BS 8414-1:2020
BS 8414-1:2020 - TC Fire performance of external cladding systems - Test method for non-loadbearing external cladding systems fixed to, and supported by, a masonry substrate. the latest update 2020, replaces the previous
BS 8414-1:2015 Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems applied to the masonry face of a building published in 2015, was withdrawn in Apr 2015 and amended by BS 8414-1:2015+A1:2017 in June 2017. It can be used to test rainscreen cladding and external wall insulation systems.
BS 8414-2:2015 Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame was published in 2015, then amended in 2017 by BS 8414-2:2015+A1:2017. 2017 and withdrawn in April 2020.
The British Standards Institution (BSI) is the UK National Standards Body (NSB). It publishes standards and provides a range of books, self-assessment tools, conferences and training services. It also represents UK economic and social interests in European and international standards organisations. British Standard (BS) publications are technical specifications or practices that can be used as guidance for the production of a product, carrying out a process or providing a service.
see also BS 8414 Fire performance of external cladding systems
[edit] Related articles on Designing Buildings
- Automatic fire detection and alarm systems, an introductory guide to components and systems BR 510.
- ACM cladding.
- BR135: Annex B. Performance criteria and classification method for BS 8414-2:2005.
- BS 5839-1.
- BS 9999: Code of practice for fire safety in the design, management and use of buildings.
- Building Research Establishment.
- Celotex RS5000 PIR insulation.
- Cladding for buildings.
- Consultation opens for code of practice for fire risk appraisal and assessment of external wall construction.
- Desktop study.
- EWS1 forms not required for buildings without cladding.
- External fire spread, Supplementary guidance to BR 187 incorporating probabilistic and time-based approaches.
- External wall insulation.
- Fire at the Cube, Bolton.
- Fire performance of external thermal insulation for walls of multistorey buildings, third edition (BR 135).
- Fire safety design.
- Grenfell Tower fire.
- The Regulatory Reform (Fire Safety) Order 2005.
- Understanding the factors affecting flashover of a fire in modern buildings.
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Electrical contractors need to understand the practical implications.
The real barrier to getting more value from digital technology.
Your guide to The Construction Reset at UKCW Birmingham.
Accommodating the Victorian and Edwardian working woman. Book review.
Rethinking passive fire protection in design
PFP demands the same level of design rigour as structure or services.
38% of Gen Zs feel safe when a fire door is wedged open.
Stunning images from around the world
Shortlist for CIOB’s Art of Building photography competition.
Guidance for conversion of traditional pre-1919 stone buildings.
Industrial heritage in the Ruhr
A marked difference to the fate of industrial landscapes in the UK.
Communities will be able to build their own clean energy.
Why diversity and inclusion matters for SMEs
CIOB’s D&I Charter shows how practical changes can support long-term growth.
Cut electricity bills to power growth
Coalition sends joint letter to the Chancellor.