Volatile organic compounds VOC
Contents |
[edit] Introduction
Volatile organic compounds (VOCs) are organic chemicals that easily vaporise when they are at room temperature. At high levels in the air they can cause damage to human health or to the environment. They originate from a variety of classes of chemicals, including; alphatic, aromatic and halogenated hydrocarbons, aldehydes, ketones, ethers, esters, alcohols, acids and amines.
VOCs are common in industry, widely used in the petrochemical industries and as industrial cleaners and solvents. Other processes that emit VOCs include; printing, surface coating, chemical manufacturing, rubber fabrication, and wood and plastic lamination. In addition to the emissions through industry, VOCs can originate from households and from road transport.
[edit] Effects of VOCs
VOCs can result in harm in a number of ways:
- Direct damage to human health.
- Some VOCs can result in the generation of photochemical oxidants including ozone, in the lowest level of the atmosphere. They are commonly found at ground level close to urban and industrial centres and can contribute to elevated levels of ozone.
- Damage to the ozone layer at the level of the stratosphere.
- Contributing to global climate change.
- Causing offensive smells.
The inhalation of VOCs can cause a variety of health problems depending on the specific chemical and its toxicity.
Short-term exposure to high levels of VOCs can cause:
- Irritation to the eyes, nose or throat.
- Headaches.
- Nausea or vomiting.
- Dizziness.
- Exacerbating the symptoms of asthma.
Long-term exposure to high levels of VOCs can lead to an increased risk of:
[edit] Regulations
There are a variety of regulations in relation to VOCs, including:
- The Control of Substances Hazardous to Health (COSHH) Regulations 2002, which state that workers must be protected from the risks from hazardous substances such as VOC containing solvents.
- The Volatile Organic Compounds in Paints, Varnishes and Vehicle Refinishing Products Regulations 2012.
- The emission of VOCs from industrial processes are regulated under The Environmental Permitting (England and Wales) Regulations 2010. Permits specify the limits of emission and state that the concentration of the pollutant must not be in excess of a certain threshold or that the source must not release more than a certain mass of the pollutant over a set period of time.
NB According to the Home Quality Mark One, TVOC (Total VOC) is the sum of the concentrations of identified and unidentified volatile organic compounds eluting between and including n-hexane and n-hexadecane on a gas chromatographic column specified as a 5 % phenyl/95 % methyl-polysiloxane column. Ref BSI. 2015. BS EN 16516. Construction products – assessment of release of dangerous substances – determination of emissions into indoor air. 2015.
Total semi-volatile organic compound (TSVOC) is the: 'Sum of the concentrations of identified and unidentified volatile organic compounds eluting between nhexadecane (excluded) and n-docosane (included) on a gas chromatographic column specified as a 5% phenyl/95% methyl polysiloxane capillary column.' Ref BREEAM UK New Construction, Non-domestic Buildings (United Kingdom), Technical Manual, SD5078: BREEAM UK New Construction 2018 3.0, published by BRE Global Limited.
[edit] Related articles on Designing Buildings Wiki
- Adhesives.
- Asbestos.
- Binding agent.
- Construction dust.
- Contaminated land.
- Control of Substances Hazardous to Health.
- Deleterious materials.
- Environmental legislation.
- Environmental policy.
- Hazardous substances.
- Inspections focus on occupational lung disease.
- Planning (Hazardous Substances) Act 1990.
- Ozone depleting substances.
- Pollution.
- Structural adhesives.
- Workplace exposure limits.
[edit] External references
Featured articles and news
Corruption in the construction industry.
What will it take to stop it ?
To celebrate world bee day 2022 !
Just one month until the changes to part L come into effect.
Not forgetting part F and the new part overheating part O.
Heat Pump demand rises by one quarter.
As energy prices jump up in cost.
With people in the UK from Ukraine.
Industry leader Steve Murray takes on role.
An abundant and versatile building material.
How overheating complicates ending gas in the UK.
600,000 heat pump installations targeted per year by 2028.
Cost planning, control and related articles on DB.
Helping prevent those unwanted outcomes.
ICE debate Public transport - post pandemic.
How has transport changed due to Covid-19 ?
Cross-ventilation in buildings. Do you have it ?
Will you need it ? after June 15 and the new Part O ?
Share your knowledge with the industry.
Create an account and write the first of many articles.
The green jobs delivery group.
CIAT commentary after the first meeting.
Liverpool's world heritage site status
Who is to blame?
Research recommends focussing on portfolio success rather than project success.
ICE and BSI launch revised PAS 128 standard.
The revised standard for mapping underground utilities.
Launching the UK net zero carbon buildings standard.
Cross-industry steering group seeks support in delivery.