[edit] Introduction
Tanking is a term used for creating a tank-like seal to protect walls against water penetration. The Building Regulations stipulate that tanking must be applied to all new build structures below ground, but tanking can also be applied to existing buildings, to prevent water penetration into basements and cellars, as well as helping to tackle rising damp.
The two main methods of tanking are by using a membrane or a coating. The type of damp and the precise requirements of the building will determine the most appropriate method to use, and sometimes a combination is required to ensure walls remain dry.
[edit] Tanking membranes
Tanking membranes (or cavity drain membranes) consist of a studded or dimpled plastic sheet which is fixed onto the internal face of masonry, block or rendered walls and sealed with tape.
The studs create an air gap cavity between the wall and membrane. Where there is no visible water in the cavity, ventilation may be adequate to prevent the accumulation of moisture. Where water is present, drainage or a or sump and pump may be necessary.
Tanking membranes can have a plain surface which allows battening and insulation boards to be attached to them, or a mesh surface for direct plastering.
[edit] Coating
Tanking coatings include; bitumen, asphalt, resin/tar and tanking slurry.
Liquid bitumen is painted onto cleaned masonry or render but is best for smaller jobs or for coating externally below the damp-proof course. It can prove difficult to apply to masonry in older buildings as it can separate from the wall if applied incorrectly.
Resin/tar coatings are typically epoxy or polyurethane resins extended with tar or bitumen. They are generally able to withstand higher pressures than bitumen coatings.
Asphalt is typically applied in a thick coat with a further wall constructed to prevent it from delaminating under water pressure.
Cement based tanking slurry is typically used for larger areas. It can be applied with a brush, and once dry, overcoated with a breathable render and finished with plasterboard or plaster.
Both floors and walls may require tanking to prevent water ingress.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
From Chaucer to Fawlty Towers.
Electrotechnical excellence, now open for entries.
Net zero electricity grids BSRIA guide NZG 5/2024
Outlining the changes needed to transition to net zero.
CIOB Global Student Challenge 2024
Universitas Indonesia wins for second year running.
New project and cultural district described in detail.
The nature of EPCs, crticism and inaccuracies.
History, issues and redesign.
From waste recycling to energy performance the hierchy.
An introduction to WERCS and WEEE responsibilities
Dealing with 2 million tonnes of waste equipment a year.
Global BACS Market: analytics and optimisation
A BSRIA glance at building automation and control systems.
What it is and how to use it.
Types of insulating plaster by binder and insulant.
Investors in People: CIOB achieves gold
Reflecting a commitment to employees and members.
Scratching beneath the surface; a guide to selection.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
UK gov apprenticeship funding from April 2024
Brief summary the policy paper updated in March.
Comments
It is clearly stated in British Standard 8102 for below ground structures, that Cavity Drain Membranes ARE NOT tanking. they are good repair products but must not be the primary water proofing system in a new build they can make a Type A or B water proofing systems can create a tanked area.
Regards