Mean radiant temperature
All bodies exchange thermal radiation with their surroundings, depending on the difference in their surface temperatures and their emissivity. This radiant exchange is an important component of the thermal comfort that will be experienced by a person, particularly in places where there may be significant differences in radiant and air temperatures, for example, near a large window.
Other factors that influence thermal comfort include: environmental factors, such as air temperature, air velocity, relative humidity and the uniformity of conditions, as well as personal factors such as clothing, metabolic heat, acclimatisation, state of health, expectations, and even access to food and drink.
Mean radiant temperature (MRT) is a measure of the average temperature of the surfaces that surround a particular point, with which it will exchange thermal radiation. If the point is exposed to the outside, this may include the sky temperature and solar radiation.
The knowledge of surface geometries required to predict mean radiant temperature is very complex, particularly in elaborate spaces. However, mean radiant temperatures can be calculated by some proprietary software applications.
Mean radiant temperature can be measured using a globe thermometer. This is a hollow copper sphere painted matt black (to give it a high emissivity) with a temperature sensor at its centre.
From the temperature recorded, along with air velocity and air temperature (needed to account for convective heat exchange), the mean radiant temperature can be calculated:
MRT = globe temperature + 2.42 x air velocity in m/s (globe temperature – air temperature)
Note: This equation provides a very simplified rule of thumb. There are many different variations of this equation as it is dependent complex factors such as the size and emissivity of the globe thermometer. This particular example is taken from the Novalynx Corporation 2010, however, the units used in their equation appear to be incorrect, showing air velocity in cm/s rather than m/s. Thanks for pointing this out go to Dr Robert McLeod, Senior Lecturer Built Environment - Building Services Engineering, School of Environment and Technology at the University of Brighton.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
National Retrofit Hub unveils new guide
Digital Building Logbooks and Retrofit: An Introduction.
Top 50 firms awarded 52bn of projects in the last year
New engineering data shows.
Enhancing construction site reporting efficiency
Through digitisation and the digital revolution.
Noise in the built environment
BSRIA guide TG 20/2021.
17,000 people suffer conditions as a result of exposure to excessive noise at work.
Turning down the noise: Auditory health
A pervasive risk with far-reaching consequences.
UK Construction Week, London is here !
Debuting major international pavilions and much more.
Getting the most out of heat pumps and heating
How heat pumps work and how they work best.
Plumbing and heating for successful retrofit and renovation
Low temperature underfloor systems and heat pumps.
Cost-of-living crisis and home improvement plans
Starting on the right footing and top tips for projects.
Delays on construction projects
Types, mitigation and the acceleration of works.
From Chaucer to Fawlty Towers.
Electrotechnical excellence, now open for entries.
Net zero electricity grids BSRIA guide NZG 5/2024
Outlining the changes needed to transition to net zero.
CIOB Global Student Challenge 2024
Universitas Indonesia wins for second year running.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
Comments