[edit] What are U-values?
U-values (sometimes referred to as heat transfer coefficients or thermal transmittances) are a measure of how effective the elements of a building's fabric are as insulators. That is, the degree to which they prevent heat from transmitting between the inside and the outside of a building.
The lower the U-value of an element of a building's fabric, the more slowly heat is able to transmit through it, and so the better it performs as an insulator.
Very broadly, the better (i.e. lower) the U-value of a building's fabric, the less energy is required to maintain comfortable conditions inside the building. As energy prices increase, and there is greater awareness of sustainability, performance measures such as U-values have become more important, and building standards (such as the Building Regulations) have required that lower and lower U-values are achieved. This has required changes in the design of buildings, both in the use of materials (such as insulation), the make-up of the building elements (such as cavity walls and double glazing), and the overall make-up of a building's fabric (for example, reducing the proportion of glazing).
[edit] What is the difference between a U-value and an R-value?
R-values, which measure thermal resistance rather than thermal transmission, are often described as being the reciprocal of U-values, however, R-values do not include surface heat transfers.
[edit] What are typical U-values for common building components?
U-values are measured in watts per square metre per kelvin (W/(m²K)). For example, a double glazed window with a U-value of 2.8, means that for every degree difference in temperature between the inside and outside of the window, 2.8 watts will be transmitted every square metre.
A range of typical U-values are:
- Solid brick wall: 2 W/(m²K).
- Cavity wall with no insulation: 1.5 W/(m²K).
- Insulated wall: 0.18 W/(m²K).
- Single glazing: 4.8 to 5.8 W/(m²K).
- Double glazing: 1.2 to 3.7 W/(m²K) depending on type.
- Triple glazing: below 1 W/(m²K).
- Solid timber door: 3 W/(m²K).
It is important to distinguish between U-values for materials (such as glass), or assemblies (such as windows, which have frames, air gaps, and so on), or elements (such as walls, which may have complex constructions comprising a number of different components).
[edit] What are the maximum U-values allowed?
Part L of the Building Regulations (Conservation of fuel and power) prevents certain forms of construction by setting limiting standards (i.e. maximum U-values) for building elements. See Limiting fabric parameters for more information.
It should be noted however that these are maximum permitted values; the specification for the notional dwelling referred to in Approved Document L, Volume 1 (2021 edition, incorporating 2023 amendments) has considerably lower values, for example:
- External wall: 0.18 W/(m²K).
- Floor: 0.13 W/(m²K).
- Roof: 0.11 W/(m²K).
- Windows, roof windows, glazed rooflights and glazed doors: 1.2 W/(m²K).
See Standard Assessment Procedure SAP for more information.
The Future Homes Standard, published in March 2026, comes into force on 24 March 2027, with a 12-month transitional period allowing projects with applications already submitted to be built to the current Part L 2021 standards, provided work commences by 24 March 2028 (higher-risk buildings have a later compliance date of 24 September 2027). The notional dwelling specification under the Future Homes Standard carries forward broadly the same fabric U-values as the current uplift, but tightens the assumed airtightness standard from 5 to 4 m³/(h·m²) at 50 Pa, and introduces mandatory solar photovoltaic panels and low-carbon heating, effectively ending the installation of gas boilers in new homes.
[edit] How are U-values calculated?
The U value of an element (in W/(m²K)) can be calculated from the sum of the thermal resistances (R-values in m²K/W) of the layers that make up the element plus its inside and outside surface thermal resistances (Ri and Ro).
U-value = 1 / (ΣR + Ri + Ro)
Where the thermal resistance of the layers of the element R = the thickness of each layer / the thermal conductivity of that layer (its k-value or lambda value (λ) in W/(mK)).
This can become a complicated calculation when there are a large number of layers, ventilated or unventilated cavities are introduced, or the element is inclined. Manufacturers will generally provide U-values for products that they supply. There are also a number of U-value calculators available online.
Calculation methods for U-values appropriate for demonstrating compliance with the building regulations are based on standards developed by the European Committee for Standardisation (CEN) and the International Organisation for Standardisation (ISO) and published as British Standards, such as BS EN ISO 6946.
Whilst U-values are still used in the Building Regulations to set limiting standards for the elements of a building's fabric, the overall thermal performance of buildings is assessed using more complex modelling procedures.
For non-domestic buildings, the Simplified Building Energy Model (SBEM), developed by the BRE, is used within the National Calculation Methodology (NCM) to determine the energy performance of a proposed building by comparing its annual energy use with that of a comparable notional building. A Future Buildings Standard, the non-domestic equivalent of the Future Homes Standard, is also being developed.
For dwellings, energy performance is currently assessed using the Standard Assessment Procedure (SAP), version 10.3. The government's new Home Energy Model (HEM) is expected to become an approved alternative to SAP from around mid-2026, with a dual-running period of at least 24 months before HEM eventually replaces SAP entirely as the methodology used to demonstrate compliance with the Future Homes Standard.
NB: Whilst U-values and methods of modelling the thermal performance of buildings are invaluable in setting standards and providing a means of comparing alternative solutions, they are simplifications of reality, and performance in use rarely matches that which was predicted. Poor workmanship can result in reduced thermal resistance, as can poor detailing and the presence of water in insulating materials. See Insulation specification and performance gap for more information.
[edit] Related articles on Designing Buildings
- Air tightness in buildings.
- Building performance.
- Cavity wall insulation.
- Conventions for calculating linear thermal transmittance and temperature factors.
- Conventions for U-value calculations (BR443 2e 2019).
- Double glazing v triple glazing.
- Free U-value calculators.
- g-value.
- k-value.
- Heat loss.
- Heat transfer.
- Insulation.
- Limiting fabric parameters.
- R-value.
- Standard Assessment Procedure SAP.
- Thermal bridge.
- Thermal mass.
- Thermal resistance.
- U-value conventions in practice: Worked examples using BR 443.
- What do design professionals need to know about U-value calculation conventions?
[edit] External references
- Planning Portal: Approved Document L, Volume 1: Dwellings.
- GOV.UK: Conservation of fuel and power: Approved Document L.
- GOV.UK: Standard Assessment Procedure.
- BRE: Conventions for U-value calculations (2006 edition; archived).
- BRE U-value calculator (archived).
- National Calculation Methodology website (archived).
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Building Safety Regulator, 19 August
Gill Kernick appointed Independent Chair of Residents’ Panel.
Connecting knowledge, technology and conservation
Building competence for the future of built heritage.
Building Regulations and Building Safety Act
CIOB publishes free advice for non-domestic clients.
Building Safety Newsletter from MHCLG.
An extraordinary record of steel engineering worldwide.
Households living near new pylons to save on bills.
ECA warns growth must not outpace grid capacity or skills.
The role of the client and decision making
CIOB response to built environment professions call for evidence.
Construction's sustainability reporting revolution
Tracking upfront embodied carbon with digital tools.
ECA welcomes procurement reforms
Public spending must back British jobs and skills.
Campaigning for Edinburgh: the Cockburn Association 1875-2049
The role of the civic voice in protecting character. Book review.
CIOB photography competition is open for entries.



















Comments
[edit] To make a comment about this article, or to suggest changes, click 'Add a comment' above. Separate your comments from any existing comments by inserting a horizontal line.