Target fabric energy efficiency rate
Dwelling Fabric Energy Efficiency rates (DFEE) and Target Fabric Energy Efficiency rates (TFEE) were introduced by the 2013 edition of approved document L1A of the building regulations, 'Conservation of fuel and power in new dwellings', which came into force on 6 April 2014. The energy performance requirements of the 2013 edition have been strengthened to deliver a 6% carbon dioxide saving across the new homes build mix relative to the 2010 edition.
Dwelling Fabric Energy Efficiency rates and Target Fabric Energy Efficiency rates sit alongside the requirements for Target CO2 Emission Rates (TER) and Dwelling CO2 Emission Rates which were already part of the 2010 edition of the approved document.
The Target Fabric Energy Efficiency rate is the minimum energy performance requirement for a new dwelling approved by the Secretary of State in accordance with regulation 25 of the building regulations. It is expresses as the amount of energy demand in units of kilowatt-hours per square metre of floor area per year (kWh/(m^2.year).
The TFEE is derived from a notional dwelling of the same size and shape as the actual dwelling being constructed. A summary of the Part L 2013 notional dwelling is published in Table 4 of approved document L1A and the full detail is set out in the Standard Assessment Procedure (SAP 2012) Appendix R. However, following responses to the consultation on the 2013 changes, a further 15% is permitted to allow some design flexibility.
The Dwelling Fabric Energy Efficiency rate is the actual energy performance of the new dwelling.
In accordance with regulation 26A of the building regulations, the calculated Dwelling Fabric Energy Efficiency rate must not be greater than the Target Fabric Energy Efficiency rate.
If the actual dwelling is constructed entirely to the notional dwelling specifications it will meet the fabric energy efficiency targets, however, the notional dwelling is not prescriptive and developers are free to vary the specification, provided that TFEE rate is achieved or bettered.
Before work starts, the builder must calculate the DFEE rate of the dwelling as designed, to demonstrate it is not greater than the TFEE rate. The builder must give this design-based calculation to the Building Control Body (BCB) along with a list of specifications used.
When work is complete, the builder must notify the BCB of the DFEE rate and TFEE rate, and whether the building was constructed in accordance with the list of specifications submitted to the BCB before work started. A list of any changes to the design-stage list of specifications must be given to the BCB.
For a building that contains more than one dwelling (such as a terrace of houses or an apartment block), average rates can be used. An average cannot be calculated across separate multiple buildings on a site.
To guard against poor performance of individual elements, limiting fabric values are retained in Table 2 of approved document L1A and limiting building services efficiencies are set out in the Domestic Building Services Compliance Guide.
[edit] Related articles on Designing Buildings Wiki
- 2013 changes to the approved documents for part L of the building regulations.
- Approved document L.
- Approved documents.
- Building control body.
- Building Regulations.
- Dwelling emission rate.
- Fabric Energy Efficiency Standard FEES.
- Limiting fabric parameters.
- Standard assessment procedure.
- Target emission rate.
[edit] External references
This article contains public sector information licensed under the Open Government Licence v2.0 ref:
- Approved Document L1A, Conservation of fuel and power in new dwellings, 2013.
- DCLG circular New and amended Approved Documents and new Building Services Compliance Guides to support the energy efficiency requirements of the Building Regulations. 3 December 2013.
Featured articles and news
The UK's Modern Industrial Strategy: A 10 year plan
Previous consultation criticism, current key elements and general support with some persisting reservations.
Building Safety Regulator reforms
New roles, new staff and a new fast track service pave the way for a single construction regulator.
Architectural Technologist CPDs and Communications
CIAT CPD… and how you can do it!
Cooling centres and cool spaces
Managing extreme heat in cities by directing the public to places for heat stress relief and water sources.
Winter gardens: A brief history and warm variations
Extending the season with glass in different forms and terms.
Restoring Great Yarmouth's Winter Gardens
Transforming one of the least sustainable constructions imaginable.
Construction Skills Mission Board launch sector drive
Newly formed government and industry collaboration set strategy for recruiting an additional 100,000 construction workers a year.
New Architects Code comes into effect in September 2025
ARB Architects Code of Conduct and Practice available with ongoing consultation regarding guidance.
Welsh Skills Body (Medr) launches ambitious plan
The new skills body brings together funding and regulation of tertiary education and research for the devolved nation.
Paul Gandy FCIOB announced as next CIOB President
Former Tilbury Douglas CEO takes helm.
UK Infrastructure: A 10 Year Strategy. In brief with reactions
With the National Infrastructure and Service Transformation Authority (NISTA).
Ebenezer Howard: inventor of the garden city. Book review.
The Grenfell Tower fire, eight years on
A time to pause and reflect as Dubai tower block fire reported just before anniversary.
Airtightness Topic Guide BSRIA TG 27/2025
Explaining the basics of airtightness, what it is, why it's important, when it's required and how it's carried out.
Construction contract awards hit lowest point of 2025
Plummeting for second consecutive month, intensifying concerns for housing and infrastructure goals.
Understanding Mental Health in the Built Environment 2025
Examining the state of mental health in construction, shedding light on levels of stress, anxiety and depression.