Limiting fabric standards
Contents |
[edit] Introduction
The building regulations require that reasonable provision be made to limit heat gains and losses through the fabric of new buildings and works to existing buildings. The approved documents to the buildings regulations set out the limiting standards for the properties of the fabric elements of the building.
[edit] L1A, new dwellings, 2013 edition
| Roof | 0.2 W/(m^2K) |
| Wall | 0.3 W/(m^2K) |
| Floor | 0.25 W/(m^2K) |
| Party wall | 0.2 W/(m^2K) |
| Swimming pool basin | 0.25 W/(m^2K) |
| Windows, roof windows, glazed roof-lights, curtain walling and pedestrian doors | 2.0 W/(m^2K) |
| Air permeability | 10.0 m^3/(h.m^2) at 50 Pa |
[edit] L2A, new buildings other than dwellings, 2013 edition
| Roof | 0.25 W/(m^2K) |
| Wall | 0.35 W/(m^2K) |
| Floor | 0.25 W/(m^2K) |
| Swimming pool basin | 0.25 W/(m^2K) |
| Windows, roof windows, roof-lights, curtain walling and pedestrian doors | 2.2 W/(m^2K) |
| Vehicle access and similar large doors | 1.5 W/(m^2K) |
| High-usage entrance doors | 3.5 W/(m^2K) |
| Roof ventilators (inc. smoke vents) | 3.5 W/(m^2K) |
| Air permeability | 10.0 m^3/(h.m^2) at 50 Pa |
[edit] L1B and L2B, existing dwellings and existing buildings other than dwellings, 2010 editions
| New thermal elements | Retained thermal elements | |
| Wall | 0.28 W/(m^2K) | |
| Pitched roof – insulation at ceiling level | 0.16 W/(m^2K) | 0.16 W/(m^2K) |
| Pitched roof – insulation at rafter level | 0.18 W/(m^2K) | 0.18 W/(m^2K) |
| Flat roof or roof with integral insulation | 0.18 W/(m^2K) | 0.18 W/(m^2K) |
| Floors | 0.22 W/(m^2K) | 0.25 W/(m^2K) |
| Swimming Pool basin | 0.25 W/(m^2K) | |
| Wall – cavity insulation | 0.55 W/(m^2K) | |
| Wall – external or internal insulation | 0.30 W/(m^2K) |
NB Approved Document C gives limiting values for individual elements to minimise the risk of condensation.
[edit] Related articles on Designing Buildings Wiki
- 2013 changes to the approved documents for part L of the building regulations
- Approved documents.
- Building Regulations.
- PA ratio.
- Part L.
- U-value.
[edit] External references
- Approved Document L1A: Conservation of fuel and power in new dwellings, 2013 edition.
- Approved Document L2A: Conservation of fuel and power in new buildings other than dwellings, 2013 edition.
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Your guide to The Construction Reset at UKCW Birmingham.
Accommodating the Victorian and Edwardian working woman. Book review.
Rethinking passive fire protection in design
PFP demands the same level of design rigour as structure or services.
38% of Gen Zs feel safe when a fire door is wedged open.
Stunning images from around the world
Shortlist for CIOB’s Art of Building photography competition.
Guidance for conversion of traditional pre-1919 stone buildings.
Industrial heritage in the Ruhr
A marked difference to the fate of industrial landscapes in the UK.
Communities will be able to build their own clean energy.
Why diversity and inclusion matters for SMEs
CIOB’s D&I Charter shows how practical changes can support long-term growth.
Cut electricity bills to power growth
Coalition sends joint letter to the Chancellor.
Gasholders: a history in pictures. Book review.
Recognition, influence and growth
SocEnv identifies three strategic pillars in new strategy to 2045.