<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="https://www.designingbuildings.co.uk/skins/common/feed.css?301"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www.designingbuildings.co.uk/w/index.php?action=history&amp;feed=atom&amp;title=R404A_phase_out</id>
		<title>R404A phase out - Revision history</title>
		<link rel="self" type="application/atom+xml" href="https://www.designingbuildings.co.uk/w/index.php?action=history&amp;feed=atom&amp;title=R404A_phase_out"/>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;action=history"/>
		<updated>2026-04-06T11:13:57Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.17.4</generator>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=221579&amp;oldid=prev</id>
		<title>Editor at 16:34, 28 December 2021</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=221579&amp;oldid=prev"/>
				<updated>2021-12-28T16:34:11Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 16:34, 28 December 2021&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 39:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 39:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Unprocessed product that has been recovered from a system should not be stored longer than 12 months. After that time, it should be designated as hazardous waste and disposed of according to the proper environmental regulations.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Unprocessed product that has been recovered from a system should not be stored longer than 12 months. After that time, it should be designated as hazardous waste and disposed of according to the proper environmental regulations.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Related articles on Designing Buildings &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;Wiki &lt;/del&gt;=&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;--[[User:Heidi_Schwartz|Heidi Schwartz]]&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&amp;#160;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Related articles on Designing Buildings =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* EMEA compressor market 2020 - 2023.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* EMEA compressor market 2020 - 2023.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Editor</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=211084&amp;oldid=prev</id>
		<title>Editor at 10:31, 16 August 2021</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=211084&amp;oldid=prev"/>
				<updated>2021-08-16T10:31:44Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 10:31, 16 August 2021&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, it is a highly potent greenhouse gas&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;. It is also ozone depleting&lt;/del&gt;.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, it is a highly potent greenhouse gas.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Editor</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=211082&amp;oldid=prev</id>
		<title>Editor: Reverted edits by 195.235.183.2 (talk) to last revision by Designing Buildings</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=211082&amp;oldid=prev"/>
				<updated>2021-08-16T10:22:48Z</updated>
		
		<summary type="html">&lt;p&gt;Reverted edits by &lt;a href=&quot;/wiki/Special:Contributions/195.235.183.2&quot; title=&quot;Special:Contributions/195.235.183.2&quot;&gt;195.235.183.2&lt;/a&gt; (&lt;a href=&quot;/wiki/User_talk:195.235.183.2&quot;&gt;talk&lt;/a&gt;) to last revision by &lt;a href=&quot;/wiki/User:Designing_Buildings&quot; title=&quot;User:Designing Buildings&quot;&gt;Designing Buildings&lt;/a&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 10:22, 16 August 2021&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, it is a highly potent greenhouse gas. &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;R404a &lt;/del&gt;is &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;NON-&lt;/del&gt;ozone depleting.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, it is a highly potent greenhouse gas. &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;It &lt;/ins&gt;is &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;also &lt;/ins&gt;ozone depleting.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Editor</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=211079&amp;oldid=prev</id>
		<title>195.235.183.2 at 10:10, 16 August 2021</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=211079&amp;oldid=prev"/>
				<updated>2021-08-16T10:10:17Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 10:10, 16 August 2021&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, it is a highly potent greenhouse gas. &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;It &lt;/del&gt;is &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;also &lt;/del&gt;ozone depleting.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, it is a highly potent greenhouse gas. &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;R404a &lt;/ins&gt;is &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;NON-&lt;/ins&gt;ozone depleting.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>[IP address hidden]</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=197029&amp;oldid=prev</id>
		<title>Designing Buildings at 09:51, 5 March 2021</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=197029&amp;oldid=prev"/>
				<updated>2021-03-05T09:51:22Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 09:51, 5 March 2021&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Introduction =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;known as &lt;/del&gt;a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;R404A &lt;/del&gt;is &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;considered an ozone depleting, &lt;/del&gt;highly potent greenhouse gas.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;R404A is a type of fluorinated gas (F gas) that is a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;it &lt;/ins&gt;is &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;a &lt;/ins&gt;highly potent greenhouse gas&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;. It is also ozone depleting&lt;/ins&gt;.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Background on 404A =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 11:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 11:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= January 2020 phase out =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= January 2020 phase out =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;On 1 January 2020, a phase out of virgin R404A went into effect under UK and EU legislation. This included &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;the &lt;/del&gt;ban &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;of &lt;/del&gt;the sale of new refrigeration and air conditioning equipment using new R404A and additional F gases&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;.&lt;/del&gt;with a GWP over 2500.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;On 1 January 2020, a phase out of virgin R404A went into effect under UK and EU legislation. This included &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;a &lt;/ins&gt;ban &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;on &lt;/ins&gt;the sale of new refrigeration and air conditioning equipment using new R404A and additional F gases with a GWP over 2500.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Other refrigerants affected by the ban included R507, R422A, R422D, R434A and R428A. Note: an exception to the ban has been made for military equipment and a few other special instances.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Other refrigerants affected by the ban included R507, R422A, R422D, R434A and R428A. Note: an exception to the ban has been made for military equipment and a few other special instances.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;These refrigerants could be used in new equipment until the end of 2019, but suppliers began to reduce their production in the lead up to the phase out &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;date in 2020&lt;/del&gt;. This resulted in price increases and supply issues.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;These refrigerants could be used in new equipment until the end of 2019, but suppliers began to reduce their production in the lead up to the phase out. This resulted in price increases and supply issues.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;While virgin R404A can no longer be used in new equipment, recovered or reclaimed R404A can be used until the end of 2030. After that point, all replacement R404A will be banned &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;as well&lt;/del&gt;. These rules apply to R507 and the other gases with a GWP over 2500.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;While virgin R404A can no longer be used in new equipment, recovered or reclaimed R404A can be used until the end of 2030. After that point, all replacement R404A will be banned. These rules &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;also &lt;/ins&gt;apply to R507 and the other gases with a GWP over 2500.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Replacements for R404A =&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;= Replacements for R404A =&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 35:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 35:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;The phase out of virgin R404A has emphasised the importance of proper refrigerant recovery, and reclamation. Improving the reclamation and reuse of recovered products will be a factor in helping to ensure a sufficient supply of R404A until its total ban in 2030.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;The phase out of virgin R404A has emphasised the importance of proper refrigerant recovery, and reclamation. Improving the reclamation and reuse of recovered products will be a factor in helping to ensure a sufficient supply of R404A until its total ban in 2030.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;A refrigerant that has been recovered and recycled &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;is a used refrigerant that &lt;/del&gt;must go &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;through a basic cleaning process. Reclaimed refrigerant goes &lt;/del&gt;through a purification process that returns it - as close as possible - to its original state. Reclaimed products should be certificated and guaranteed to meet &lt;del class=&quot;diffchange diffchange-inline&quot;&gt;a specific standard&lt;/del&gt;.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;A refrigerant that has been recovered and recycled must go through a purification process that returns it - as close as possible - to its original state. Reclaimed products should be certificated and guaranteed to meet &lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;required standards&lt;/ins&gt;.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Unprocessed product that has been recovered from a system should not be stored longer than 12 months. After that time, it should be designated as hazardous waste and disposed of according to the proper environmental regulations.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;Unprocessed product that has been recovered from a system should not be stored longer than 12 months. After that time, it should be designated as hazardous waste and disposed of according to the proper environmental regulations.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Designing Buildings</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=196942&amp;oldid=prev</id>
		<title>Editor: Created page with &quot;= Introduction =  R404A is a type of fluorinated gas (F gas) that is known as a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However,...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=R404A_phase_out&amp;diff=196942&amp;oldid=prev"/>
				<updated>2021-03-04T19:33:51Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;= Introduction =  R404A is a type of fluorinated gas (F gas) that is known as a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However,...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;= Introduction =&lt;br /&gt;
&lt;br /&gt;
R404A is a type of fluorinated gas (F gas) that is known as a hydrofluorocarbon (HFC) blend. It is a mixed refrigerant made from R125, R134a and R143a. However, with a global warming potential (GWP) of 3922, R404A is considered an ozone depleting, highly potent greenhouse gas.&lt;br /&gt;
&lt;br /&gt;
= Background on 404A =&lt;br /&gt;
&lt;br /&gt;
The development of R404A came about due to the need for a substitute refrigerant for R502 and R22. These substances were both phased out on 1 January 2015 as a result of EC regulation EC/1005/2009.&lt;br /&gt;
&lt;br /&gt;
R404A is one of the most common refrigerants used in commercial supermarket chillers, vending machines and other cooling units which have low and medium temperature requirements. It is also frequently used in industrial refrigeration applications.&lt;br /&gt;
&lt;br /&gt;
= January 2020 phase out =&lt;br /&gt;
&lt;br /&gt;
On 1 January 2020, a phase out of virgin R404A went into effect under UK and EU legislation. This included the ban of the sale of new refrigeration and air conditioning equipment using new R404A and additional F gases.with a GWP over 2500.&lt;br /&gt;
&lt;br /&gt;
Other refrigerants affected by the ban included R507, R422A, R422D, R434A and R428A. Note: an exception to the ban has been made for military equipment and a few other special instances.&lt;br /&gt;
&lt;br /&gt;
These refrigerants could be used in new equipment until the end of 2019, but suppliers began to reduce their production in the lead up to the phase out date in 2020. This resulted in price increases and supply issues.&lt;br /&gt;
&lt;br /&gt;
While virgin R404A can no longer be used in new equipment, recovered or reclaimed R404A can be used until the end of 2030. After that point, all replacement R404A will be banned as well. These rules apply to R507 and the other gases with a GWP over 2500.&lt;br /&gt;
&lt;br /&gt;
= Replacements for R404A =&lt;br /&gt;
&lt;br /&gt;
In response to these actions, lower GWP alternatives to R404A have become available. Initially, there were two main R404A replacements of similar composition - R407C and R407A. Additional products have been introduced for different applications.&lt;br /&gt;
&lt;br /&gt;
Non-flammable substitutions suitable for cold rooms and other small to medium commercial refrigeration applications include R452A, R449A, R448A. Other alternatives, R513A and R134A are suitable in medium back pressure (MBP) applications.&lt;br /&gt;
&lt;br /&gt;
A3-class refrigerants such as R290 and R600A could be used in new equipment for small, self-contained units (typically in food service).&lt;br /&gt;
&lt;br /&gt;
Mildly flammable replacements include R454A, R454C and R455A.&lt;br /&gt;
&lt;br /&gt;
Hydrofluro-olefins or HFO refrigerants are another class of refrigerants with lower GWP. These substances may also benefit from the phase out of R404A.&lt;br /&gt;
&lt;br /&gt;
= Refrigerant recovery =&lt;br /&gt;
&lt;br /&gt;
The phase out of virgin R404A has emphasised the importance of proper refrigerant recovery, and reclamation. Improving the reclamation and reuse of recovered products will be a factor in helping to ensure a sufficient supply of R404A until its total ban in 2030.&lt;br /&gt;
&lt;br /&gt;
A refrigerant that has been recovered and recycled is a used refrigerant that must go through a basic cleaning process. Reclaimed refrigerant goes through a purification process that returns it - as close as possible - to its original state. Reclaimed products should be certificated and guaranteed to meet a specific standard.&lt;br /&gt;
&lt;br /&gt;
Unprocessed product that has been recovered from a system should not be stored longer than 12 months. After that time, it should be designated as hazardous waste and disposed of according to the proper environmental regulations.&lt;br /&gt;
&lt;br /&gt;
= Related articles on Designing Buildings Wiki =&lt;br /&gt;
&lt;br /&gt;
* EMEA compressor market 2020 - 2023.&lt;br /&gt;
* F gases.&lt;br /&gt;
* Greenhouse gases.&lt;br /&gt;
* HFC phase out.&lt;br /&gt;
* Montreal Protocol.&lt;br /&gt;
* Ozone depleting substances.&lt;br /&gt;
* R22 phase out.&lt;br /&gt;
* Refrigerants in buildings.&lt;br /&gt;
* Refrigerant selection.&lt;br /&gt;
&lt;br /&gt;
[[Category:DCN_Guidance]] [[Category:DCN_Legislation]] [[Category:DCN_Product_Knowledge]] [[Category:DCN_Regulation]] [[Category:DCN_Standard]] [[Category:News]] [[Category:Standards_/_measurements]] [[Category:Products_/_components]]&lt;/div&gt;</summary>
		<author><name>Editor</name></author>	</entry>

	</feed>