Solar heat gain in buildings can be beneficial in the winter, as it reduces the need for heating, but in the summer it can cause overheating.
The total solar heat transmittance into a space is the sum of the solar heat that is transmitted directly through its fabric (such as solar radiation transmitting through glass), and the solar heat that is absorbed by its fabric and then re-emitted into the enclosed space.
Total solar energy transmittance (gtot) relates to the performance of solar protection devices such as blinds and shutters and is the percentage of solar energy incident on the fabric of a blind or shutter that is transmitted to the interior of the building, including both the transmittance of the solar protection device itself and of the glazing.
According to the EN 14501 standard (Blinds and Shutters, Thermal and Visual Comfort, Performance Characteristics and Classification), it is measured on an index of 0 to 1. The closer the fabric’s index is to 0, the more efficient it is at protecting against heat and reducing solar energy; whereas an index of 1 means that all the incident solar radiation is transmitted.
Two methods are used for calculating the gtot of a solar protection device:
- Simplified calculation method: EN ISO 52022-1 (replacing EN 13363-1)
- Detailed calculation method: EN ISO 52022-3 (replacing EN 13363-2)
[edit] Find out more
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
Net zero electricity grids BSRIA guide NZG 5/2024
Outlining the changes needed to transition to net zero.
CIOB Global Student Challenge 2024
Universitas Indonesia wins for second year running.
New project and cultural district described in detail.
The nature of EPCs, crticism and inaccuracies.
History, issues and redesign.
From waste recycling to energy performance the hierchy.
An introduction to WERCS and WEEE responsibilities
Dealing 2 million tonnes of waste equipment a year.
Global BACS Market: analytics and optimisation
A BSRIA glance at building automation and control systems.
What it is and how to use it.
Types of insulating plaster by binder and insulant.
Investors in People: CIOB achieves gold
Reflecting a commitment to employees and members.
Scratching beneath the surface; a guide to selection.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
UK gov apprenticeship funding from April 2024
Brief summary the policy paper updated in March.
For the World Autism Awareness Month of April.