Approved Document A
The first set of national building standards was introduced in 1965. Now known as the building regulations, they set out:
- What qualifies as 'building work' and so fall under the control of the regulations.
- What types of buildings are exempt.
- The notification procedures that must be followed when starting, carrying out, and completing building work.
- Requirements for specific aspects of building design and construction.
The 'approved documents' provide guidance for how the building regulations can be satisfied in common building situations. There is no obligation to adopt the solutions presented in the approved documents, the building regulations can be satisfied in other ways.
Approved Document A: Structure, was last published in 2013.
It requires buildings to be designed, constructed or altered so as to be structurally safe and robust, and so as not to impair the structural stability of other buildings. It deals with the requirements that buildings should be able to withstand dead loads, imposed loads and wind loads, as well as ground movement such as swelling, shrinkage or freezing of the subsoil, or land-slip or subsidence.
It stipulates the design standards for use on all buildings and gives simple design rules for most masonry and timber elements for traditional domestic buildings. It includes diagrams of structures such as roof frames and brick walls, and tables of material strengths.
The content of the Approved Document includes:
- Section 1: Codes, standards and references for all building types.
- Section 2: Sizes of structural elements for certain residential buildings and other small buildings of traditional construction – This includes basic requirements for stability, sizes of certain timber members, thickness of walls in certain small buildings, proportions for masonry chimneys above the roof structure, and foundations of plain concrete.
- Section 3: Wall cladding – This includes guidance on technical approach, loading and fixings.
- Section 4: Roof covering – This includes guidance on materials and re-covering of roofs.
- Section 5: Reducing the sensitivity of the building to disproportionate collapse in the event of an accident – This includes an alternative approach and seismic design.
- Standards referred to.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Change of use legislation breaths new life into buildings
A run down on Class MA of the General Permitted Development Order.
Solar generation in the historic environment
Success requires understanding each site in detail.
Level 6 Design, Construction and Management BSc
CIOB launches first-ever degree programme to develop the next generation of construction leaders.
Open for business as of April, with its 2026 prospectus and new pipeline of housing schemes.
The operational value of workforce health
Keeping projects moving. Incorporating unplanned absence and the importance of health, in operations.
A carbon case for indigenous slate
UK slate can offer clear embodied carbon advantages.
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.
The new towns and strategic environmental assessments
12 locations of the New Towns Taskforce reduced to 7 within the new towns draft programme and open consultation.
Buildings that changed the future of architecture. Book review.



















Comments