Separating floor
The term ‘separating floor’ is generally used to describe a floor designed to restrict the passage of sound between the spaces above and below. It is most commonly used in relation to residential buildings. In this context, a ‘separating wall’ is one that separates adjoining residential rooms or properties.
Construction clients may have particular acoustic requirements that should be recorded in the project brief, however, the legal requirement for building construction to resist the passage of sound is set out in part E of the building regulations, which describes requirements for:
- Dwelling-houses, flats and rooms for residential purposes.
- The common internal parts of buildings containing flats or rooms for residential purposes which give access to the flat or room.
- Schools.
The requirements of part E of the building regulations can be satisfied by following the guidance in Approved Document E: Resistance to the passage of sound.
Whilst not exhaustive, approved document E describes types of separating floor as:
- Floor type 1: Concrete base with ceiling and soft floor covering.
- Floor type 2: Concrete base with ceiling and floating floor.
- Floor type 2: Floating floor.
- Floor type 3: Timber frame base with ceiling and platform floor.
Three ceiling types are also described:
- A: Independent ceiling with absorbent material.
- B: Plasterboard on proprietary resilient bars with absorbent material.
- C: Plasterboard on timber battens or proprietary resilient channels with absorbent material.
Critical to the success of each construction, is the detailing of junctions between the floor and other elements such as walls and floor penetrations. Common junction details are illustrated in the approved document, as are performance standards and pre-completion testing requirements.
For more information see Approved Document E.
NB walls and floors may also be elements of a building that are required to provide fire separation.
Approved document E: Resistance to the passage of sound, 2003 edition incorporating 2004, 2010, 2013 and 2015 amendments, defines an Internal floor as: ‘Any floor that is not a separating floor.’ Where a separating floor is a: ‘Floor that separates flats or rooms for residential purposes.’
[edit] Related articles on Designing Buildings
Featured articles and news
Editor's broadbrush view on forms of electrical heating in context.
The pace of heating change; BSRIA market intelligence
Electric Dreams, Boiler Realities.
New President of ECA announced
Ruth Devine MBE becomes the 112th President of the Electrical Contractors Association.
New CIAT Professional Standards Competency Framework
Supercedes the 2019 Professional Standards Framework from 1 May 2025.
Difficult Sites: Architecture Against the Odds
Free exhibition at the RIBA Architecture Gallery until 31 May.
PPN 021: Payment Spot Checks in Public Sub-Contracts
Published following consultation and influence from ECA.
Designing Buildings reaches 20,000 articles
We take a look back at some of the stranger contributions.
Lessons learned from other industries.
The Buildings of the Malting Industry. Book review.
Conserving places with climate resilience in mind.
Combating burnout.
The 5 elements of seiri, seiton, seiso, seiketsu and shitsuke.
Shading for housing, a design guide
A look back at embedding a new culture of shading.
The Architectural Technology Awards
The AT Awards 2025 are open for entries!
ECA Blueprint for Electrification
The 'mosaic of interconnected challenges' and how to deliver the UK’s Transition to Clean Power.
Grenfell Tower Principal Contractor Award notice
Tower repair and maintenance contractor announced as demolition contractor.