U-values
Contents |
[edit] What are U-values?
U-values (sometimes referred to as heat transfer coefficients or thermal transmittances) are a measure of how effective the elements of a building's fabric are as insulators. That is, the degree to which they prevent heat from transmitting between the inside and the outside of a building.
The lower the U-value of an element of a building's fabric, the more slowly heat is able to transmit through it, and so the better it performs as an insulator.
Very broadly, the better (i.e. lower) the U-value of a building's fabric, the less energy is required to maintain comfortable conditions inside the building. As energy prices increase, and there is greater awareness of sustainability, performance measures such as U-values have become more important, and building standards (such as the Building Regulations) have required that lower and lower U-values are achieved. This has required changes in the design of buildings, both in the use of materials (such as insulation), the make-up of the building elements (such as cavity walls and double glazing), and the overall make up of a building's fabric (for example, reducing the proportion of glazing).
[edit] What is the difference between a U-value and an R-values?
R-values, which measure thermal resistance rather than thermal transmission, are often described as being the reciprocal of U-values, however, R-values do not include surface heat transfers.
[edit] What are the U-values of commonly building components?
U-values are measured in watts per square metre per kelvin (W/(m²K)). For example, a double glazed window with a U-value of 2.8, means that for every degree difference in temperature between the inside and outside of the window, 2.8 watts will be transmitted every square metre.
A range of typical U-values are:
- Solid brick wall: 2 W/(m²K)
- Cavity wall with no insulation: 1.5 W/(m²K).
- Insulated wall: 0.18 W/(m²K).
- Single glazing: 4.8 to 5.8 W/(m²K).
- Double glazing: 1.2 to 3.7 W/(m²K) depending on type.
- Triple glazing below: 1 W/(m²K).
- Solid timber door: 3 W/(m²K).
It is important to distinguish between U-values for materials (such as glass), or assemblies (such as windows, which have frames, air gaps, and so on), or elements (such as walls, which may have complex constructions comprising a number of different components).
[edit] What are the maximum U-values allowed?
Part L of the Building Regulations (Conservation of fuel and power) now prevents certain forms of construction by setting limiting standards (i.e. maximum U-values) for building elements. See Limiting fabric parameters for more information.
It should be noted however that these are maximum permitted values, the specification for the notional domestic building referred to in Part L1A has considerably lower values, for example:
- External wall: 0.18 W/(m²K).
- Floor: 0.13 W/(m²K).
- Roofs: 0.13 W/(m²K).
- Windows, roof windows, glazed rooflights and glazed doors: 1.4 W/(m²K).
See Standard Assessment Procedure SAP for more information.
[edit] How are U-values calculated?
The U value of an element (in W/(m²K)) can be calculated from sum of the thermal resistances (R-values in m²K/W) of the layers that make up the element plus its inside and outside surface thermal resistances (Ri and Ro).
U-value = 1 / (ΣR + Ri + Ro)
Where the thermal resistance of the layers of the element R = the thickness of each layer / the thermal conductivity of that layer (its k-value or lambda value (λ) in W/(mK)).
This can become a complicated calculation when there are a large number of layers, ventilated or unventilated cavities are introduced, or the element is inclined. Manufacturers will generally provide U-values for products that they supply. There are also a number of U-value calculators available online.
Calculation methods for U-values appropriate for demonstrating compliance with the building regulations are based on standards developed by the European Committee for Standardisation (CEN) and the International Organisation for Standardisation (ISO) and published as British Standards.
Whilst U-values are still used in the Building Regulations to set limiting standards for the elements of a building's fabric, the overall thermal performance of buildings is now assessed using more complex modelling procedures.
For non-domestic buildings, the Simplified Building Energy Model (SBEM) developed by the BRE for the Department for Communities and Local Government, determines the energy performance of a proposed building by comparing its annual energy use with that of a comparable notional building.
For dwellings, energy performance is assessed using the Standard Assessment Procedure (SAP).
NB: Whilst U-values and methods of modelling the thermal performance of buildings are invaluable in setting standards and providing a means of comparing alternative solutions, they are simplifications of reality, and performance in use rarely matches that which was predicted. Poor workmanship can result in reduced thermal resistance, as can poor detailing and the presence of water in insulating materials. See Insulation specification and performance gap for more information.
[edit] Related articles on Designing Buildings
- Air tightness in buildings.
- Building performance.
- Cavity wall insulation.
- Conduction.
- Conventions for calculating linear thermal transmittance and temperature factors.
- Conventions for U-value calculations (BR443 2e 2019).
- Double glazing v triple glazing.
- Emissivity.
- Free U-value calculators.
- g-value.
- k-value.
- Heat loss.
- Heat transfer.
- Insulation.
- Limiting fabric parameters.
- R-value.
- Standard Assessment Procedure SAP.
- Thermal admittance.
- Thermal bridge.
- Thermal mass.
- Thermal resistance.
- U-value conventions in practice: Worked examples using BR 443.
- U-What?
- What do design professionals need to know about U-value calculation conventions?
[edit] External references
Featured articles and news
From the UKs largest manufacturer and supplier of lime.
From mud bricks to smart concrete
A brief history from 7000BC to a future on the moon.
Regulator of Social Housing publishes latest fire safety report
Covering remediation of 11 metre plus social housing sector buildings.
Apartment and Duplex Defects Remediation Bill 2024
Approved for priority drafting by Government of Ireland.
The long list with in the frame of key historical events.
Competence frameworks for sustainability in the built environment
Code of practice, core criteria consultation draft for comment.
UK Net Zero Carbon Buildings Standard Sept update
Pilot version for testing and feedback on its adoption due.
New Floods Resilience Taskforce
With a wet met office autumn prediction.
National Retrofit Hub takeover of Net Zero stage
At Birmingham UK Construction Week in October.
AT Awards 2024 finalists announced
With more to come, prior to the Awards ceremony in October.
London construction cools as hotspots appear nationally
Increases in the East of England, Yorkshire and Scotland.
ARB proposals for a new Architects Code
Announced in the shadow of the final Grenfell Inquiry report.
Combining human creativity and tech innovation now and in the future
Building automation and control systems market study
BSRIA 2024 North America BACS software & services.
Impact of digital technology on productivity in construction
New CIOB academy guidance for companies of all sizes.
Demolition and retrofit approaches in Planning Policy
MHCLG demolition and retrofit survey to inform future updates to national planning policy.
Expert taskforce to spearhead new, new town generation
Sir Michael Lyons given 12 months for recommendations.
Government policy statement on new towns
A coded vision for a new generation of new towns.
Comments
[edit] To make a comment about this article, or to suggest changes, click 'Add a comment' above. Separate your comments from any existing comments by inserting a horizontal line.