How chimneys and flues work
A chimney and flue is a structure, also referred to as a chimney stack, often part of a building, sometimes separate or installed as an additional element or self-supporting tube (can be just referred to just as a flue, such as a gas flue). The hollow void within the brick, stone, concrete, metal, or prefabricated chimney is technically referred to as the flue. The flue connects to a combustible heat source, such as the combustion of gas in a gas boiler or solid fuel used in open fireplaces, wood-burning stoves, and biomass boilers.
The chimney in combination with the flue, removes exhaust fumes, or smoke, from the place of combustion, and away from the internal spaces being heated. It draws pollutants through a wall to the structure at the side of the building or running up through the roof into the upper air surrounding the building, and into the atmosphere. In many cases, a cap, cowl, wind cowl or just two leaning slates, located on top of the chimney prevents wind from blowing downward, which can hinder the exhausts from leaving the chimney.
Today the term chimney might be used to describe its role in other tasks that help service a buildings, often relating to ventilation such: A solar chimney (or thermal chimney) is design feature that supports passive climate design by using the suns heat to warm air at the top of a void, thus drawing it from the building and drawing fresh air in at low levels. A ventilation chimney is usually a small stack with a vent to help extract stale air from a building either passively or with the assistance of a fan. In some cases a wind cowl has been used to help pull air from a building, and exchanging its heat with incoming fresh air, prewarming it and reducing heating costs.
Because historically most buildings had chimneys and fireplaces were of the heart of many a home life, they often became architectural features throughout different eras such as Romanesque, Tudor and French Renaissance architecture. Some famous expressive chimneys might be those on the buildings of Antonio Gaudi in Barcelona, or the English, Thornbury castle, with ornate carved decorative brick symmetrical chimneys, or the Chateau of Chambord, famed for having 365 differently sculpted chimneys or one of the earliest examples, as well as the 12th-century abbey of Henry II at Fontevrault, where fireplaces merge to create a sculpted roof connecting some 20, pointed stone chimneys.
Chimneys function because hot air rises, so the hot exhaust gases create a pressure difference between the flue inside the chimney and the room. This pressure difference causes the fire to draw (or create a draft), which means warm air is pulled up through the chimney, drawing or pulling air from a vent or the room to feed the combustion (requiring oxygen), which then heats and is pulled up the chimney along with the exhaust gases in a continual cycle as the fire burns. Controlling the level of fuel and the rate at which oxygen is fed to the fire helps control the rate and temperature of combustion.
The warm exhausts from a chimney rise upwards until cooling, at which point the pollutants within the exhaust spread out, gradually mix with the air, and become part of the atmosphere. At relatively low levels, the pollutants from chimneys and flues are diluted by the surrounding air and become less harmful, though increased concentrations are problematic, and extreme levels can cause smog. Smog is a low-level dense cloud caused by high levels of pollutants in the air. Smog occurs when water vapour 'sticks' to the particulates released by burning fuel, in particular standard coal. This reduces visibility and can cause health issues for those exposed at the ground level.
Featured articles and news
Combating burnout.
The 5 elements of seiri, seiton, seiso, seiketsu and shitsuke.
Shading for housing, a design guide
A look back at embedding a new culture of shading.
The Architectural Technology Awards
The AT Awards 2025 are open for entries!
ECA Blueprint for Electrification
The 'mosaic of interconnected challenges' and how to deliver the UK’s Transition to Clean Power.
Grenfell Tower Principal Contractor Award notice
Tower repair and maintenance contractor announced as demolition contractor.
Passivhaus social homes benefit from heat pump service
Sixteen new homes designed and built to achieve Passivhaus constructed in Dumfries & Galloway.
CABE Publishes Results of 2025 Building Control Survey
Concern over lack of understanding of how roles have changed since the introduction of the BSA 2022.
British Architectural Sculpture 1851-1951
A rich heritage of decorative and figurative sculpture. Book review.
A programme to tackle the lack of diversity.
Independent Building Control review panel
Five members of the newly established, Grenfell Tower Inquiry recommended, panel appointed.
Welsh Recharging Electrical Skills Charter progresses
ECA progressing on the ‘asks’ of the Recharging Electrical Skills Charter at the Senedd in Wales.
A brief history from 1890s to 2020s.
CIOB and CORBON combine forces
To elevate professional standards in Nigeria’s construction industry.
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.