Habitable room
Approved document F, Ventilation, suggests that a ‘habitable room’ is:
‘…a room used for dwelling purposes but which is not solely a kitchen, utility room, bathroom, cellar or sanitary accommodation.’
Whereas an ‘occupiable room’ is:
‘…a room in a building other than a dwelling that is occupied by people, such as an office, workroom, classroom or hotel bedroom, but not a bathroom, sanitary accommodation, utility room or rooms or spaces used solely or principally for circulation, building services plant or storage purposes.
Other definitions include:
- Approved document B, Fire Safety, Volume 2, Buildings other than dwellinghouses (2019 edition), defines a habitable room as: 'A room used, or intended to be used, for people to live in (including, for the purposes of Approved Document B Volumes 1 and 2, a kitchen, but not a bathroom).'
- Approved document M1, Access to and use of buildings: dwellings, defines a habitable room as: 'A room used, or intended to be used, for dwelling purposes, including a kitchen but not a bathroom or utility room.'
- The English Housing Survey Housing Stock Report, 2014-15, prepared by the Department of Communities and Local Government, defines a habitable room as: 'A room in the dwelling that offers ‘living accommodation’. Includes bedrooms, kitchens if there is additional space to provide a dining area large enough to accommodate a table and chairs (typically an area of 2m² in addition to kitchen space). A fully converted room in the loft space is classified as a habitable room even if it can only be reached by a fixed ladder or unsafe staircase.' This definition is repeated in The English Housing Survey, Profile and condition of the English housing stock, 2018-19, Published by the Ministry of Housing, Communities & Local Government in August 2020.
- The Scottish Building Standards refer to a 'principal habitable room' in relation to the provision of fire detection and fire alarm systems. They define a principal habitable room as ‘…a frequently used room by the occupants of a dwelling for general daytime living purposes.’
- The Home Quality Mark defines a habitable room as ‘…a room used for home purposes, but which is not solely a kitchen, utility room, bathroom, cellar or sanitary accommodation.’ Ref Home Quality Mark One, Technical Manual SD239, England, Scotland & Wales, published by BRE in 2018. http://www.homequalitymark.com/standard
- BREEAM UK New Construction, Non-domestic Buildings (United Kingdom), Technical Manual, SD5078: BREEAM UK New Construction 2018 3.0, published by BRE Global Limited suggest that in relation to acoustic performance; '...habitable rooms include any room where individuals will sit or lie down and require a reasonably quiet environment in which to concentrate or rest. Such rooms are bedrooms, living rooms, dining rooms, studies as well as kitchen-dining and kitchen-living rooms.'
- Land measurement for planning and development purposes, Guidance Note, Global 1st edition, Published by the Royal Institution of Chartered Surveyors (RICS) in May 2021, states: ‘Different jurisdictions may define habitable rooms differently. Typically, habitable rooms provide the living accommodation of the dwelling. They include living room, dining room, study, home office, conservatory and bedrooms. They exclude the bathroom, WC, utility room, storeroom, circulation space and kitchen (unless it provides space for dining).’
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.
Plumbing and heating for sustainability in new properties
Technical Engineer runs through changes in regulations, innovations in materials, and product systems.
Awareness of the Carbon Border Adjustment Mechanism
What CBAM is and what to do about it.
The new towns and strategic environmental assessments
12 locations of the New Towns Taskforce reduced to 7 within the new towns draft programme and open consultation.
Buildings that changed the future of architecture. Book review.
The Sustainability Pathfinder© Handbook
Built environment agency launches free Pathfinder© tool to help businesses progress sustainability strategies.
Government outcome to the late payment consultation, ECA reacts.
IHBC 2025 Gus Astley Student Award winners
Work on the role of hewing in UK historic conservation a win for Jack Parker of Oxford Brookes University.
Future Homes Building Standards and plug-in solar
Parts F and L amendments, the availability of solar panels and industry responses.
How later living housing can help solve the housing crisis
Unlocking homes, unlocking lives.
Preparing safety case reports for HRBs under the BSA
A new practical guide to preparing structural inputs for safety cases and safety case reports published by IStructE.
Male construction workers and prostate cancer
CIOB and Prostate Cancer UK encourage awareness of prostate cancer risks, and what to do about it.