Dry seals for metal composite material systems
Dry seal systems are one of the original MCM installation systems, along with wet seals, with more component parts they have been used for around 40 years in the US and still widely used today. Also known as a “single line barrier wall” or “fully-sealed wall”, wet seal systems are installed with a joint located between adjacent panels that is fully sealed with exposed sealant. Tested in the US to AAMA 501 & 501.1 standards, in the UK fire class tests will likely be according to Euroclass A1 or A2, A or B as the lower rating.
The Centre for Window and Cladding Technology (CWCT) defines a rainscreen cladding system as '...a wall comprising an outer skin of panels and an airtight insulated backing wall separated by a ventilated cavity. Some water may penetrate into the cavity but the rainscreen is intended to provide protection from direct rain'.
The Metal Constuction Association, Technical Bulletin MCM Panel System Definitions, dated March 2018 describes the design and functions of MCM Wet Seal Systems as thus:
"A Dry Seal system is defined as a panel system where the joints between panels provide weather resistance without relying on the application of exposed or concealed sealants within the joints. In one typical method of achieving a Dry Seal system, the perimeter of the MCM panel is affixed with gasketed interlocking perimeter extrusions or formed metal profiles. These extrusions nest together in a gasketed pocket as shown in Figure 2. It should be noted that not all extrusions creating a Dry Seal system utilize gaskets, yet they perform very adequately as an exterior cladding."
"Water infiltration is primarily controlled by the interlocking extrusions. Any water or condensation that may find its way into the panel cavity is controlled and directed to the exterior through weep holes keeping the interior cavity dry. The Dry Seal system should perform the same with or without an air/water barrier. To properly test a Dry Seal system, the mockup is constructed without any barrier in place and the backside of the panels are exposed directly to the interior chamber pressures. Testing in this fashion shows the effectiveness of the system, designed to perform even if the air/water barrier is compromised."
[edit] Related articles on Designing Buildings
- Building fabric.
- Cladding.
- Composites.
- Copper.
- Crinkly tin.
- Curtain wall systems.
- Drained and back ventilated rainscreen systems.
- Glazing.
- Metal.
- Metal composite material panel systems MCM and MCP.
- Metal profile cladding.
- Metal roofing.
- Modernising composite materials regulations.
- Pressure equalized rainscreen systems.
- Rainscreen.
- Sandwich panel.
- Shingle roofing.
- Wall types.
- Weatherboarding.
- Wet Seals for metal composite material systems.
- Zinc
Featured articles and news
Edmundson Apprentice of the Year award 2026
Entries now open for this Electrical Contractors' Association award.
Traditional blue-grey slate from one of the oldest and largest UK slate quarries down in Cornwall.
There are plenty of sources with the potential to be redeveloped.
Change of use legislation breaths new life into buildings
A run down on Class MA of the General Permitted Development Order.
Solar generation in the historic environment
Success requires understanding each site in detail.
Level 6 Design, Construction and Management BSc
CIOB launches first-ever degree programme to develop the next generation of construction leaders.
Open for business as of April, with its 2026 prospectus and new pipeline of housing schemes.
The operational value of workforce health
Keeping projects moving. Incorporating unplanned absence and the importance of health, in operations.
A carbon case for indigenous slate
UK slate can offer clear embodied carbon advantages.
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.