[edit] Introduction
Fire separation is the method for protecting buildings from the spread of fire into adjoining areas for designated time periods by the introduction of fire resisting walls, floors, doors, ducts and so on. These time periods are set out in the Building Regulations. These constructions divide the building into distinct fire zones called ‘fire compartments’. In such cases, the walls and floors are referred to as compartment walls and compartment floors.
In general, when any of those elements is prefixed by the word compartment, it designates that it has been designed and constructed to have a specific period of fire resistance, typically for 30, 60, 90 or 120 minutes. The level of performance will depend on the type of building in question and the requirements of Approved Document B of the Building regulations (England and Wales) or Part E (Scotland and Northern Ireland).
The period of time during which the element acts as a barrier to the spread of fire is intended to prevent it from developing into a much larger fire, to give people in adjoining accommodation sufficient time to escape, and to limit the damage caused.
In cases where a fire separating element includes an opening, such as a door, internal window, penetrating duct or access panel, it must have the same fire rating as the element in question in order to maintain the fire separation qualities of the construction.
When a duct penetrates a compartment wall or floor, it must be ‘fire stopped’ (ie material is packed around the duct to create a seal and so achieve the same fire resistance as the wall or floor and ensure the opening does not form a route for fire spread). Fore more information see: Fire stopping.
Fire dampers are installed in the ducts of heating, ventilation and air conditioning systems which penetrate fire-resistant constructions and will automatically close on the detection of heat.
In a simple four-storey office building, with each floor comprising two escape stairs and an open plan office area with no internal partitions, the escape stairs will be enclosed by fire walls and fire doors. This makes each staircase a multi-storey fire compartment which will be designed to ensure that any outbreak of fire in the office areas cannot penetrate into the protected stair for the designated fire period.
An office building of greater complexity, eg with separate meeting rooms, canteen areas etc, may have a more complex fire compartmentation requirement and more fire compartments. Other considerations that will affect the degree of sub-division are the height of the building, its fire load and the availability of a sprinkler system.
For more information see: Fire compartmentation.
Fire separation and the creation of compartments has generally proved to be a successful system of containing fires in buildings and so reducing loss of life. However, problems may arise during periods of maintenance or refurbishment when old elements are replaced, and/or new constructions introduced that compromise or do not meet the original fire safety levels.
[edit] Related articles on Designing Buildings Wiki
- Compartment floor.
- Compartment wall.
- Escape route.
- Fire.
- Fire and rescue service.
- Fire detection and alarm systems.
- Fire resistance.
- Fire risk assessments and historic buildings.
- Fire safety design.
- Fire-separating element.
- Fire spread.
- Fire-stopping.
- Grenfell Tower.
- Means of escape.
- Protected escape route.
- Protected stairway.
- Unprotected escape route.
Featured articles and news
The UK’s largest air pollution campaign.
Future Homes Standard, now includes solar, but what else?
Will the new standard, due to in the Autumn, go far enough in terms of performance ?
BSRIA Briefing: Cleaner Air, Better tomorrow
A look back at issues relating to inside and outside air quality, discussed during the BSRIA briefing in 2023.
Restoring Abbotsford's hothouse
Bringing the writer Walter Scott's garden to life.
Reflections on the spending review with CIAT.
Retired firefighter cycles world to raise Grenfell funds
Leaving on 14 June 2025 Stephen will raise money for youth and schools through the Grenfell Foundation.
Key points for construction at a glance with industry reactions.
Functionality, visibility and sustainability
The simpler approach to specification.
Architects, architecture, buildings, and inspiration in film
The close ties between makers and the movies, with our long list of suggested viewing.
SELECT three-point plan for action issued to MSPs
Call for Scottish regulation, green skills and recognition of electrotechnical industry as part of a manifesto for Scottish Parliamentary elections.
UCEM becomes the University of the Built Environment
Major milestone in its 106-year history, follows recent merger with London School of Architecture (LSE).
Professional practical experience for Architects in training
The long process to transform the nature of education and professional practical experience in the Architecture profession following recent reports.
A people-first approach to retrofit
Moving away from the destructive paradigm of fabric-first.
International Electrician Day, 10 June 2025
Celebrating the role of electrical engineers from André-Marie Amperè, today and for the future.
New guide for clients launched at Houses of Parliament
'There has never been a more important time for clients to step up and ...ask the right questions'
The impact of recycled slate tiles
Innovation across the decades.
EPC changes for existing buildings
Changes and their context as the new RdSAP methodology comes into use from 15 June.