Drainage stack
The term ‘drainage stack’ or ‘drain stack’ is commonly used in the United States, and sometimes in commercial construction in the UK.
In very broad terms, it refers to a vertical pipe or stack that spans through one or more floors and into which drains from a property are connected to take waste water to a sewer. Branch drains run relatively horizontally from water closets, sinks, showers and so on to the vertical drainage stack which then connects to a relatively horizontal sewer at its lowest point. It may be referred to as a vent stack above the point that drains connect to it, as a drain stack below the point at which waste water drains into it and as a soil stack below the point at which sewage drains into it.
In the UK, particularly in domestic construction, it may be referred to as a soil vent pipe (SVP). Soil vent pipes allow the removal of waste from toilets, showers, baths, sinks and so on, while also allowing odours to be released above the building, via a stack vent, at a level that will not cause a nuisance. The pipe’s vent also allows air into the internal drainage system preventing a siphoning effect from occurring, and allowing free flow of waste water by gravity. An SVP may also be described as a soil stack pipe, drain waste vent or ventilated discharge pipe and is often seen on an outside wall of domestic buildings, but may be located internally.
For more information see: Soil vent pipe.
When installing drainage and ventilation pipework in high-rise buildings, traditional design standards dictate that a secondary ventilation stack has to be used to overcome air pressure changes. However, products such as the Polypipe Terrain P.A.P.A® and Pleura valves are a proven alternative to traditional secondary vented drainage systems. The P.A.P.A® (positive air pressure attenuation) valve is designed to react to and attenuate positive pressure transience within the drainage stack of high-rise developments providing a suitable venting solution for any multi-storey building.
For more information see: Secondary Ventilation Stacks in Tall Buildings.
[edit] Related articles on Designing Buildings Wiki
- Air admittance valve.
- Drainage.
- Fabricated drainage stacks.
- Greywater.
- Pumps and dewatering equipment.
- Rain gutter.
- Rainwater.
- Rainwater goods.
- Rainwater downpipe.
- Sanitary pipework.
- Secondary Ventilation Stacks in Tall Buildings.
- Sewer construction.
- Soil vent pipe.
- Soakaway.
- Sustainable urban drainage systems SUDS.
- Vacuum breaker.
- Wellpoint.
Featured articles and news
Not buildings. Happy holiday from DB.
Future Homes Standard: Industry calls for more ambition
As the Government FHS consultation finally closes.
Improving government projects with data and AI
Enabling better outcomes, efficient modern delivery and influential leadership on government projects.
BSRIA Living Laboratory Innovation Challenge
Final days for submission, closing March 29.
Windows, their frames, forms, factors and functions.
The hidden subtleties of U-Value calculations
Different contexts and what to include as variables.
A brief run down with related articles.
Electrical sector calls for safer public EV charge points
Serious concerns about electrical safety in the public domain.
Building Blocks manifesto presented to parliament
Architects Declare call in for support of five critical policies.
The four elements of project management with APM
Analysis, expectations, collaborative communication and partnerships.
City of London launches Heritage Building Retrofit Toolkit
Empowering owners to initiate necessary adaptations.
Guidance on RAAC in listed buildings
Published by Purcell, endorsed by IHBC, SPAB and C20.
Learning from the past.
Reluctance to hire people with criminal convictions revealed
Employing People with Criminal Convictions Report.
Tackling unconscious bias; Women's History Month
Personal reflections, as the last week of March approaches.