Pile foundations are deep foundations. They are formed by long, slender, columnar elements typically made from steel or reinforced concrete, or sometimes timber. A foundation is described as 'piled' when its depth is more than three times its breadth.
The bearing capacity of a pile is determined by several factors, including the size, shape and type of pile, as well as the particular soil properties. The calculation method that is used as a means of testing pile foundations depends upon the magnitude of the work involved, the soil type, and the engineer’s specification. Methods of calculation include:
- Dynamic pile formulae.
- Static formula.
- Test loading.
The integrity of, and presence of defects in, new and existing piles can be assessed by carrying out a pile integrity test.
[edit] Dynamic formulae
In mainly non-cohesive soils, dynamic formulae can be used to calculate the approximate bearing capacity of piles. These are based on assumptions, including:
- The resistance to being driven into the soil is determined from the energy delivered by the hammer together with the pile movement when struck by the hammer.
- Resistance to being driven into the soil is equal to the ultimate bearing capacity for static loads.
The basis of the formulae is that the ability to overcome the ground resistance to penetration is equated with the energy delivered by the hammer on impact. A factor of safety must be applied when the ultimate bearing capacity has been achieved, before calculating the safe working load. This can vary according to the pile’s permitted settlement rate at working load, which is determined by the pile size and the soil compressibility.
[edit] Static formulae
For non-cohesive soils, the static formulae that can be used to test piles include the standard penetration test and the cone penetration test.
The standard penetration test involves measuring the soil’s resistance to penetration under static or dynamic loading. For more information, see Standard penetration test.
The cone penetration test involves a cone enclosed in a tube. This is pushed into the soil, and measurements are taken of the forces that are required to independently advance the cone and tube. The resistance of the cone to being driven into the soil is taken as being equal to the ultimate bearing capacity.
Laboratory tests are more suitable for estimating the shear strength values of cohesive soils.
[edit] Test loading
It is advisable to test load at least one pile per scheme by forming a trial pile that is in close proximity but does not form part of the actual foundations. The pile should be overloaded by at least 50% of its working load and held for 24 hours. This provides a check on the ultimate bearing capacity of the pile as well as the workmanship involved in forming the pile.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.
The place for vitrified clay pipes in modern infrastructure
Why vitrified clay pipes are reclaiming their role in built projects.
Research by construction PR consultancy LMC published.
Roles and responsibilities of domestic clients
ACA Safety in Construction guide for domestic clients.
Fire door compliance in UK commercial buildings
Architect and manufacturer gives their low down.
Plumbing and heating for sustainability in new properties
Technical Engineer runs through changes in regulations, innovations in materials, and product systems.
Awareness of the Carbon Border Adjustment Mechanism
What CBAM is and what to do about it.
The new towns and strategic environmental assessments
12 locations of the New Towns Taskforce reduced to 7 within the new towns draft programme and open consultation.
Buildings that changed the future of architecture. Book review.
The Sustainability Pathfinder© Handbook
Built environment agency launches free Pathfinder© tool to help businesses progress sustainability strategies.
Government outcome to the late payment consultation, ECA reacts.
IHBC 2025 Gus Astley Student Award winners
Work on the role of hewing in UK historic conservation a win for Jack Parker of Oxford Brookes University.
Future Homes Building Standards and plug-in solar
Parts F and L amendments, the availability of solar panels and industry responses.
How later living housing can help solve the housing crisis
Unlocking homes, unlocking lives.
Preparing safety case reports for HRBs under the BSA
A new practical guide to preparing structural inputs for safety cases and safety case reports published by IStructE.
Male construction workers and prostate cancer
CIOB and Prostate Cancer UK encourage awareness of prostate cancer risks, and what to do about it.