Conoid shell
A conoid is a special kind of warped ruled surface which, as a curved shell roof, can be used as an alternative to a barrel vault. The basic principle is that one edge of the shell is curved while the opposite edge is kept straight. In architecture, this is referred to as a ‘right conoid’.
Two basic geometrical forms are encountered:
- A straight line is moved along a curved line at one end and a straight line at the other end, the resultant shape being cut to the required length.
- A straight line is moved along a curved line at one end and a different curved line at the other end.
The end consists of a reinforced concrete or steel lattice, which serves as a stiffening beam to prevent shell deformation. Support is required at all corners.
Spans of up to 12 m with chord lengths of up to 24 m are possible. The typical chord-to-span ratio is 2:1.
When conoids are made of reinforced concrete they require formwork on which to set the reinforcing steel and pour the concrete. The initial cost of making the formwork is usually high, but it can be reduced by pouring many shells on the same form.
There can be a solid infill or glazed end diaphragm. Glass panes set between adjacent conoids at the curved front of each conoid can allow for illumination. If the conoids face north they get the best natural light, which can be important for space such as factories.
Conoid shells are an ideal shape for cantilevered roofs covering the stands of stadiums with either a curvature up or a curvature down.
[edit] Find out more
[edit] Related articles on Designing Buildings Wiki
- Anticlastic.
- Barrel vault.
- Cantilever.
- Folded plate construction.
- Hyperbolic paraboloid.
- Long span roof.
- Megastructure.
- Pendentive dome.
- Portal frame.
- Shell roof.
- Suspended ceiling.
- Synclastic.
- Tensile structures.
- Types of ceiling.
- Types of dome.
- The history of fabric structures.
[edit] External references
- ‘Building Construction Handbook’ (6th ed.), CHUDLEY, R., GREENO, R., Butterworth-Heinemann (2007)
- ‘The story of a right wavelet conoid’ , J. Dolezal (2011)
Synclastic.
Featured articles and news
We're expanding our collaborative mission by launching DB Intelligence, an exclusive market research advisory panel. Built environment professionals can now get paid to share their expertise on industry trends, products and services.
Panel members receive direct financial incentives for participating in research projects like short surveys, 1-2-1 interviews and focus groups. Register today to shape the future of the construction sector.
Building Control Independent Panel final report
A precis of a key report led by Dame Hackitt with full recommendations and link to the government response.
Guide to ISO 19650 for Architecture Firms (2026)
A user gives their low down.
A UK training and membership provider for mould remediation professionals.
Building Safety recap April, 2026
A short and longer run-through of the month, with links to further information and sources.
CIAT May 2026 briefing.
Independent NSI and BAFE study exploring how organisations are changing the way they buy fire safety services.
From medieval scribes to modern word art.
ECA welcomes crackdown on late payment and push for clean energy, whilst CIOB seek fixed cladding removal timeframes.
Cyber Security in the Built Environment
Protecting projects, data, and digital assets: A CIOB Academy TIS.
Managing competence in the built environment
ITFG publishes new industry guide on how to meet the ICC principles.
The UK's campaign to reduce noise pollution: Mythbusting, articles and topic guides.