<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="https://www.designingbuildings.co.uk/skins/common/feed.css?301"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www.designingbuildings.co.uk/w/index.php?action=history&amp;feed=atom&amp;title=Energy_Performance_Ratio_for_New_Constructions</id>
		<title>Energy Performance Ratio for New Constructions - Revision history</title>
		<link rel="self" type="application/atom+xml" href="https://www.designingbuildings.co.uk/w/index.php?action=history&amp;feed=atom&amp;title=Energy_Performance_Ratio_for_New_Constructions"/>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Energy_Performance_Ratio_for_New_Constructions&amp;action=history"/>
		<updated>2026-05-15T15:28:47Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.17.4</generator>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=Energy_Performance_Ratio_for_New_Constructions&amp;diff=196469&amp;oldid=prev</id>
		<title>Designing Buildings at 07:31, 2 March 2021</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Energy_Performance_Ratio_for_New_Constructions&amp;diff=196469&amp;oldid=prev"/>
				<updated>2021-03-02T07:31:17Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 07:31, 2 March 2021&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 19:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 19:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Home energy performance ratio.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Home energy performance ratio.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;minus;&lt;/td&gt;&lt;td style=&quot;background: #ffa; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;[[Category:&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;Definitions&lt;/del&gt;]] [[Category:&lt;del class=&quot;diffchange diffchange-inline&quot;&gt;DCN_Definition&lt;/del&gt;]] [[Category:BREEAM]]&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;[[Category:&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;DCN_Definition&lt;/ins&gt;]] [[Category:&lt;ins class=&quot;diffchange diffchange-inline&quot;&gt;Definitions&lt;/ins&gt;]] [[Category:BREEAM]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Designing Buildings</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=Energy_Performance_Ratio_for_New_Constructions&amp;diff=158139&amp;oldid=prev</id>
		<title>Designing Buildings: Created page with &quot;[https://www.breeam.com/discover/technical-standards/newconstruction/ BREEAM UK New Construction, Non-domestic Buildings (United Kingdom), Technical Manual, SD5078: BREEAM UK New...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Energy_Performance_Ratio_for_New_Constructions&amp;diff=158139&amp;oldid=prev"/>
				<updated>2020-04-05T07:57:43Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;[https://www.breeam.com/discover/technical-standards/newconstruction/ BREEAM UK New Construction, Non-domestic Buildings (United Kingdom), Technical Manual, SD5078: BREEAM UK New...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;[https://www.breeam.com/discover/technical-standards/newconstruction/ BREEAM UK New Construction, Non-domestic Buildings (United Kingdom), Technical Manual, SD5078: BREEAM UK New Construction 2018 3.0], published by BRE Global Limited, defines the Energy Performance Ratio for New Constructions (EPR_{NC}) as:&lt;br /&gt;
&lt;br /&gt;
‘…a metric that is unique to BREEAM and calculated by the BREEAM Ene 01 Calculator within the BREEAM Assessment Scoring and Reporting tool, using modelled outputs from the approved building energy calculation software. It is a ratio that defines the performance of a BREEAM-assessed building in terms of its regulated operational heating and cooling energy demand, primary energy consumption and CO-eq emissions. This measure of performance is used to determine the number of Ene 01 credits a building achieves in the BREEAM assessment.’&lt;br /&gt;
&lt;br /&gt;
A description of how the EPR_{NC} is defined and calculated is summarised in Energy performance on page 132 of SD5078, and outlined in greater detail in a Guidance Note available from the BREEAM website [https://www.breeam.com/ https://www.breeam.com/].&lt;br /&gt;
&lt;br /&gt;
--[[User:BRE_Group|BRE Group]]&lt;br /&gt;
&lt;br /&gt;
= .Related articles on Designing Buildings Wiki =&lt;br /&gt;
&lt;br /&gt;
* Approved building energy calculation software.&lt;br /&gt;
* BRE articles.&lt;br /&gt;
* BREEAM.&lt;br /&gt;
* Building Research Establishment.&lt;br /&gt;
* ISBEM&lt;br /&gt;
* National Calculation Method.&lt;br /&gt;
* Simplified Building Energy Model.&lt;br /&gt;
* Standard Assessment Procedure.&lt;br /&gt;
* Home energy performance ratio.&lt;br /&gt;
&lt;br /&gt;
[[Category:Definitions]] [[Category:DCN_Definition]] [[Category:BREEAM]]&lt;/div&gt;</summary>
		<author><name>Designing Buildings</name></author>	</entry>

	</feed>