Vapour barrier
As warm, moist internal air permeates through the external envelope of a building towards the outside, it will tend to cool. When it reaches its ‘dew point’ temperature, the moisture it holds will begin to condense as water. If this happens within the structure of the building itself, this is known as interstitial condensation.
If interstitial condensation occurs within the inner skin of the building envelope, it can cause problems such as:
- Mould growth, migration of salts, mildew and staining.
- Corrosion and decay of the building fabric.
- Frost damage.
- Poor performance of insulation.
To prevent this, vapour control layers (VCL) or vapour barriers are positioned on the warm side of the structure, preventing the warm moist air from penetrating to a point where it might reach its dew point temperature. In a traditional cavity wall construction for example, a vapour barrier might be introduced between the cavity insulation and the inner masonry skin.
Vapour barriers might also be used in timber frame constructions, roof and floor constructions as well as in high humidity buildings such as swimming pools and factories.
Care must be taken to ensure that vapour barriers are installed properly, so that they are continuous, and that joints, edges, junctions, cuts and penetrations are sealed. Particular care must be taken around openings such as ceiling hatches, and service penetrations such as cables, ducts, sockets, light fittings, and so on.
As well as preventing interstitial condensation, vapour barriers can improve the airtightness of the buildings. However, typically vapour barriers have a very low permeability, but are not completely airtight. Where they are airtight, they may be described as air and vapour control layers (AVCLs). Preventing the passage of air through the structure, can improve its thermal performance. In addition, some vapour barriers may include a low-e (low emissivity) metalised foil in their construction to improve thermal efficiency.
Vapour barriers may include an adhesive face, or adhesive laps and may have some ‘elastomric’ properties, giving a limited self-sealing capability if penetrated.
Some types of rigid foam insulation have a foil bonded to their surface which will act as a vapour barrier, however, care must still be taken to ensure that joints and edges are properly sealed.
[edit] Related articles on Designing Buildings Wiki
Featured articles and news
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
UK gov apprenticeship funding from April 2024
Brief summary the policy paper updated in March.
For the World Autism Awareness Month of April.
70+ experts appointed to public sector fire safety framework
The Fire Safety (FS2) Framework from LHC Procurement.
Project and programme management codes of practice
CIOB publications for built environment professionals.
The ECA Industry Awards 2024 now open !
Recognising the best in the electrotechnical industry.
Sustainable development concepts decade by decade.
The regenerative structural engineer
A call for design that will repair the natural world.
Buildings that mimic the restorative aspects found in nature.
CIAT publishes Principal Designer Competency Framework
For those considering applying for registration as a PD.
BSRIA Building Reg's guidance: The second staircase
An overview focusing on aspects which most affect the building services industry.
Design codes and pattern books
Harmonious proportions and golden sections.
Introducing or next Guest Editor Arun Baybars
Practising architect and design panel review member.
Quick summary by size, shape, test, material, use or bonding..