Regulated and unregulated energy consumption
|
Contents |
[edit] Introduction
A building’s energy consumption varies considerably according to the building’s function. Its total operational energy usage comprises regulated and unregulated energy. BREEAM broadly defines regulated and unregulated energy consumption as follows:
[edit] Regulated energy
‘Regulated energy is building energy consumption resulting from the specification of controlled, fixed building services and fittings, including space heating and cooling, hot water, ventilation, fans, pumps and lighting. Such energy uses are inherent in the design of a building.’
Designers may not be able to predict how the services and fittings will be used but they can design them to be as energy efficient as possible.
NB The Home Quality Mark One, Technical Manual SD239, England, Scotland & Wales, published by BRE in 2018 defines a regulated energy as; ‘…building energy consumption resulting from the specification of controlled, fixed building services and fittings, including space heating and cooling, hot water, ventilation and lighting.’
[edit] Unregulated energy
Unregulated energy is building energy consumption resulting from a system or process that is not ‘controlled’, ie energy consumption from systems in the building on which the Building Regulations do not impose a requirement. For example, this may include energy consumption from systems integral to the building and its operation, e.g. IT equipment, lifts, escalators, refrigeration systems, external lighting, ducted-fume cupboards, servers, printers, photocopiers, laptops, cooking, audio-visual equipment and other appliances.
Some buildings can have unregulated energy accounting for 50% of total energy use.
Unlike regulated energy use, unregulated energy consumption is usually only determined very late in the design process; it can also vary throughout the building lifecycle. This is because buildings may have different occupants or uses.
NB The Home Quality Mark One, Technical Manual SD239, England, Scotland & Wales, published by BRE in 2018 defines a unregulated energy as; ‘…the energy consumption of the home that is not ‘controlled’, i.e. energy consumption from aspects of the home on which Building Regulations do not impose a requirement. For the purposes of the HQM assessment, this includes energy associated with lighting, appliances and cooking.’
[edit] Building regulations
Designers usually demonstrate compliance with Approved Document L of the building regulations as evidence of a building’s energy efficiency. But this does not fully reflect reality, as regulated energy is only a part of the total. Although they can usually predict regulated energy usage, it becomes more difficult with unregulated energy as predicting user behaviour can be problematic. This means that designers should not be held accountable for total operational energy usage as it is something they can only partly influence.
[edit] Related articles on Designing Buildings Wiki
- Approved document L.
- BREEAM.
- Building Regulations.
- Energy performance certificates.
- Leadership in Energy and Environmental Design (LEED).
- New energy retrofit concept: ‘renovation trains’ for mass housing.
- Operational carbon.
- Performance gap.
- The code for sustainable homes.
[edit] External references
- Bonfield review.
- Energy Saving Trust.
- EU Energy Efficiency Directive.
- Part L (Conservation of fuel and power).
- Planning Portal – Energy Saving.
Featured articles and news
A safe energy transition – ECA launches a new Charter
Practical policy actions to speed up low carbon adoption while maintaining installation safety and competency.
Frank Duffy: Researcher and Practitioner
Reflections on achievements and relevance to the wider research and practice communities.
The 2026 Compliance Landscape: Fire doors
Why 'Business as Usual' is a Liability.
Cutting construction carbon footprint by caring for soil
Is construction neglecting one of the planet’s most powerful carbon stores and one of our greatest natural climate allies.
ARCHITECTURE: How's it progressing?
Archiblogger posing questions of a historical and contextual nature.
The roofscape of Hampstead Garden Suburb
Residents, architects and roofers need to understand detailing.
Homes, landlords. tenants and the new housing standards
What will it all mean?
The Architectural Technology podcast: Where it's AT
Catch-up on the latest episodes.
Edmundson Apprentice of the Year award 2026
Entries now open for this Electrical Contractors' Association award.
Traditional blue-grey slate from one of the oldest and largest UK slate quarries down in Cornwall.
There are plenty of sources with the potential to be redeveloped.
Change of use legislation breaths new life into buildings
A run down on Class MA of the General Permitted Development Order.
Solar generation in the historic environment
Success requires understanding each site in detail.
Level 6 Design, Construction and Management BSc
CIOB launches first-ever degree programme to develop the next generation of construction leaders.
Open for business as of April, with its 2026 prospectus and new pipeline of housing schemes.
The operational value of workforce health
Keeping projects moving. Incorporating unplanned absence and the importance of health, in operations.
A carbon case for indigenous slate
UK slate can offer clear embodied carbon advantages.
Costs and insolvencies mount for SMEs, despite growth
Construction sector under insolvency and wage bill pressure in part linked to National Insurance, says report.