The Control of Substances Hazardous to Health Regulations 2002 (COSHH) includes a legal requirement for workers using respiratory protective equipment (RPE), to have it fit tested by a competent person.
Fit testing is required to ensure that RPE provides adequate protection for the wearer. Masks and similar equipment rely on a good seal being achieved against the face. Any gaps around the seal will allow air to leak through.
A leading cause of leaks in RPE is facepieces that are poorly fitted. Fit testing helps ensure the most suitable type and size is selected for each individual.
Facial hair makes it more difficult, and in some cases impossible, to achieve a good seal. In such cases, alternative forms of RPE that do not rely on such a tight seal should be used.
Steps should be taken to ensure that the person conducting the RPE fit testing has been appropriately trained and qualified. The British Safety Industry Federation (BSIF), together with HSE and other industry stakeholders, have developed a competency scheme, Fit2Fit REP Fit Test Provider Accreditation Scheme.
NB in 2017, the Health and Safety Executive carried out tests on a number of filtering facepieces. Just five passed all the tests with no faults or failures:
- Two models had an isolated fault on a single sample.
- Three models had multiple faults, two of them serious.
- Four of the manufacturers included no, or limited, information on pre-use checks.
For more information see: Performance of FFP3 disposable respirators.
[edit] Related articles on Designing Buildings Wiki
- Air quality.
- Construction dust.
- Control of Substances Hazardous to Health (COSHH).
- Dust control systems.
- Ergonomics in construction.
- Filtering facepieces.
- First aider.
- Leaks in buildings.
- Performance of FFP3 disposable respirators.
- Personal protective equipment.
- Pollution.
- Site induction.
- The dust control systems market.
Featured articles and news
Investors in People: CIOB achieves gold
Reflecting a commitment to employees and members.
Scratching beneath the surface; a guide to selection.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
UK gov apprenticeship funding from April 2024
Brief summary the policy paper updated in March.
For the World Autism Awareness Month of April.
70+ experts appointed to public sector fire safety framework
The Fire Safety (FS2) Framework from LHC Procurement.
Project and programme management codes of practice
CIOB publications for built environment professionals.
The ECA Industry Awards 2024 now open !
Recognising the best in the electrotechnical industry.
Sustainable development concepts decade by decade.
The regenerative structural engineer
A call for design that will repair the natural world.
Buildings that mimic the restorative aspects found in nature.
CIAT publishes Principal Designer Competency Framework
For those considering applying for registration as a PD.
BSRIA Building Reg's guidance: The second staircase
An overview focusing on aspects which most affect the building services industry.
Design codes and pattern books
Harmonious proportions and golden sections.
Introducing or next Guest Editor Arun Baybars
Practising architect and design panel review member.
Quick summary by size, shape, test, material, use or bonding..