[edit] Aim and benefits
The aim of this issue is to ensure the building is capable of creating an appropriate acoustic environment to provide comfort, occupant efficiency and privacy for building users.
Well-designed buildings minimise disturbances to building occupants from various sources including building systems, other occupants, equipment and external noise and provide appropriate acoustic environments for different functions and spaces.
Buildings are measured on whether they meet the appropriate acoustic performance standards and testing requirements defined for:
[edit] When to consider
BREEAM awards credits where a building meets the appropriate acoustic performance standards and testing requirements, specific to the building type (see below) or where a suitably qualified acoustician is appointed to define a bespoke set of performance requirements for all function areas in the building.
- Education.
- Healthcare.
- Offices.
- Law courts.
- Industrial, retail, prisons and other buildings.
- Residential institutions (short term and long term stay).
Early appointment of a suitably qualified acoustician (SQA) will allow performance and testing requirements to be designed into architectural construction and building services specifications.
[edit] Step-by-step guidance
To demonstrate compliance at the design stage, a suitably qualified acoustician should be appointed to provide a design report including noise survey results, appropriate noise limits, building construction and ventilation together with comments as to whether the design can meet these limits.
A programme of pre-completion testing to be carried out by a compliant test body is required. This programme should contain details of the required performance standards for relevant spaces.
The results of the post-completion testing are required for final certification.
Where testing identifies that spaces do not meet the standards, remedial works must be carried out prior to handover and occupation. Any failed areas will require re-testing if the credits are to be achieved.
[edit] Questions to ask while seeking compliance
Noise control predictions are based on the specified construction, with no allowance made for weak points. Small weaknesses in the fabric design and/or installation are likely to significantly reduce the predicted noise control performance. Comprehensive site construction checks (documented by the principal contractor or 3rd party) are required to prove that the installation matches the design intent.
Confirmation that all elements are constructed in accordance with the manufacturer’s recommendations are also required. All purchase contracts should include the particular elements to comply with the acoustic requirements.
[edit] Tools and resources
The primary professional body for acoustics in the UK is the Institute of Acoustics.
[edit] Tips and best practice
Façade noise levels – to determine the noise climate, the SQA should undertake a baseline noise survey at a location representative of the development exposed to the main noise sources affecting the site.
Ventilation – Where spaces are to be mechanically ventilated, the ventilation system will need to be suitable attenuated to ensure external noise is controlled. The SQA should check the details supplied by the M&E consultant to ensure that the cumulative noise limits are not exceeded. If this information is not available then the suitable internal noise limits should be provided for the mechanical plant based on the cumulative noise limits and the predicted internal noise level from external sources.
[edit] Typical evidence
- SQA’s (bespoke) report and evidence that requirements have been written into the specification.
- Final post-construction testing results. Where remediation is required, results of re-testing.
[edit] Applicable schemes
The guidelines collated in this ISD aim to support sustainable best practice in the topic described. This issue may apply in multiple BREEAM schemes covering different stages in the life of a building, different building types and different year versions. Some content may be generic but scheme nuances should also be taken into account. Refer to the comments below and related articles to this one to understand these nuances. See this document for further guidelines.
- BREEAM UK NC 2018
BRE Global does not endorse any of the content posted and use of the content will not guarantee the meeting of certification criteria.
[edit] Related articles on Designing Buildings Wiki
- Acoustic consultant.
- Acoustics.
- Airborne sound.
- Approved Document E.
- Audio frequency.
- BREEAM.
- Building Bulletin 93: acoustic design of schools.
- Decibel.
- Flanking sound.
- Impact sound.
- Noise nuisance.
- Pre-completion sound testing.
- Reverberation.
- Robust details certification scheme.
- Room acoustics.
- Sound absorption.
- Sound insulation.
- Sound insulation in dwellings: Part 1: An introduction (GG 83-1).
- Sound reduction index (SRI).
- Sound v noise.
- Structure-borne sound.
- Suitably Qualified Acoustician.
Featured articles and news
The 5 elements of seiri, seiton, seiso, seiketsu and shitsuke.
Shading for housing, a design guide
A look back at embedding a new culture of shading.
The Architectural Technology Awards
The AT Awards 2025 are open for entries!
ECA Blueprint for Electrification
The 'mosaic of interconnected challenges' and how to deliver the UK’s Transition to Clean Power.
Grenfell Tower Principal Contractor Award notice
Tower repair and maintenance contractor announced as demolition contractor.
Passivhaus social homes benefit from heat pump service
Sixteen new homes designed and built to achieve Passivhaus constructed in Dumfries & Galloway.
CABE Publishes Results of 2025 Building Control Survey
Concern over lack of understanding of how roles have changed since the introduction of the BSA 2022.
British Architectural Sculpture 1851-1951
A rich heritage of decorative and figurative sculpture. Book review.
A programme to tackle the lack of diversity.
Independent Building Control review panel
Five members of the newly established, Grenfell Tower Inquiry recommended, panel appointed.
Welsh Recharging Electrical Skills Charter progresses
ECA progressing on the ‘asks’ of the Recharging Electrical Skills Charter at the Senedd in Wales.
A brief history from 1890s to 2020s.
CIOB and CORBON combine forces
To elevate professional standards in Nigeria’s construction industry.
Amendment to the GB Energy Bill welcomed by ECA
Move prevents nationally-owned energy company from investing in solar panels produced by modern slavery.
Gregor Harvie argues that AI is state-sanctioned theft of IP.
Experimental AI housing target help for councils
Experimental AI could help councils meet housing targets by digitising records.
BSRIA Occupant Wellbeing survey BOW
Occupant satisfaction and wellbeing tool inc. physical environment, indoor facilities, functionality and accessibility.