How to correctly size an ambient loop heat network using diversity factors
Contents |
[edit] Introduction
As their name suggests, ambient loops operate at significantly lower temperatures than traditional communal high temperature heating systems. This means that a different approach is required when sizing the ambient loop distribution system. Calculation of such systems follows a procedure where diversity is used to determine the design flowrate for a development. It also determines the sizing of pipework and circulation pumps for an ambient communal network solution such as the Zeroth Energy System. The in-apartment flowrates required for the selected size of the Zeroth Heat Pumps can then be calculated.
The Zeroth Energy System uses an ambient communal water loop designed at 25°C, and in-apartment water-to-water heat pumps to provide space heating, comfort cooling and hot water. The system has been successfully installed and set to work in numerous projects across the UK. These installations are demonstrating that by reducing the temperature in the energy loop, the Zeroth Energy System can help resolve challenges associated with plant fuel source, plant and riser space, and heat loss into communal spaces. Heat distribution losses are one of the main causes of low system efficiency traditional communal heating systems that use centralised boiler systems suffer from, and issue which can be fundamentally addressed through the application of ambient distribution solutions.
The ‘Design Guide for Diversity Factors for Ambient Temperature Networks using the Zeroth Energy System’ was created by a global provider of technology testing and certification, TÜV SÜD, in association with Wallace Whittle, and offers guidance regarding the correct sizing of ambient networks using diversity factors.
[edit] How can we use diversity factors to determine the design flowrate for a development?
Once the correctly sized Zeroth Heat Pumps are selected, the design flow rate of the system can be calculated as:
Mass flowrate (kg/s) = total loop load (kW) ÷ (ΔT x Cp)
The ΔT is the temperature difference between flow and return, which for the Zeroth Energy System stands at 5k. The Cp refers to the Specific Heat Capacity of water (4.18 kJ/(kg*K) at 25°C).
To complete the calculation, the total diversified peak load of the development is required. This will be the sum of all Zeroth Heat Pump duties:
Total Peak Load = (Space heating diversity x Total apartments heating load) +(Hot water diversity x Sum of Zeroth Heat Pump Duties.)
You can read more on how to apply diversity to define peak hot water needs here. The total peak load calculation should include any systems connecting into the ambient loop from any part of the development, such as apartments, communal areas, commercial spaces. If cooling is supplied by the Zeroth Energy System, the total cooling load of a building, including any non-residential space, must be included.
The total loop load needed for the mass flow rate can now be calculated:
Total heat input from central plant (total loop load) = (Space heating diversity x Total energy extracted from loop in heating mode) + (Hot water diversity x Total energy extracted from loop in HWC* reheat mode.)
The loop load is the energy required from the ambient loop by each of the Zeroth Heat Pumps. You can read more on how diversity calculation is applied to HVAC systems and how it can shape the HVAC specification for residential developments here.
[edit] Sizing pipework and ambient loop circulation pump
Like traditional communal heating system designs, the ambient loop of the Zeroth Energy System uses water as a distribution medium through pressurised plastic or steel pipework. The electrical energy required for pumping is the driving factor when selecting the pipe sizing for an ambient loop. Pipe sizing away from the index run can differ if required. Reference should be made to CIBSE Guide C for guidance on velocity and pressure drop limits.
The ambient loop circulation pump size will be determined by the flowrates on the index run and can be calculated using software or spreadsheets to achieve the minimum required flowrate. Correct calculations will help avoid oversizing of circulation pumps that can lead to lower operational efficiency.
[edit] Related articles on Designing Buildings
Featured articles and news
Places of Worship in Britain and Ireland, 1929-1990. Book review.
The emancipation of women in art.
CIOB Construction Manager of the Year 2025
Just one of the winners at the CIOB Awards 2025.
Call for independent National Grenfell oversight mechanism
MHCLG share findings of Building Safety Inquiry in letter to Secretary of State and Minister for Building Safety.
The Architectural Technology Awards
AT Awards now open for this the sixth decade of CIAT.
50th Golden anniversary ECA Edmundson awards
Deadline for submissions Friday 30 May 2025.
The benefits of precast, off-site foundation systems
Top ten benefits of this notable innovation.
Encouraging individuals to take action saving water at home, work, and in their communities.
Takes a community to support mental health and wellbeing
The why of becoming a Mental Health Instructor explained.
Mental health awareness week 13-18 May
The theme is communities, they can provide a sense of belonging, safety, support in hard times, and a sense purpose.
Mental health support on the rise but workers still struggling
CIOB Understanding Mental Health in the Built Environment 2025 shows.
Design and construction material libraries
Material, sample, product or detail libraries a key component of any architectural design practice.
Construction Products Reform Green Paper and Consultation
Still time to respond as consultation closes on 21 May 2025.
Resilient façade systems for smog reduction in Shanghai
A technical approach using computer simulation and analysis of solar radiation, wind patterns, and ventilation.
Digital technology, transformation and cybersecurity
Supporting SMEs through Digitalisation in Construction.
Villa Wolf in Gubin, history and reconstruction. Book review.
Construction contract awards down one billion pounds
Decline over the past two months compared to the same period last year, follows the positive start to the year.
Editor's broadbrush view on forms of electrical heating in context.