Dew point
Air will generally include moisture in the form of water vapour.
Relative humidity (RH) is a measure of the water vapour density of air compared to the water vapour density for saturated air at the same temperature and pressure (that is, the maximum amount of moisture that air can “hold” at that temperature and pressure). It is expressed as a percentage.
RH = (actual water vapour density / saturation water vapour density) x 100
When air cools, it is less able to “hold” moisture, that is, the saturation water vapour density falls, and so relative humidity rises. When the relative humidity reaches 100%, the air will be saturated. This is described as the ‘dew point’ temperature, or the ‘saturation temperature’. If the air continues to cool, moisture will begin to condense. Where this condensate forms on a surface, it can be described as ‘dew’, hence the term ‘dew point’.
Understanding this phenomena is important in the design and construction of new buildings, and in the assessment of existing buildings, as the formation of condensation can be damaging, can affect comfort and can be a hazard to health.
Surface condensation occurs where water condenses on the exposed internal surfaces of a building, such as ‘cold’ windows.
Interstitial condensation occurs when the dew point temperature is reached within the fabric of the building, either on the surfaces of components that make up the fabric, or sometimes within the components themselves.
Condensation can cause:
- Mould growth which is a cause of respiratory allergies.
- Mildew.
- Staining.
- Corrosion and decay of the building fabric.
- Frost damage
- Poor performance of insulation.
- Damage to equipment.
- Slip hazards.
Software is available to help calculate dew points, particularly in relation to interstitial condensation, the position of which within the building fabric is crucial if potential problems are to be avoided.
[edit] Related articles on Designing Buildings
- Cavity wall.
- Cold bridge.
- Condensation.
- Dehumidification.
- Deliquescence point.
- Diagnosing the causes of dampness (GR 5 revised).
- Dry-bulb temperature.
- Humidity.
- Insulation specification.
- Interstitial condensation.
- Moisture.
- Psychometric chart.
- Saturation.
- Sling psychrometer.
- Solid wall insulation.
- Thermal comfort.
- Thermal indices.
- Temperature.
- Understanding dampness.
- Water vapour.
- Wet-bulb temperature.
Featured articles and news
Not buildings. Happy holiday from DB.
Improving government projects with data and AI
Enabling better outcomes, efficient modern delivery and influential leadership on government projects.
BSRIA Living Laboratory Innovation Challenge
Final days for submission, closing March 29.
Windows, their frames, forms, factors and functions.
The hidden subtleties of U-Value calculations
Different contexts and what to include as variables.
A brief run down with related articles.
Electrical sector calls for safer public EV charge points
Serious concerns about electrical safety in the public domain.
Building Blocks manifesto presented to parliament
Architects Declare call in for support of five critical policies.
The four elements of project management with APM
Analysis, expectations, collaborative communication and partnerships.
City of London launches Heritage Building Retrofit Toolkit
Empowering owners to initiate necessary adaptations.
Guidance on RAAC in listed buildings
Published by Purcell, endorsed by IHBC, SPAB and C20.
Learning from the past.
Reluctance to hire people with criminal convictions revealed
Employing People with Criminal Convictions Report.
Tackling unconscious bias; Women's History Month
Personal reflections, as the last week of March approaches.