[edit] How are U-values calculated?
The U value of an element (in W/(m²K)) can be calculated from sum of the thermal resistances (R-values in m²K/W) of the layers that make up the element plus its inside and outside surface thermal resistances (Ri and Ro).
U-value = 1 / (ΣR + Ri + Ro)
Where the thermal resistance of the layers of the element R = the thickness of each layer / the thermal conductivity of that layer (its k-value or lambda value (λ) in W/(mK)).
This can become a complicated calculation when there are a large number of layers, ventilated or unventilated cavities are introduced, or the element is inclined. Manufacturers will generally provide U-values for products that they supply. There are also a number of U-value calculators available online.
Calculation methods for U-values appropriate for demonstrating compliance with the building regulations are based on standards developed by the European Committee for Standardisation (CEN) and the International Organisation for Standardisation (ISO) and published as British Standards.
Whilst U-values are still used in the Building Regulations to set limiting standards for the elements of a building's fabric, the overall thermal performance of buildings is now assessed using more complex modelling procedures.
For non-domestic buildings, the Simplified Building Energy Model (SBEM) developed by the BRE for the Department for Communities and Local Government, determines the energy performance of a proposed building by comparing its annual energy use with that of a comparable notional building.
For dwellings, energy performance is assessed using the Standard Assessment Procedure (SAP).
NB: Whilst U-values and methods of modelling the thermal performance of buildings are invaluable in setting standards and providing a means of comparing alternative solutions, they are simplifications of reality, and performance in use rarely matches that which was predicted. Poor workmanship can result in reduced thermal resistance, as can poor detailing and the presence of water in insulating materials. See Insulation specification and performance gap for more information.
[edit] Related articles on Designing Buildings
- Air tightness in buildings.
- Building performance.
- Cavity wall insulation.
- Conduction.
- Conventions for calculating linear thermal transmittance and temperature factors.
- Conventions for U-value calculations (BR443 2e 2019).
- Double glazing v triple glazing.
- Emissivity.
- Free U-value calculators.
- g-value.
- k-value.
- Heat loss.
- Heat transfer.
- Insulation.
- Limiting fabric parameters.
- R-value.
- Standard Assessment Procedure SAP.
- Thermal admittance.
- Thermal bridge.
- Thermal mass.
- Thermal resistance.
- U-value conventions in practice: Worked examples using BR 443.
- U-What?
- What do design professionals need to know about U-value calculation conventions?
[edit] External references
Featured articles and news
Deputy editor of AT, Tim Fraser, discusses the newly formed society with its current chair, Chris Halligan MCIAT.
Barratt Lo-E passivhaus standard homes planned enmasse
With an initial 728 Lo-E homes across two sites and many more planned for the future.
Government urged to uphold Warm Homes commitment
ECA and industry bodies write to Government concerning its 13.2 billion Warm Homes manifesto commitment.
Places of Worship in Britain and Ireland, 1929-1990. Book review.
The emancipation of women in art.
CIOB Construction Manager of the Year 2025
Just one of the winners at the CIOB Awards 2025.
Call for independent National Grenfell oversight mechanism
MHCLG share findings of Building Safety Inquiry in letter to Secretary of State and Minister for Building Safety.
The Architectural Technology Awards
AT Awards now open for this the sixth decade of CIAT.
50th Golden anniversary ECA Edmundson awards
Deadline for submissions Friday 30 May 2025.
The benefits of precast, off-site foundation systems
Top ten benefits of this notable innovation.
Encouraging individuals to take action saving water at home, work, and in their communities.
Takes a community to support mental health and wellbeing
The why of becoming a Mental Health Instructor explained.
Mental health awareness week 13-18 May
The theme is communities, they can provide a sense of belonging, safety, support in hard times, and a sense purpose.
Mental health support on the rise but workers still struggling
CIOB Understanding Mental Health in the Built Environment 2025 shows.
Design and construction material libraries
Material, sample, product or detail libraries a key component of any architectural design practice.
Construction Products Reform Green Paper and Consultation
Still time to respond as consultation closes on 21 May 2025.
Resilient façade systems for smog reduction in Shanghai
A technical approach using computer simulation and analysis of solar radiation, wind patterns, and ventilation.
Comments
[edit] To make a comment about this article, or to suggest changes, click 'Add a comment' above. Separate your comments from any existing comments by inserting a horizontal line.