Limit state design
Contents |
[edit] What is limit state design
Loading or other actions imposed on a structure can result in a ‘limit state’, where the structure’s condition no longer fulfils its design criteria, such as; fitness for use, structural integrity, durability, and so on. Limit states are conditions of potential failure.
Limit state design (LSD) is a structural engineering design method. All actions likely to occur during a structure’s design life are considered to ensure that the structure remains fit for use with appropriate levels of reliability. Limit state design involves estimating the subjected loads on a structure, choosing the sizes of members to check, and selecting the appropriate design criteria.
Limit state design requires that two principal criteria are satisfied:
- Ultimate limit state (ULS).
- Serviceability limit state (SLS).
[edit] Ultimate limit state (ULS)
Ultimate limit state (ULS) is design for the safety of a structure and its users by limiting the stress that materials experience.
The ultimate limit state is a purely elastic condition, usually located at the upper part of its elastic zone (approximately 15% lower than the elastic limit). This is in contrast to the ultimate state (US) which involves excessive deformations approaching structural collapse, and is located deeply within the plastic zone.
If all factored bending, shear and tensile or compressive stresses are below the calculated resistances then a structure will satisfy the ULS criterion. Safety and reliability can be assumed as long as this criterion is fulfilled, since the structure will behave in the same way under repetitive loadings.
BS EN 1990 Eurocode – 'Basis of structural design' describes four ultimate limit states:
- EQU: Loss of static equilibrium of the structure.
- STR: Internal failure or excessive deformation of the structure.
- GEO: Failure or excessive deformation of the ground.
- FAT: Fatigue failure of the structure.
[edit] Serviceability limit state (SLS)
Servicability limit state (SLS) is design to ensure a structure is comfortable and useable. This includes vibrations and deflections (movements), as well as cracking and durability. These are the conditions that are not strength-based but still may render the structure unsuitable for its intended use, for example, it may cause occupant discomfort under routine conditions. It might also involve limits to non-structural issues such as acoustics and heat transmission.
Servicability limit state requirements tend to be less rigid than strength-based limit states as the safety of the structure is not in question.
A structure must remain functional for its intended use subject to routine loading in order to satisfy SLS criterion.
[edit] Related articles on Designing Buildings
- Adaptive structures.
- Anticlastic structures.
- Biaxial bending.
- Braced frame.
- Building science.
- Concept structural design of buildings.
- Defects in construction.
- Lateral loads.
- Material utilisation (MUT).
- Shear force.
- Structural engineer.
- Structural steelwork.
- Structural vibration.
- Synclastic.
- Types of structural load.
[edit] External resources
- BGStructural Engineering - LSD
- Handbook of structural steelwork, Eurocode Edition, 2013.
Featured articles and news
A UK training and membership provider for mould remediation professionals.
Building Safety recap April, 2026
A short and longer run-through of the month, with links to further information and sources.
CIAT May 2026 briefing.
Independent NSI and BAFE study exploring how organisations are changing the way they buy fire safety services.
From medieval scribes to modern word art.
ECA welcomes crackdown on late payment and push for clean energy, whilst CIOB seek fixed cladding removal timeframes.
Cyber Security in the Built Environment
Protecting projects, data, and digital assets: A CIOB Academy TIS.
Managing competence in the built environment
ITFG publishes new industry guide on how to meet the ICC principles.
The UK's campaign to reduce noise pollution: Mythbusting, articles and topic guides.
Setting Expectations on Competence Management
Industry Competence Committee.
New Scottish and Welsh governments
CIOB stresses importance of construction after new parliament elections.
The sad story of Derby Hippodrome
An historic building left to decay.
ECA, JIB and JTL back Fabian Society call to invest in skills for a stronger built environment workforce.
Women's Contributions to the Built Environment.
Calls for the delayed Circular Economy Strategy
Over 50 leading businesses, trade associations and professional bodies, including CIAT, and UKGBC sign open letter.
The future workforce: culture change and skill
Under the spotlight at UK Construction Week London.
A landmark moment for postmodern heritage.
























Comments
[edit] To make a comment about this article, click 'Add a comment' above. Separate your comments from any existing comments by inserting a horizontal line.