Vibrations in buildings
Vibrations are the oscillatory motions that can be experienced by a building, usually through its floors. Vibrations are regular cyclic motions of a given frequency and amplitude, typically being vertical vibrations, although horizontal vibrations are possible.
The length of a wave vibration is measured from the beginning of one point on a wave to the same point on the next wave and is known as the frequency. This is expressed as Hertz (Hz). The height of a wave vibration is measured from the centre line and is known as the amplitude. This is expressed in metres. The larger the amplitude, the slower the wave is as it moves from peak to trough (oscillation).
The consequences of building vibrations are determined by the source of the motion, its duration, and the building’s construction and layout. They may include:
- Presenting a nuisance to occupants.
- Disturbing sensitive equipment.
- Causing fixture and fittings damage
- Damaging structural integrity.
- The consequences will be .
Vibrations that affect buildings can be produced by a variety of sources and most are felt through the floor system. Vibrations can originate directly in the floor and then travel out from the source, or can be propagated through building members from other sorces that originate in the ground or outside the building.
Internal sources include:
- HVAC equipment.
- Lift and conveyance systems.
- Fluid pumping equipment.
- Human activity, e.g. walking, dancing, aerobic exercises, etc.
External sources include:
- Seismic activity.
- Road, rail, subway systems.
- Industrial activities.
- Construction activities, e.g. demolition works.
- Wind buffeting.
As even very low amplitudes of vibration can be perceived by occupants, building designers must consider how to avoid nuisance being caused through vibration. They should also consider the structural strength to ensure it is enough to resist the peak dynamic forces acting on it. Structural members and their connections must be designed to resist such forces, and connections must be designed to ensure that fatigue does not occur due to repeated cyclic loading.
Frequency and amplitude are taken into building designers’ calculations to determine where extra stiffness is required to dampen the vibration. Damping refers to the minimising of amplitude in a vibration or mechanical energy loss.
Anticipated usage of the floors is a critical consideration that should inform the concept design. Similarly, if a building is being constructed near a busy road or above a subway system, the foundations should be carefully detailed to accommodate the likely vibrations.
During the initial design of a building, the likelihood of perceptible vibration in sensitive spaces should be carefully assessed. This is particularly important for buildings that are designed with an unusual geometry or complicated structural systems. As the complexity of a structure increases, the impact of vibration becomes more difficult to accurately predict and effectively minimise.
It is important that building designers properly consider levels of acceptable vibration at the concept design stage as it can be very difficult, and costly, to modify an existing floor to reduce its susceptibility to vibration. Remediation may require major changes to the mass, stiffness or damping of the floor system.
Vibrations are sometimes dealt with most effectively at source. For instance, machinery-induced vibrations can be minimised by using isolating mounts or motion-arresting pads. An inexpensive approach is to increase the floor loading within the building. Weight can be placed under a raised floor to minimise movement from foot traffic for instance, and dissipate vibration.
NB A vibration dose value is defined in BS6472-1(2008) as a relationship that yields a consistent assessment of vibration which correlates well with subjective response. It is used to estimate the probability of adverse comment which might be expected from human beings experiencing vibration in buildings. Consideration is given to the time of day and use made of occupied space in buildings, whether residential, office or workshop.
[edit] Related articles on Designing Buildings
Featured articles and news
Do you take the lead in a circular construction economy?
Help us develop and expand this wiki as a resource for academia and industry alike.
Warm Homes Plan Workforce Taskforce
Risks of undermining UK’s energy transition due to lack of electrotechnical industry representation, says ECA.
Cost Optimal Domestic Electrification CODE
Modelling retrofits only on costs that directly impact the consumer: upfront cost of equipment, energy costs and maintenance costs.
The Warm Homes Plan details released
What's new and what is not, with industry reactions.
Could AI and VR cause an increase the value of heritage?
The Orange book: 2026 Amendment 4 to BS 7671:2018
ECA welcomes IET and BSI content sign off.
How neural technologies could transform the design future
Enhancing legacy parametric engines, offering novel ways to explore solutions and generate geometry.
Key AI related terms to be aware of
With explanations from the UK government and other bodies.
From QS to further education teacher
Applying real world skills with the next generation.
A guide on how children can use LEGO to mirror real engineering processes.
Data infrastructure for next-generation materials science
Research Data Express to automate data processing and create AI-ready datasets for materials research.
Wired for the Future with ECA; powering skills and progress
ECA South Wales Business Day 2025, a day to remember.
AI for the conservation professional
A level of sophistication previously reserved for science fiction.
Biomass harvested in cycles of less than ten years.
An interview with the new CIAT President
Usman Yaqub BSc (Hons) PCIAT MFPWS.
Cost benefit model report of building safety regime in Wales
Proposed policy option costs for design and construction stage of the new building safety regime in Wales.
Do you receive our free biweekly newsletter?
If not you can sign up to receive it in your mailbox here.























Comments
[edit] To make a comment about this article, click 'Add a comment' above. Separate your comments from any existing comments by inserting a horizontal line.