<?xml version="1.0"?>
<?xml-stylesheet type="text/css" href="https://www.designingbuildings.co.uk/skins/common/feed.css?301"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
		<id>https://www.designingbuildings.co.uk/w/index.php?action=history&amp;feed=atom&amp;title=Dezincification</id>
		<title>Dezincification - Revision history</title>
		<link rel="self" type="application/atom+xml" href="https://www.designingbuildings.co.uk/w/index.php?action=history&amp;feed=atom&amp;title=Dezincification"/>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Dezincification&amp;action=history"/>
		<updated>2026-04-06T16:26:05Z</updated>
		<subtitle>Revision history for this page on the wiki</subtitle>
		<generator>MediaWiki 1.17.4</generator>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=Dezincification&amp;diff=235758&amp;oldid=prev</id>
		<title>Designing Buildings at 06:33, 28 July 2022</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Dezincification&amp;diff=235758&amp;oldid=prev"/>
				<updated>2022-07-28T06:33:31Z</updated>
		
		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: white; color:black;&quot;&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
			&lt;col class='diff-marker' /&gt;
			&lt;col class='diff-content' /&gt;
		&lt;tr valign='top'&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;← Older revision&lt;/td&gt;
		&lt;td colspan='2' style=&quot;background-color: white; color:black;&quot;&gt;Revision as of 06:33, 28 July 2022&lt;/td&gt;
		&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;[https://www.bsria.com/uk/product/Bxmbqr/water_treatment_for_closed_heating_and_cooling_systems_bg_502021_a15d25e1 Water Treatment for Closed Heating and Cooling Systems (BG 50/2021), second edition], by Dr Pamela Simpson, published by BSRIA in 2021, defines dezincification as: ‘Corrosion of brass (an alloy of copper and zinc) where the zinc is preferentially removed to leave a weak porous matrix of copper.’&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;[https://www.bsria.com/uk/product/Bxmbqr/water_treatment_for_closed_heating_and_cooling_systems_bg_502021_a15d25e1 Water Treatment for Closed Heating and Cooling Systems (BG 50/2021), second edition], by Dr Pamela Simpson, published by BSRIA in 2021, defines dezincification as: ‘Corrosion of brass (an alloy of copper and zinc) where the zinc is preferentially removed to leave a weak porous matrix of copper.’&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot;&gt;&amp;#160;&lt;/td&gt;&lt;td class='diff-marker'&gt;+&lt;/td&gt;&lt;td style=&quot;background: #cfc; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;color: red; font-weight: bold; text-decoration: none;&quot;&gt;[https://www.bsria.com/uk/product/oBKvLD/illustrated_guide_to_hot_and_cold_water_services_bg_332014_a15d25e1/ The Illustrated Guide to Hot and Cold Water Services (BG 33/2014)], written by Reginald Brown and published by BSRIA in 2014, in suggests that dezincification of brass occurs when: ‘…zinc is selectively leached from a brass component leaving behind a porous mass of copper. This is much weaker than the original brass and can result in mechanical failure of stressed components. The problem is more likely in potable water systems than heating or chilled water as it requires a high oxygen concentration.’&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;--[[User:BSRIA|BSRIA]]&lt;/div&gt;&lt;/td&gt;&lt;td class='diff-marker'&gt;&amp;#160;&lt;/td&gt;&lt;td style=&quot;background: #eee; color:black; font-size: smaller;&quot;&gt;&lt;div&gt;--[[User:BSRIA|BSRIA]]&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>Designing Buildings</name></author>	</entry>

	<entry>
		<id>https://www.designingbuildings.co.uk/w/index.php?title=Dezincification&amp;diff=218507&amp;oldid=prev</id>
		<title>Designing Buildings: Created page with &quot;[https://www.bsria.com/uk/product/Bxmbqr/water_treatment_for_closed_heating_and_cooling_systems_bg_502021_a15d25e1 Water Treatment for Closed Heating and Cooling Systems (BG 50/2...&quot;</title>
		<link rel="alternate" type="text/html" href="https://www.designingbuildings.co.uk/w/index.php?title=Dezincification&amp;diff=218507&amp;oldid=prev"/>
				<updated>2021-11-18T07:50:12Z</updated>
		
		<summary type="html">&lt;p&gt;Created page with &amp;quot;[https://www.bsria.com/uk/product/Bxmbqr/water_treatment_for_closed_heating_and_cooling_systems_bg_502021_a15d25e1 Water Treatment for Closed Heating and Cooling Systems (BG 50/2...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;[https://www.bsria.com/uk/product/Bxmbqr/water_treatment_for_closed_heating_and_cooling_systems_bg_502021_a15d25e1 Water Treatment for Closed Heating and Cooling Systems (BG 50/2021), second edition], by Dr Pamela Simpson, published by BSRIA in 2021, defines dezincification as: ‘Corrosion of brass (an alloy of copper and zinc) where the zinc is preferentially removed to leave a weak porous matrix of copper.’&lt;br /&gt;
&lt;br /&gt;
--[[User:BSRIA|BSRIA]]&lt;br /&gt;
&lt;br /&gt;
= Related articles on Designing Buildings =&lt;br /&gt;
&lt;br /&gt;
* Brass.&lt;br /&gt;
* BSRIA articles on Designing Buildings.&lt;br /&gt;
* BSRIA definitions.&lt;br /&gt;
* BSRIA.&lt;br /&gt;
* Cooling.&lt;br /&gt;
* Corrosion.&lt;br /&gt;
* Heating.&lt;br /&gt;
* Types of water.&lt;br /&gt;
* Water engineering&lt;br /&gt;
* Water treatment.&lt;br /&gt;
* Water.&lt;br /&gt;
&lt;br /&gt;
[[Category:DCN_Definition]] [[Category:Definitions]]&lt;/div&gt;</summary>
		<author><name>Designing Buildings</name></author>	</entry>

	</feed>