<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="https://www.designingbuildings.co.uk/skins/common/feed.css?301"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www.designingbuildings.co.uk/w/index.php?feed=atom&amp;target=EudoreFlood_Barrierstore&amp;title=Special%3AContributions%2FEudoreFlood_Barrierstore</id>
		<title>Designing Buildings - User contributions [en]</title>
		<link rel="self" type="application/atom+xml" href="https://www.designingbuildings.co.uk/w/index.php?feed=atom&amp;target=EudoreFlood_Barrierstore&amp;title=Special%3AContributions%2FEudoreFlood_Barrierstore"/>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/wiki/Special:Contributions/EudoreFlood_Barrierstore"/>
		<updated>2026-11-20T12:02:05Z</updated>
		<subtitle>From Designing Buildings</subtitle>
		<generator>MediaWiki 1.17.4</generator>

	<entry>
		<id>https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg</id>
		<title>File:Eudore-type40-structural-model-source-page.jpg</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg"/>
				<updated>2026-11-20T10:39:14Z</updated>
		
		<summary type="html">&lt;p&gt;EudoreFlood Barrierstore: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Eudore supports flood barrier performance claims with published structural calculations, measured test results and a recorded manufacturer water-retention trial. Each record identifies a particular assembly and set of conditions. Reading those details together allows a buyer to examine the basis for a proposed protection height.&lt;br /&gt;
&lt;br /&gt;
By LEVI.CUI · Eudore test participant&amp;lt;br /&amp;gt;&lt;br /&gt;
Technical article prepared November 19, 2026. Manufacturer test video filmed October 15, 2026.&lt;br /&gt;
&lt;br /&gt;
I participated in the Eudore test discussed below. In this article I explain what our published documents report, why we use both calculations and physical testing, and how a contractor can match that evidence to an opening. My account of the manufacturer trial is identified separately from the results in the linked reports.&lt;br /&gt;
&lt;br /&gt;
== Why we use calculations and water tests ==&lt;br /&gt;
&lt;br /&gt;
A flood barrier has to carry water pressure while maintaining contact along its sealing interfaces. The engineering review therefore needs to consider panels, posts, braces, fixings and the supporting foundation. A physical water test also examines the assembled sealing arrangement.&lt;br /&gt;
&lt;br /&gt;
The Type 40 calculation uses p = γH at the base and F = ½γH² per meter of wall. With its adopted water unit weight of 10 kN/m³, a 2.0 m retained depth gives 20 kPa base pressure and 20 kN thrust per meter. The square term explains why water depth matters so much. At the same width, the illustrative thrust at 1.9 m is about 2.51 times that at 1.2 m. This comparison explains loading; the project design still requires the specified geometry and supports. See [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf#page=3 the hydrostatic model on page 3].&lt;br /&gt;
&lt;br /&gt;
Calculations assess stresses, movements and load paths. A water test supplies observations of the assembled system under the stated test conditions. We publish both so the reader can examine the assumptions as well as the recorded behavior.&lt;br /&gt;
&lt;br /&gt;
== What the structural calculation documents establish ==&lt;br /&gt;
&lt;br /&gt;
The nine-page [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf Type 40 structural calculation report] is an English translation for a Thailand river-channel configuration. It names the calculation organization as the Institute of Building Industry, North China Industrial Testing Center, using a descriptive English translation. It records calculation and check dates of October 18 and 19, 2026, with signature and seal images on page 9.&lt;br /&gt;
&lt;br /&gt;
The modeled case retains 2.0 m of water across a 2.0 m overall bay, with a center post giving 1.0 m post spacing and rear braces at 750 mm spacing. The panel section is approximately 40 × 222.3 mm with 2.0 mm walls. Selected values in its page 8 summary are reproduced below as reported.&lt;br /&gt;
&lt;br /&gt;
Selected Type 40 calculated checks, source page 8&lt;br /&gt;
&lt;br /&gt;
Check Reported value Reported comparison&lt;br /&gt;
&lt;br /&gt;
Panel bending stress, 1.0 m span&lt;br /&gt;
&lt;br /&gt;
13.1 N/mm²&lt;br /&gt;
&lt;br /&gt;
90 N/mm² adopted design strength&lt;br /&gt;
&lt;br /&gt;
Panel deflection, 1.0 m span&lt;br /&gt;
&lt;br /&gt;
0.70 mm&lt;br /&gt;
&lt;br /&gt;
5.0 mm limit&lt;br /&gt;
&lt;br /&gt;
Center-post bending stress&lt;br /&gt;
&lt;br /&gt;
109.6 N/mm²&lt;br /&gt;
&lt;br /&gt;
200 N/mm² adopted design strength&lt;br /&gt;
&lt;br /&gt;
Center-post deflection&lt;br /&gt;
&lt;br /&gt;
5.2 mm&lt;br /&gt;
&lt;br /&gt;
6.3 mm limit&lt;br /&gt;
&lt;br /&gt;
The report records satisfactory checks for its stated arrangement. It considers hydrostatic pressure and requires separate assessment of waves, vessel wakes and debris impact. Its foundation notes also require site-specific anchorage and concrete design. The translation flags inconsistencies in the source’s material-strength wording and base-restraint descriptions. Those points should be resolved against the original engineering record before a project relies on the model.&lt;br /&gt;
&lt;br /&gt;
[[File:Eudore-type40-structural-model-source-page.jpg|link=https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf#page=4]] Source page 4 of the Type 40 calculation translation. The diagram belongs to its specified 2.0 m hydrostatic design case. Open the complete linked report for assumptions and results.&lt;br /&gt;
&lt;br /&gt;
The earlier, 39-page [https://www.floodbarrierstore.com/wp-content/uploads/2024/06/Calculation-Sheet.pdf Calculation Sheet] provides a separate 3D3S Design 2021.1 model with nodes, members, loads, displacements and check results. Section 9.3.4 on its final page states a 1.225 m retaining height and 2 m middle-column span for the listed checks. It is a configuration reference with its own assumptions. The PDF does not establish the same identifiable calculation organization as the later Type 40 document.&lt;br /&gt;
&lt;br /&gt;
For taller project options, review our [https://www.floodbarrierstore.com/aluminum-flood-barriers-up-to-2-meters/ aluminum flood barriers up to 2 meters] and request the calculations matching the actual quoted section, span, posts and braces.&lt;br /&gt;
&lt;br /&gt;
== What the mechanical-properties report measured at 1.2 m ==&lt;br /&gt;
&lt;br /&gt;
[https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Mechanical-Properties-Testing-Report-pdf.pdf#page=1 Mechanical Properties Testing Report BB1JZL-20250032] identifies the Civil Engineering and Transportation Inspection Center, South China University of Technology. It lists test date April 23, 2025 and report date May 26, 2025. The sample is WBa20250423002a1, described as 6063-T6, 7000 × 1200 × 40 mm.&lt;br /&gt;
&lt;br /&gt;
Measured values reported on page 1 at 1.2 m head&lt;br /&gt;
&lt;br /&gt;
Measurement Result Report requirement&lt;br /&gt;
&lt;br /&gt;
Column 1 / Column 2 stress&lt;br /&gt;
&lt;br /&gt;
33.72 / 32.14 MPa&lt;br /&gt;
&lt;br /&gt;
Each ≤215 MPa&lt;br /&gt;
&lt;br /&gt;
Water-deflector stress&lt;br /&gt;
&lt;br /&gt;
48.23 MPa&lt;br /&gt;
&lt;br /&gt;
≤215 MPa&lt;br /&gt;
&lt;br /&gt;
Column 1 / Column 2 deflection&lt;br /&gt;
&lt;br /&gt;
1.25 / 0.97 mm&lt;br /&gt;
&lt;br /&gt;
Each ≤5 mm&lt;br /&gt;
&lt;br /&gt;
Leakage&lt;br /&gt;
&lt;br /&gt;
0.030 m³/min&lt;br /&gt;
&lt;br /&gt;
No threshold listed in this row&lt;br /&gt;
&lt;br /&gt;
The report concludes that the stated stress and column-deflection requirements are satisfied. It also records 0.018 m³/min leakage at 0.8 m head. The units are important: 0.030 m³/min converts to 30 L/min for that reported measurement. A comparison with another leakage figure requires matching the method, units and reference length.&lt;br /&gt;
&lt;br /&gt;
== Flow, wave and static-water results in the performance report ==&lt;br /&gt;
&lt;br /&gt;
The seven-page [https://www.floodbarrierstore.com/wp-content/uploads/2024/11/Test-Report.pdf performance Test Report] describes a commissioned witnessed test referring to BSI PAS 1188-4:2014 and client requirements. It identifies a DSC-095 assembly of 3000 × 1600 × 40 mm and lists 2 mm aluminum walls and EPDM seals on page 3.&lt;br /&gt;
&lt;br /&gt;
Results transcribed from Test-Report.pdf, pages 4–5&lt;br /&gt;
&lt;br /&gt;
Condition and duration Leakage Deformation&lt;br /&gt;
&lt;br /&gt;
Flow, 0.85 m, 30 min&lt;br /&gt;
&lt;br /&gt;
0.27 L/h/m&lt;br /&gt;
&lt;br /&gt;
0.53 mm&lt;br /&gt;
&lt;br /&gt;
Wave, 1.10 m, 15 min&lt;br /&gt;
&lt;br /&gt;
0.56 L/h/m&lt;br /&gt;
&lt;br /&gt;
0.62 mm&lt;br /&gt;
&lt;br /&gt;
Static water, 1.50 m, 60 h&lt;br /&gt;
&lt;br /&gt;
0.51 L/h/m&lt;br /&gt;
&lt;br /&gt;
0.46 mm&lt;br /&gt;
&lt;br /&gt;
The report marks these results as meeting its stated requirement of less than 40 L/h/m. This is useful performance evidence for the specimen and method recorded. The published English file uses “Interte” in its main header and “Intertek” elsewhere, with differing identifier strings on later pages. A formal project submission should use an issuer-confirmed complete version. The numbers above retain the source units and page references.&lt;br /&gt;
&lt;br /&gt;
== Our 1.9 m, 48-hour manufacturer water-retention trial ==&lt;br /&gt;
&lt;br /&gt;
A U.S. general contractor considering barriers for 78 garage doors wanted evidence for a 1.2 m protection requirement before ordering. I participated in Eudore’s manufacturer test, filmed on October 15, 2026. Our team reports retaining water at 1.9 m for 48 hours with no observed leakage through the tested assembly.&lt;br /&gt;
&lt;br /&gt;
The setup used nine stacked panels with a total height of 1.98 m, a reported barrier length of 2.4 m, a 50 mm profile cross-sectional width and 2 mm aluminum wall thickness. The actual water depth was 1.9 m. These are the manufacturer-confirmed trial dimensions.&lt;br /&gt;
&lt;br /&gt;
[[File:Eudore-type40-structural-model-source-page.jpg|link=File:Eudore-type40-structural-model-source-page.jpg]] Manufacturer test footage, October 15, 2026. [https://www.youtube.com/watch?v=rxHKUxbipsw Watch on YouTube].&lt;br /&gt;
&lt;br /&gt;
The short video shows the setup and water-facing views. The depth, 48-hour duration and observation are Eudore’s account of the trial. The 50 mm trial section differs from the 40 mm sections in the reports. The video provides additional product evidence, while each calculation and test report retains its own scope.&lt;br /&gt;
&lt;br /&gt;
== How we turn the evidence into a project review ==&lt;br /&gt;
&lt;br /&gt;
For a contractor buying [https://www.floodbarrierstore.com/aluminum-flood-barriers-for-garage-doors/ garage door flood barriers], a useful submittal connects the proposed opening to a defined configuration and the applicable documents. It should identify panel section and wall thickness, clear span, post and brace spacing, anchors, concrete conditions and design water level. Installation and seal-compression details belong in that review.&lt;br /&gt;
&lt;br /&gt;
A 2.0 m structural calculation, a 1.5 m static-water report and a 1.9 m manufacturer trial answer different questions. Their combined value is that a reviewer can trace the assumptions, measured outcomes and assembled example. Applying them to a new opening requires checking the differences.&lt;br /&gt;
&lt;br /&gt;
Eudore / Flood Barrier Store, the brand of Shenzhen Aodeke Optoelectronics Co., Ltd. in Shenzhen, publishes these files through its [https://www.floodbarrierstore.com/technical-resources/ technical resources]. For other access points, explore our [https://www.floodbarrierstore.com/custom-aluminum-flood-barriersfor-garage-doors-homes-businesses/ custom aluminum flood barriers for homes and entrances]. [https://www.floodbarrierstore.com/contact/ Send an opening schedule, photographs and required flood height] to request a configuration and supporting evidence.&lt;br /&gt;
&lt;br /&gt;
== Source documents and author ==&lt;br /&gt;
&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Mechanical-Properties-Testing-Report-pdf.pdf Mechanical Properties Testing Report], BB1JZL-20250032, pages 1–3.&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf Type 40 Structural Calculation Report], calculation/check dates October 18–19, 2026, pages 1–9.&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2024/06/Calculation-Sheet.pdf Calculation Sheet], 39 pages, especially section 9.3.4.&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2024/11/Test-Report.pdf DSC-095 performance Test Report], 7 pages, especially pages 2–5.&lt;br /&gt;
# [https://www.youtube.com/watch?v=rxHKUxbipsw Eudore manufacturer trial video], filmed October 15, 2026.&lt;br /&gt;
&lt;br /&gt;
LEVI.CUI is the author and an Eudore participant in the manufacturer water-retention trial described here. The institutional test and calculation findings are attributed to their documents. This article is Eudore’s technical explanation of its published evidence.&lt;/div&gt;</summary>
		<author><name>EudoreFlood Barrierstore</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg</id>
		<title>File:Eudore-type40-structural-model-source-page.jpg</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg"/>
				<updated>2026-11-20T10:38:13Z</updated>
		
		<summary type="html">&lt;p&gt;EudoreFlood Barrierstore: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Eudore supports flood barrier performance claims with published structural calculations, measured test results and a recorded manufacturer water-retention trial. Each record identifies a particular assembly and set of conditions. Reading those details together allows a buyer to examine the basis for a proposed protection height.&lt;br /&gt;
&lt;br /&gt;
By LEVI.CUI · Eudore test participant&amp;lt;br /&amp;gt;&lt;br /&gt;
Technical article prepared November 19, 2026. Manufacturer test video filmed October 15, 2026.&lt;br /&gt;
&lt;br /&gt;
I participated in the Eudore test discussed below. In this article I explain what our published documents report, why we use both calculations and physical testing, and how a contractor can match that evidence to an opening. My account of the manufacturer trial is identified separately from the results in the linked reports.&lt;br /&gt;
&lt;br /&gt;
== Why we use calculations and water tests ==&lt;br /&gt;
&lt;br /&gt;
A flood barrier has to carry water pressure while maintaining contact along its sealing interfaces. The engineering review therefore needs to consider panels, posts, braces, fixings and the supporting foundation. A physical water test also examines the assembled sealing arrangement.&lt;br /&gt;
&lt;br /&gt;
The Type 40 calculation uses p = γH at the base and F = ½γH² per meter of wall. With its adopted water unit weight of 10 kN/m³, a 2.0 m retained depth gives 20 kPa base pressure and 20 kN thrust per meter. The square term explains why water depth matters so much. At the same width, the illustrative thrust at 1.9 m is about 2.51 times that at 1.2 m. This comparison explains loading; the project design still requires the specified geometry and supports. See [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf#page=3 the hydrostatic model on page 3].&lt;br /&gt;
&lt;br /&gt;
Calculations assess stresses, movements and load paths. A water test supplies observations of the assembled system under the stated test conditions. We publish both so the reader can examine the assumptions as well as the recorded behavior.&lt;br /&gt;
&lt;br /&gt;
== What the structural calculation documents establish ==&lt;br /&gt;
&lt;br /&gt;
The nine-page [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf Type 40 structural calculation report] is an English translation for a Thailand river-channel configuration. It names the calculation organization as the Institute of Building Industry, North China Industrial Testing Center, using a descriptive English translation. It records calculation and check dates of October 18 and 19, 2026, with signature and seal images on page 9.&lt;br /&gt;
&lt;br /&gt;
The modeled case retains 2.0 m of water across a 2.0 m overall bay, with a center post giving 1.0 m post spacing and rear braces at 750 mm spacing. The panel section is approximately 40 × 222.3 mm with 2.0 mm walls. Selected values in its page 8 summary are reproduced below as reported.&lt;br /&gt;
&lt;br /&gt;
Selected Type 40 calculated checks, source page 8&lt;br /&gt;
&lt;br /&gt;
Check Reported value Reported comparison&lt;br /&gt;
&lt;br /&gt;
Panel bending stress, 1.0 m span&lt;br /&gt;
&lt;br /&gt;
13.1 N/mm²&lt;br /&gt;
&lt;br /&gt;
90 N/mm² adopted design strength&lt;br /&gt;
&lt;br /&gt;
Panel deflection, 1.0 m span&lt;br /&gt;
&lt;br /&gt;
0.70 mm&lt;br /&gt;
&lt;br /&gt;
5.0 mm limit&lt;br /&gt;
&lt;br /&gt;
Center-post bending stress&lt;br /&gt;
&lt;br /&gt;
109.6 N/mm²&lt;br /&gt;
&lt;br /&gt;
200 N/mm² adopted design strength&lt;br /&gt;
&lt;br /&gt;
Center-post deflection&lt;br /&gt;
&lt;br /&gt;
5.2 mm&lt;br /&gt;
&lt;br /&gt;
6.3 mm limit&lt;br /&gt;
&lt;br /&gt;
The report records satisfactory checks for its stated arrangement. It considers hydrostatic pressure and requires separate assessment of waves, vessel wakes and debris impact. Its foundation notes also require site-specific anchorage and concrete design. The translation flags inconsistencies in the source’s material-strength wording and base-restraint descriptions. Those points should be resolved against the original engineering record before a project relies on the model.&lt;br /&gt;
&lt;br /&gt;
[[File:eudore-type40-structural-model-source-page.jpg|893px|link=https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf#page=4]] Source page 4 of the Type 40 calculation translation. The diagram belongs to its specified 2.0 m hydrostatic design case. Open the complete linked report for assumptions and results.&lt;br /&gt;
&lt;br /&gt;
The earlier, 39-page [https://www.floodbarrierstore.com/wp-content/uploads/2024/06/Calculation-Sheet.pdf Calculation Sheet] provides a separate 3D3S Design 2021.1 model with nodes, members, loads, displacements and check results. Section 9.3.4 on its final page states a 1.225 m retaining height and 2 m middle-column span for the listed checks. It is a configuration reference with its own assumptions. The PDF does not establish the same identifiable calculation organization as the later Type 40 document.&lt;br /&gt;
&lt;br /&gt;
For taller project options, review our [https://www.floodbarrierstore.com/aluminum-flood-barriers-up-to-2-meters/ aluminum flood barriers up to 2 meters] and request the calculations matching the actual quoted section, span, posts and braces.&lt;br /&gt;
&lt;br /&gt;
== What the mechanical-properties report measured at 1.2 m ==&lt;br /&gt;
&lt;br /&gt;
[https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Mechanical-Properties-Testing-Report-pdf.pdf#page=1 Mechanical Properties Testing Report BB1JZL-20250032] identifies the Civil Engineering and Transportation Inspection Center, South China University of Technology. It lists test date April 23, 2025 and report date May 26, 2025. The sample is WBa20250423002a1, described as 6063-T6, 7000 × 1200 × 40 mm.&lt;br /&gt;
&lt;br /&gt;
Measured values reported on page 1 at 1.2 m head&lt;br /&gt;
&lt;br /&gt;
Measurement Result Report requirement&lt;br /&gt;
&lt;br /&gt;
Column 1 / Column 2 stress&lt;br /&gt;
&lt;br /&gt;
33.72 / 32.14 MPa&lt;br /&gt;
&lt;br /&gt;
Each ≤215 MPa&lt;br /&gt;
&lt;br /&gt;
Water-deflector stress&lt;br /&gt;
&lt;br /&gt;
48.23 MPa&lt;br /&gt;
&lt;br /&gt;
≤215 MPa&lt;br /&gt;
&lt;br /&gt;
Column 1 / Column 2 deflection&lt;br /&gt;
&lt;br /&gt;
1.25 / 0.97 mm&lt;br /&gt;
&lt;br /&gt;
Each ≤5 mm&lt;br /&gt;
&lt;br /&gt;
Leakage&lt;br /&gt;
&lt;br /&gt;
0.030 m³/min&lt;br /&gt;
&lt;br /&gt;
No threshold listed in this row&lt;br /&gt;
&lt;br /&gt;
The report concludes that the stated stress and column-deflection requirements are satisfied. It also records 0.018 m³/min leakage at 0.8 m head. The units are important: 0.030 m³/min converts to 30 L/min for that reported measurement. A comparison with another leakage figure requires matching the method, units and reference length.&lt;br /&gt;
&lt;br /&gt;
== Flow, wave and static-water results in the performance report ==&lt;br /&gt;
&lt;br /&gt;
The seven-page [https://www.floodbarrierstore.com/wp-content/uploads/2024/11/Test-Report.pdf performance Test Report] describes a commissioned witnessed test referring to BSI PAS 1188-4:2014 and client requirements. It identifies a DSC-095 assembly of 3000 × 1600 × 40 mm and lists 2 mm aluminum walls and EPDM seals on page 3.&lt;br /&gt;
&lt;br /&gt;
Results transcribed from Test-Report.pdf, pages 4–5&lt;br /&gt;
&lt;br /&gt;
Condition and duration Leakage Deformation&lt;br /&gt;
&lt;br /&gt;
Flow, 0.85 m, 30 min&lt;br /&gt;
&lt;br /&gt;
0.27 L/h/m&lt;br /&gt;
&lt;br /&gt;
0.53 mm&lt;br /&gt;
&lt;br /&gt;
Wave, 1.10 m, 15 min&lt;br /&gt;
&lt;br /&gt;
0.56 L/h/m&lt;br /&gt;
&lt;br /&gt;
0.62 mm&lt;br /&gt;
&lt;br /&gt;
Static water, 1.50 m, 60 h&lt;br /&gt;
&lt;br /&gt;
0.51 L/h/m&lt;br /&gt;
&lt;br /&gt;
0.46 mm&lt;br /&gt;
&lt;br /&gt;
The report marks these results as meeting its stated requirement of less than 40 L/h/m. This is useful performance evidence for the specimen and method recorded. The published English file uses “Interte” in its main header and “Intertek” elsewhere, with differing identifier strings on later pages. A formal project submission should use an issuer-confirmed complete version. The numbers above retain the source units and page references.&lt;br /&gt;
&lt;br /&gt;
== Our 1.9 m, 48-hour manufacturer water-retention trial ==&lt;br /&gt;
&lt;br /&gt;
A U.S. general contractor considering barriers for 78 garage doors wanted evidence for a 1.2 m protection requirement before ordering. I participated in Eudore’s manufacturer test, filmed on October 15, 2026. Our team reports retaining water at 1.9 m for 48 hours with no observed leakage through the tested assembly.&lt;br /&gt;
&lt;br /&gt;
The setup used nine stacked panels with a total height of 1.98 m, a reported barrier length of 2.4 m, a 50 mm profile cross-sectional width and 2 mm aluminum wall thickness. The actual water depth was 1.9 m. These are the manufacturer-confirmed trial dimensions.&lt;br /&gt;
&lt;br /&gt;
[[File:Eudore-type40-structural-model-source-page.jpg]] Manufacturer test footage, October 15, 2026. [https://www.youtube.com/watch?v=rxHKUxbipsw Watch on YouTube].&lt;br /&gt;
&lt;br /&gt;
The short video shows the setup and water-facing views. The depth, 48-hour duration and observation are Eudore’s account of the trial. The 50 mm trial section differs from the 40 mm sections in the reports. The video provides additional product evidence, while each calculation and test report retains its own scope.&lt;br /&gt;
&lt;br /&gt;
== How we turn the evidence into a project review ==&lt;br /&gt;
&lt;br /&gt;
For a contractor buying [https://www.floodbarrierstore.com/aluminum-flood-barriers-for-garage-doors/ garage door flood barriers], a useful submittal connects the proposed opening to a defined configuration and the applicable documents. It should identify panel section and wall thickness, clear span, post and brace spacing, anchors, concrete conditions and design water level. Installation and seal-compression details belong in that review.&lt;br /&gt;
&lt;br /&gt;
A 2.0 m structural calculation, a 1.5 m static-water report and a 1.9 m manufacturer trial answer different questions. Their combined value is that a reviewer can trace the assumptions, measured outcomes and assembled example. Applying them to a new opening requires checking the differences.&lt;br /&gt;
&lt;br /&gt;
Eudore / Flood Barrier Store, the brand of Shenzhen Aodeke Optoelectronics Co., Ltd. in Shenzhen, publishes these files through its [https://www.floodbarrierstore.com/technical-resources/ technical resources]. For other access points, explore our [https://www.floodbarrierstore.com/custom-aluminum-flood-barriersfor-garage-doors-homes-businesses/ custom aluminum flood barriers for homes and entrances]. [https://www.floodbarrierstore.com/contact/ Send an opening schedule, photographs and required flood height] to request a configuration and supporting evidence.&lt;br /&gt;
&lt;br /&gt;
== Source documents and author ==&lt;br /&gt;
&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Mechanical-Properties-Testing-Report-pdf.pdf Mechanical Properties Testing Report], BB1JZL-20250032, pages 1–3.&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2026/11/Aluminum_Alloy_Flood_Barrier_Structural_Calculation_Report.pdf Type 40 Structural Calculation Report], calculation/check dates October 18–19, 2026, pages 1–9.&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2024/06/Calculation-Sheet.pdf Calculation Sheet], 39 pages, especially section 9.3.4.&lt;br /&gt;
# [https://www.floodbarrierstore.com/wp-content/uploads/2024/11/Test-Report.pdf DSC-095 performance Test Report], 7 pages, especially pages 2–5.&lt;br /&gt;
# [https://www.youtube.com/watch?v=rxHKUxbipsw Eudore manufacturer trial video], filmed October 15, 2026.&lt;br /&gt;
&lt;br /&gt;
LEVI.CUI is the author and an Eudore participant in the manufacturer water-retention trial described here. The institutional test and calculation findings are attributed to their documents. This article is Eudore’s technical explanation of its published evidence.&lt;/div&gt;</summary>
		<author><name>EudoreFlood Barrierstore</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg</id>
		<title>File:Eudore-type40-structural-model-source-page.jpg</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg"/>
				<updated>2026-11-20T10:35:53Z</updated>
		
		<summary type="html">&lt;p&gt;EudoreFlood Barrierstore: uploaded a new version of &amp;amp;quot;File:Eudore-type40-structural-model-source-page.jpg&amp;amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>EudoreFlood Barrierstore</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg</id>
		<title>File:Eudore-type40-structural-model-source-page.jpg</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/wiki/File:Eudore-type40-structural-model-source-page.jpg"/>
				<updated>2026-11-20T10:34:32Z</updated>
		
		<summary type="html">&lt;p&gt;EudoreFlood Barrierstore: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>EudoreFlood Barrierstore</name></author>	</entry>

	</feed>