Wet bulb globe temperature
The Health and Safety Executive (HSE) suggest that wet bulb globe temperature WBGT (or the wet bulb globe temperature index) can be used to indicate the likelihood of heat stress.
Heat stress is a form of overheating that the occupants of a building may experience when the measures their bodies use to regulate internal temperature begin to fail. This can occur, for example, in buildings where an industrial process is being carried out, such as smelting, brick-firing, cooking and so on.
Heat stress is dependent on a number of factors, such as air temperature, metabolic rate, humidity, clothing, length of exposure, acclimatisation and so on. This means that it is a personal condition. Some occupants may experience heat stress whilst others may not.
Where humidity is high, or occupants are wearing protective clothing that cannot be adjusted or removed, the body may be unable to lose heat through the evaporation of sweat and so the individual may begin to experience elevated deep-body temperature, excessive sweating and increased heart rate. This can cause; dehydration, headache, difficulty concentrating, confusion, muscle cramp, heat rash, fatigue, giddiness, fainting, nausea, convulsions and ultimately, if it is allowed to persist, death.
The Workplace Regulations, the Management of Health and Safety at Work Regulations 1999 require that employers assess the risks to the health and safety of their workers, and take action where necessary and reasonably practicable.
Wet bulb globe temperature is a relatively simple indicator of heat stress. It includes components of natural wet-bulb temperature (tnw), globe temperature (tg) and air temperature (ta - dry bulb temperature).
- Where there is no solar radiation, wet bulb globe temperature = 0.7tnw + 0.3tg
- Where there is solar radiation, wet bulb globe temperature = 0.7tnw +0.2tg +0.1ta
The recorded values can be compared to recommended values for a specific metabolic rate and state of acclimatisation (found in BS EN 27243:1994, ISO 7243 Hot environments. Estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature)).
However, this will only provide an indication of whether heat stress is likely. Wet bulb globe temperature is a compromise, offering a measure that is relatively simple to assess, whilst still recording the key components of heat stress. Where the recomended values are exceeded, a more accurate measure such as Required Sweat Rate (also found in BS EN 12515) should be used for further assessment.
[edit] Find out more
[edit] Related articles on Designing Buildings Wiki
- Dry bulb temperature.
- Globe temperature.
- Heat stress.
- Operative temperature.
- Relative humidity.
- Temperature.
- Thermal comfort.
- Wet bulb temperature.
[edit] External references
- HSE, Heat stress.
- BS EN 27243:1994, ISO 7243 Hot environments. Estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature).
Featured articles and news
A transformative shift in the design, construction and management of built assets.
Apprenticeship announcement by the Prime Minister
Welcomed but with call for more actionable detail.
Heat pump announcements, what homeowners need to know
An 'ultimate guide to heat pumps' from a heating company.
Construction contract awards reach 7.1bn in February
Their highest level in seven months.
The journey to sustainability in heritage
Research is the key to better understanding.
Heritage approaches to adaptation, mitigation and loss.
Bridging the gap between policy, finance and installation.
Development on brownfield land
Definition, background, policy and the latest consultation.
With the Design Framework for Building Services.
Retrofit of Buildings, a CIOB Technical Publication
Pertinent technical issues, measures and the roles involved.
ECA joins HSE campaign to support mental health
Working Minds’ five simple steps based on risk assessment.
Mental health in the construction industry
Mental health issues in brief with related articles.
Transitional arrangements, Building Control and the BSR.
For pre-October buildings with substantial progress by April.
Why quality counts in domestic ventilation systems
From products, to systems to the installation.
Empowering the Future with CIOB Academy
Lifelong learning, upscaling, and reskilling for the built environment.