Minimum efficiency reporting value MERV
Contents |
[edit] Introduction
The minimum efficiency reporting value (MERV) can be used to evaluate the effectiveness of air filters in heating, ventilation and air conditioning (HVAC) components.
[edit] Background
The rating system was developed in the 1980s by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). ASHRAE develops standards related to refrigeration processes and the design and maintenance of indoor environments. The purpose of the organisation's standards is to establish consensus for test use in commerce as well as performance criteria for use as facilitators.
This MERV rating system is used in the US for comparing air filters made by different manufacturers. It assigns a single number air filter designation based on how well it captures and holds dust. MERV rated filters may be used in place of high efficiency particulate arrestance (HEPA) or ultra low particulate air (ULPA) filters in certain circumstances (such as when central air conditioning systems are in place).
[edit] MERV testing
The MERV rating system is based on ASHRAE Standard 52.2-2007, the testing protocol for air filtration performance.
It reflects a measurement of the filter’s arrestance - or its ability to remove dust from the air - relative to how many of a specific size dust particle (within the range of 0.3 to 10 micrometers) need to be removed to keep HVAC equipment clean.
The test extends over six cycles and begins with a clean filter. During each cycle, a measured amount of particles (broken down into three size categories) is released into the test airstream. These three arrestances are:
- E1 for small particles such as tobacco smoke and bacteria.
- E2 for medium size particles such as welding fumes.
- E3 for larger particles such as dirt, lint, hair and dust.
The number of particles trapped and missed is measured. This procedure is repeated five additional times and the MERV rating is calculated based on the poorest performance rating during the six tests.
The MERV number corresponds to the filter’s efficiency in its clean, least efficient state (which is why the rating is referred to as ‘minimum efficiency’). A filter increases in efficiency as it loads.
[edit] Explanation of ratings
MERV values range from 1 (minimal filtering) to 16 (maximum filtering).
Mid-range rated filters (from 7 to 13) are typically recommended for commercial buildings. During the new construction phase, MERV 8 filters may be advisable, with MERV 13 filters generally recommended once the building is operational.
(NB: MERV 17-20 ratings are no longer acknowledged by ASHRAE.) |
Sample rating ranges include:
- MERV 1 to 4. These filters are made from materials such as fibreglass and aluminium mesh. They can be used to remove large particles and protect equipment. They can remove substances such as pollen, dust mites, cockroach debris and carpet fibres and are suitable for light industrial and some residential applications including residential window air conditioning units.
- MERV 5 to 8. These are disposable filters that can be used to remove substances such as mould spores, pet dander and other particulate material commonly found in residential environments and some light industrial and commercial environments.
- MERV 9 to 12. These are higher quality filters used to remove fine household dust particles (such as flour), and Legionella as well as some particles found in workshop fumes. These can be used in more demanding residential, commercial and healthcare environments.
- MERV 13 to 16. These are designed for high levels of filtration for substances such as bacteria, smoke dust and other extremely fine particles. They are suitable for commercial and healthcare applications with extreme filtration requirements. These filters are not suitable for residential HVAC applications or furnaces.
Originally, MERV values ranged from 1 to 20, but ASHRAE stopped recognising MERV values from 17 to 20 in January 2009. This range is instead represented by HEPA and ULPA filters, which are capable of removing extremely high levels of dust particles as well as some viruses and other dangerous airborne particulates.
[edit] The impact of air resistance on MERV
In a furnace or air handler, the queuing up of air to pass through a high-MERV filter creates resistance. Referred to in HVAC language as a pressure drop, this condition decreases airflow on the downstream side of the air filter.
Pressure drop may increase as the MERV number increases. As contaminants load on the filter, pressure in the system rises and can have a negative impact on airflow. This may cause systems to operate for longer periods of time in order to reach certain temperature settings. In extreme cases, decreased airflow over the part of the system that heats (in winter) or cools (in summer) can lead to overheating and an automated system shutdown or icing over of the coil.
[edit] Related articles on Designing Buildings
- Air filtration.
- Air pressure drop APD.
- Arrestance.
- At a glance - Indoor air quality.
- Building ventilation and COVID-19 transmission risk.
- Clean air delivery rate CADR
- Clean indoor air for healthy living - New air filter standards.
- Designing HVAC to resist harmful microorganisms.
- Growing focus on IAQ challenges for specifiers and HVAC manufacturers.
- High efficiency particulate arrestance HEPA.
- HVAC.
- Indoor air quality.
- Mechanical ventilation of buildings.
Featured articles and news
Conservation and transformation
Reading Ruskin’s cultural heritage. Book review.
Renovating Union Chain Bridge.
AI tools for planning, design, construction and management
A long, continually expanding list, any more to add?
Robots in the construction industry
From cultural characterisations to construction sites.
Empowering construction with AI integration
New horizons with a human touch.
Key AI related terms to be aware of
With explanations from the UK government.
A Better Hiring Toolkit for construction
Tooling up to hire under best practice standards in the sector.
Recharging Electrical Skills in Wales
Step by step collaborative solutions.
Ireland budget announcement 2025
CIOB responds with positivity, criticism and clarity.
The continued ISG fall out, where to go?
Support for ISG contractors, companies and employees.
New HES national centre for traditional building retrofit
Announced as HES publishes survey results which reveal strong support for retrofit.
Retrofit of Buildings, a CIOB Technical Publication
Expected to become one of the largest activities in the global construction industry.
Scope determination appeals and the Building Safety Act
Process explained following release of appeals guidance.
The ECA industry focus video channel
Keeping update with the industry session by session.
Over 25 recorded informations sessions freely available.
AT Awards 2024 ceremony East London October 25th.
Revisiting the AT community at the 2023 awards evening.