Thermal conductivity
[edit] Introduction
Thermal conductivity (sometimes referred to as k-value or lambda value (λ)) is a measure of the rate at which temperature differences transmit through a material. The lower the thermal conductivity of a material, the slower the rate at which temperature differences transmit through it, and so the more effective it is as an insulator. Very broadly, the lower the thermal conductivity of a building's fabric, the less energy is required to maintain comfortable conditions inside.
Thermal conductivity is a fundamental material property independent of thickness. It is measured watts per meter kelvin (W/mK).
The thermal resistance of the layers of the a building's fabric (R measured in in m²K/W) can be calculated from the thickness of each layer / the thermal conductivity of that layer.
The U value of an element of a building can be calculated from sum of the thermal resistances (R-values) of the layers that make up the element plus its internal and external surface resistances (Ri and Ro).
U-value = 1 / (ΣR + Ri + Ro)
U-values (sometimes referred to as heat transfer coefficients or thermal transmittances) are used to measure how effective elements of a buildings fabric are as insulators.
The standards for the measurement of thermal conductivity are BS EN 12664, BS EN 12667 and BS EN 12939. In the absence of values provided by product manufacturers following thermal conductivity tests, the thermal conductivity data obtained from BS EN 12524 Building materials and products. Hygrothermal properties.
[edit] Thermal conductivity of typical building materials
Thermal conductivity values of typical building materials shown below.
Material | W/mK |
Blockwork (light) | 0.38 |
Blockwork (medium) | 0.51 |
Blockwork (dense) | 1.63 |
Brick (exposed) | 0.84 |
Brick (protected) | 0.62 |
Chipboard | 0.15 |
Concrete (aerated) | 0.16 |
Concrete (cellular 400 kg/m3) | 0.1 |
Concrete (cellular 1200 kg/m3) | 0.4 |
Concrete (dense) | 1.4 |
fibreglass quilt | 0.033 |
glass | 1.05 |
glass foam aggregate (dry) | 0.08 |
hemp slabs | 0.40 |
hempcrete | 0.25 |
mineral wool | 0.038 |
mortar | 0.80 |
phenolic foam (PIR) | 0.020 |
plaster (gypsum) | 0.46 |
plasterboard (gypsum) | 0.16 |
polystyrene foam | 0.032 |
polyurethane foam (PUR) | 0.025 |
render (sand/cement) | 0.50 |
screed (cement/sand) | 0.41 |
steel | 16 - 80 |
stone (limestone) | 1.30 |
stone (sandstone) | 1.50 |
stone (granite) | 1.7 - 4.0 |
stone chippings | 0.96 |
straw bale | 0.09 |
timber (softwood) | 0.14 |
timber (hardwood - commonly used) | 0.14 - 0.17 |
woodfibre board | 0.11 |
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Electrotechnical excellence, now open for entries.
Net zero electricity grids BSRIA guide NZG 5/2024
Outlining the changes needed to transition to net zero.
CIOB Global Student Challenge 2024
Universitas Indonesia wins for second year running.
New project and cultural district described in detail.
The nature of EPCs, crticism and inaccuracies.
History, issues and redesign.
From waste recycling to energy performance the hierchy.
An introduction to WERCS and WEEE responsibilities
Dealing with 2 million tonnes of waste equipment a year.
Global BACS Market: analytics and optimisation
A BSRIA glance at building automation and control systems.
What it is and how to use it.
Types of insulating plaster by binder and insulant.
Investors in People: CIOB achieves gold
Reflecting a commitment to employees and members.
Scratching beneath the surface; a guide to selection.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
UK gov apprenticeship funding from April 2024
Brief summary the policy paper updated in March.
For the World Autism Awareness Month of April.
Comments
Thermal conductivity (often denoted k, λ, or κ) refers to the intrinsic ability of a material to transfer heat. It is evaluated primarily in terms of Fourier’s Law for heat conduction. https://thermtest.com/what-is-thermal-conductivity