Low-e glass
The term ‘low-e glass’ is used to describe glass that has a coating added to one or more of its surfaces to reduce its emissivity.
Emissivity is an indicator of the amount of long-wave infra-red radiation which a surface (such as the façade of a building) will emit to its surroundings. According to Kirchoff's law the emissivity of a surface is equal to its radiant absorptivity at a given temperature and wavelength. It is expressed as a proportion of 1, so if a surface absorbs 40% of the long-wave infra-red radiation incident on its surface, it has an emissivity of 0.4.
All bodies which are hotter than 0°K emit thermal radiation and absorb thermal radiation. In general, the higher the temperature of a body, the lower the average wavelength of the radiation it emits. The range of terrestrial temperatures experienced within the built environment is comparatively ‘cold’ compared to the sun and so they are radiating at a much longer wavelength. This anomaly allows us to distinguish between short-wave solar radiation and long-wave infra-red radiation (terrestrial radiation).
Typically, glass is relatively transparent to short-wave solar radiation, but opaque to long-wave infra-red radiation. This is said to produce a ‘greenhouse effect’, where solar radiation enters a space, and heats it up, but the resulting long-wave infra-red radiation emitted by the hot internal surfaces is unable to escape.
However, glass has a relatively high emissivity. This means that although it does not transmit long-wave infra-red radiation incident on its surface, it does absorb it. This absorbed ‘heat’ is then re-radiated.
Low-e coatings can be used to reduce the effective emissivity of the surface of glass so that it reflects, rather than absorbs, a higher proportion of long-wave infra-red radiation.
In cooler climates this means that long-wave infra-red radiation that builds up inside a building is reflected by the glass back into the space, rather than being absorbed by the glass and then partially re-radiated to the outside. This reduces heat loss and so the need for artificial heating.
In hotter climates, a low-e coating means that long-wave infra-red radiation outside the building is reflected back out of the building, rather than being absorbed by the glass and then partially re-radiated to the inside. This reduces the heat build-up inside the building and so the need for cooling. In hotter climates, a low-e coating might be used in conjunction with solar-control glass to reduce the amount of short-wave solar radiation entering the building.
Low-e coatings can reduce the emissivity of glazing from more than 0.8 to 0.2 or even as low as 0.04. Coatings tend to be either hard ‘pyrolytic’ coatings which are applied to molten glass, or soft ‘sputtered’ coatings, which generally need to be protected within the sealed unit.
[edit] Related articles on Designing Buildings
- Angular selective shading systems.
- Brise soleil.
- Choosing the correct glazed facade heating system.
- Computational fluid dynamics (CFD).
- Curved glass.
- Double glazing.
- Double glazing v triple glazing.
- Emissivity.
- g-value.
- Glass manifestation.
- Solar heat gain coefficient.
- Thermal bridge.
- Thermal optical properties.
- Triple glazing.
- U value.
Featured articles and news
Change of use legislation breaths new life into buildings
A run down on Class MA of the General Permitted Development Order.
Solar generation in the historic environment
Success requires understanding each site in detail.
Level 6 Design, Construction and Management BSc
CIOB launches first-ever degree programme to develop the next generation of construction leaders.
Open for business as of April, with its 2026 prospectus and new pipeline of housing schemes.
The operational value of workforce health
Keeping projects moving. Incorporating unplanned absence and the importance of health, in operations.
A carbon case for indigenous slate
UK slate can offer clear embodied carbon advantages.
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.
The new towns and strategic environmental assessments
12 locations of the New Towns Taskforce reduced to 7 within the new towns draft programme and open consultation.
Buildings that changed the future of architecture. Book review.