	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=Dry_pipe_valve&amp;diff=181193&amp;oldid=prev</id>
		<title>Designing Buildings at 09:00, 8 November 2020</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Dry_pipe_valve&amp;diff=181193&amp;oldid=prev"/>
				<updated>2020-11-08T09:00:50Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 09:00, 8 November 2020&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 17:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* K factor.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* K factor.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Making the case for sprinklers and dispelling myths.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Making the case for sprinklers and dispelling myths.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;* Mechanical type dry pipe valve.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Overview of automatic sprinkler system design and operation.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Overview of automatic sprinkler system design and operation.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Sprinkler systems explained: A guide to sprinkler installation standards and rules.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;* Sprinkler systems explained: A guide to sprinkler installation standards and rules.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Designing Buildings</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=Dry_pipe_valve&amp;diff=179313&amp;oldid=prev</id>
		<title>Designing Buildings at 08:37, 25 October 2020</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Dry_pipe_valve&amp;diff=179313&amp;oldid=prev"/>
				<updated>2020-10-25T08:37:38Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 08:37, 25 October 2020&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 2:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;[https://www.redbooklive.com/lps.jsp LPS 1041 – 1.3, Requirements and testing procedures for the LPCB approval and listing of dry pipe valve sets], published by BRE Global in 2014, suggests that a dry pipe valve is an: ‘Automatic sprinkler water-supply control valve designed so that air pressure in a system of piping will hold back water pressure until the air pressure in the system is lowered sufficiently to cause automatic operation of the valve and admission of the water in the system, or the valve is tripped by direct action by an accelerator.’&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;[https://www.redbooklive.com/lps.jsp LPS 1041 – 1.3, Requirements and testing procedures for the LPCB approval and listing of dry pipe valve sets], published by BRE Global in 2014, suggests that a dry pipe valve is an: ‘Automatic sprinkler water-supply control valve designed so that air pressure in a system of piping will hold back water pressure until the air pressure in the system is lowered sufficiently to cause automatic operation of the valve and admission of the water in the system, or the valve is tripped by direct action by an accelerator.’&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;A dry pipe valve set is: 'An assembly complete with dry pipe valve, trim and water motor alarm. Optional items, such as accelerator, exhauster, flow meter, pressure switch and flow switch may also be included as part of the dry pipe valve set.'&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;See also: Differential type dry pipe valve.&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;See also: Differential type dry pipe valve.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Designing Buildings</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=Dry_pipe_valve&amp;diff=177597&amp;oldid=prev</id>
		<title>Designing Buildings: Created page with &quot;The Loss Prevention Certification Board (LPCB part of BRE Global) sets the standards needed to ensure that fire and security products and services perform effectively. LPCB’s L...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Dry_pipe_valve&amp;diff=177597&amp;oldid=prev"/>
				<updated>2020-10-11T18:00:30Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;The Loss Prevention Certification Board (LPCB part of BRE Global) sets the standards needed to ensure that fire and security products and services perform effectively. LPCB’s L...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;The Loss Prevention Certification Board (LPCB part of BRE Global) sets the standards needed to ensure that fire and security products and services perform effectively. LPCB’s Loss Prevention Standards (LPS) are applied in fire and security sectors around the world.&lt;br /&gt;
&lt;br /&gt;
[https://www.redbooklive.com/lps.jsp LPS 1041 – 1.3, Requirements and testing procedures for the LPCB approval and listing of dry pipe valve sets], published by BRE Global in 2014, suggests that a dry pipe valve is an: ‘Automatic sprinkler water-supply control valve designed so that air pressure in a system of piping will hold back water pressure until the air pressure in the system is lowered sufficiently to cause automatic operation of the valve and admission of the water in the system, or the valve is tripped by direct action by an accelerator.’&lt;br /&gt;
&lt;br /&gt;
See also: Differential type dry pipe valve.&lt;br /&gt;
&lt;br /&gt;
--[[User:BRE_Group|BRE Group]]&lt;br /&gt;
&lt;br /&gt;
= Related articles on Designing Buildings Wiki =&lt;br /&gt;
&lt;br /&gt;
* BRE articles on Designing Buildings Wiki.&lt;br /&gt;
* Clapper.&lt;br /&gt;
* Differential ratio of a wet alarm valve.&lt;br /&gt;
* Differential type dry pipe valve.&lt;br /&gt;
* K factor.&lt;br /&gt;
* Making the case for sprinklers and dispelling myths.&lt;br /&gt;
* Overview of automatic sprinkler system design and operation.&lt;br /&gt;
* Sprinkler systems explained: A guide to sprinkler installation standards and rules.&lt;br /&gt;
* Sprinkler.&lt;br /&gt;
* The cost efficiency of different combinations of fire protection measures.&lt;br /&gt;
* The impact of automatic sprinklers on building design.&lt;br /&gt;
* Watermist systems for fire protection in domestic and residential buildings DG 534.&lt;br /&gt;
* Wet alarm valve.&lt;br /&gt;
&lt;br /&gt;
[[Category:DCN_Definition]] [[Category:DCN_Product_Knowledge]] [[Category:Definitions]] [[Category:Products_/_components]]&lt;/div&gt;</summary>