Non-destructive testing
RAAC playbook, published by the Manufacturing Technology Centre and the High Value Manufacturing Catapult in 2024 defines non-destructive testing (NDT) as: ‘a method of testing something that does not damage it. NDT is also known as non-destructive examination (NDE), non-destructive inspection (NDI) and non-destructive evaluation.’
It refers to a range of techniques used to inspect and assess the integrity, quality, and performance of materials, components, or structures without causing damage. This approach ensures that the tested item remains fully functional and can continue to be used after inspection, which is particularly important in construction for maintaining safety and avoiding costly repairs.
Non-destructive testing avoids the need for destructive testing and costly repairs. Inspections can often be performed on-site with minimal disruption, which reduces waste and preserves resources by prolonging the life of materials and structures. It can help ensure the safety of workers and other users by identifying potential issues early.
Applications include:
- Structural Integrity Checks: Inspecting bridges, buildings, and other critical infrastructure for hidden defects.
- Quality Assurance: Ensuring materials and workmanship meet regulatory and safety standards.
- Maintenance: Monitoring the health of structures to prevent failures and plan repairs proactively.
- Compliance: Supporting adherence to UK building regulations and codes.
Common techniques include:
- Ultrasonic Testing (UT): This uses high-frequency sound waves to detect internal flaws or measure material thickness. It is commonly used for weld inspections, concrete evaluation, and metal structures.
- Radiographic Testing (RT): Employs X-rays or gamma rays to create images of the internal structure of a component. This can be useful for identifying cracks, voids, or other internal defects in welds, concrete, and metal parts.
- Magnetic Particle Testing (MPT): Detects surface and near-surface defects in ferromagnetic materials. A magnetic field is applied, and particles are used to reveal flaws.
- Dye Penetrant Testing (DPT): Applies a liquid dye to the surface to identify cracks or defects visible to the naked eye. Suitable for non-porous materials like metal, plastic, and ceramics.
- Visual Inspection (VI): The simplest form of NDT, involving a trained inspector examining structures for visible signs of damage or irregularities. Often combined with other NDT methods for more comprehensive results.
- Ground Penetrating Radar (GPR): Used to assess subsurface conditions, locate utilities, or detect voids and defects in concrete or soil.
- Acoustic Emission Testing (AET): Monitors the release of sound waves caused by sudden material stress or crack formation.
- Infrared Thermography: Uses thermal imaging to detect temperature variations that may indicate insulation issues, moisture intrusion, or structural weaknesses.
[edit] Related articles on Designing Buildings
Featured articles and news
Futurebuild and UK Construction Week London Unite
Creating the UK’s Built Environment Super Event and over 25 other key partnerships.
Welsh and Scottish 2026 elections
Manifestos for the built environment for upcoming same May day elections.
Advancing BIM education with a competency framework
“We don’t need people who can just draw in 3D. We need people who can think in data.”
Guidance notes to prepare for April ERA changes
From the Electrical Contractors' Association Employee Relations team.
Significant changes to be seen from the new ERA in 2026 and 2027, starting on 6 April 2026.
First aid in the modern workplace with St John Ambulance.
Ireland's National Residential Retrofit Plan
Staged initiatives introduced step by step.
Solar panels, pitched roofs and risk of fire spread
60% increase in solar panel fires prompts tests and installation warnings.
Modernising heat networks with Heat interface unit
Why HIUs hold the key to efficiency upgrades.
Reflecting on the work of the CIOB Academy
Looking back on 2025 and where it's going next.
Procurement in construction: Knowledge hub
Brief, overview, key articles and over 1000 more covering procurement.
Sir John Betjeman’s love of Victorian church architecture.
Exchange for Change for UK deposit return scheme
The UK Deposit Management Organisation established to deliver Deposit Return Scheme unveils trading name.
A guide to integrating heat pumps
As the Future Homes Standard approaches Future Homes Hub publishes hints and tips for Architects and Architectural Technologists.
BSR as a standalone body; statements, key roles, context
Statements from key figures in key and changing roles.
Resident engagement as the key to successful retrofits
Retrofit is about people, not just buildings, from early starts to beyond handover.





















