The design life (or design service life) of a building, other structure or component, is the period of use as intended by the designer after which it may need to be replaced. Before this period has elapsed, it should remain fit for purpose.
Design life will vary according to the type and use of the element being considered. BS EN 1990, Eurocode - Basis of structural design, (Eurocode 0) gives indicative design lives for various types of structure:
- Category 1: Temporary structures, not including structures or parts of structures that can be dismantled with a view to being re-used – 10 years.
- Category 2: Replaceable structural parts, e.g. gantry girders, bearings – 10 to 25 years.
- Category 3: Agricultural and similar buildings – 15 to 30 years.
- Category 4: Building structures and other common structures – 50 years.
- Category 5: Monumental building structures, bridges and other civil engineering structures – 100 years.
The design life of some components may be affected by environmental factors such as:
- Moisture, humidity and rain.
- Wind.
- Temperature and temperature fluctuations.
- Pollution.
- Solar radiation.
It may also be affected by considerations such as maintenance practices, intensity of use, and so on.
There is no legally agreed definition of design life (in fact, there is not even a legally agreed definition of 'design'), so if it is to be included in contract documentation as a performance requirement, it is important that it is carefully defined within the contract documents and that it is consistent with all other requirements in the contract documents.
Several other definitions have been developed to quantify the life of buildings, structures and their components, including:
[edit] Related articles on Designing Buildings
- Cradle-to-grave.
- Decommissioning.
- Demolition.
- Economic life.
- End of life potential.
- Fitness for purpose.
- Functional life.
- Life.
- Life cycle.
- Life cycle assessment.
- Obsolescence.
- Permanent structure.
- Re-evaluating the design life of buildings.
- Required life.
- Service life.
- Structures at the end of their design life.
- Technical life.
- Temporary structure.
- Useful life.
- Utilising life cycle costing and life cycle assessment.
- Whole-life costs.
- Whole-life value.
Featured articles and news
Net zero electricity grids BSRIA guide NZG 5/2024
Outlining the changes needed to transition to net zero.
CIOB Global Student Challenge 2024
Universitas Indonesia wins for second year running.
New project and cultural district described in detail.
The nature of EPCs, crticism and inaccuracies.
History, issues and redesign.
From waste recycling to energy performance the hierchy.
An introduction to WERCS and WEEE responsibilities
Dealing 2 million tonnes of waste equipment a year.
Global BACS Market: analytics and optimisation
A BSRIA glance at building automation and control systems.
What it is and how to use it.
Types of insulating plaster by binder and insulant.
Investors in People: CIOB achieves gold
Reflecting a commitment to employees and members.
Scratching beneath the surface; a guide to selection.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
UK gov apprenticeship funding from April 2024
Brief summary the policy paper updated in March.
For the World Autism Awareness Month of April.
Comments