Multi-sensor alarm
The Technical Handbook – Domestic, published by Scottish Ministers to provide guidance on the Scottish building standards suggests there are 4 main types of fire detector used in dwellings:
- Optical smoke alarms.
- Ionisation smoke alarms.
- Multi-sensor alarms.
- Heat alarms.
Alarms may be hard wired or battery operated, and may be interconnected so that if one detector is triggered, all interconnected alarms sound.
It is important that the right type of fire detector is used for different situations, as false alarms can result in occupants ignoring or disabling fire detection and fire alarm systems.
The most common causes of false alarms are:
Multi-sensor alarms (or multi-criteria alarms) detect more than one fire phenomena, for example optical and heat detection. They may also include other detection capabilities, such as carbon monoxide detection.
A multi-sensor alarm provides early warning of fire and can significantly reduce the number of unwanted false alarms in certain circumstances.
Research by BRE, published in 2014, suggested that replacement of existing detectors in Kings College London with intelligent multi-sensor detectors could reduce false alarms by 69%, and that in the general building stock, the increased use of multi-sensor detectors may avert false alarms from common causes such as cooking fumes, steam and so on. Ref The causes of false fire alarms in buildings.
Intelligent multi-sensor alarms are independently addressed and continuously monitored to verify correct operation. They may also have adjustable sensitivity settings and drift compensation to account for environmental conditions. This can help identify when an alarm is genuine, as opposed to resulting from a maintenance issue or incorrect setting.
In dwellings, multi-sensor alarms are recommended in hallways and stairwells adjacent to bathrooms or shower rooms to reduce the number of unwanted false alarms.
For more information, see the BS 5839 series of standards for fire detection and fire alarm systems for buildings.
[edit] Related articles on Designing Buildings
- Carbon monoxide.
- Carbon monoxide detector.
- Electrotechnical industry gears up for All-IP switch.
- Fire.
- Fire detection and alarm system.
- Fire fatalities in Scotland.
- Heat alarm.
- Intruder alarm.
- Ionisation smoke alarms.
- Live investigations of false fire alarms.
- New requirements for fire detection and alarm network systems IP 12 13.
- Optical smoke alarm.
- Over £1 billion lost every year due to false alarms.
- Smoke detection in high ceiling spaces.
- Smoke detector.
- The causes of false fire alarms in buildings.
Featured articles and news
Not buildings. Happy holiday from DB.
Future Homes Standard: Industry calls for more ambition
As the Government FHS consultation finally closes.
Improving government projects with data and AI
Enabling better outcomes, efficient modern delivery and influential leadership on government projects.
BSRIA Living Laboratory Innovation Challenge
Final days for submission, closing March 29.
Windows, their frames, forms, factors and functions.
The hidden subtleties of U-Value calculations
Different contexts and what to include as variables.
A brief run down with related articles.
Electrical sector calls for safer public EV charge points
Serious concerns about electrical safety in the public domain.
Building Blocks manifesto presented to parliament
Architects Declare call in for support of five critical policies.
The four elements of project management with APM
Analysis, expectations, collaborative communication and partnerships.
City of London launches Heritage Building Retrofit Toolkit
Empowering owners to initiate necessary adaptations.
Guidance on RAAC in listed buildings
Published by Purcell, endorsed by IHBC, SPAB and C20.
Learning from the past.
Reluctance to hire people with criminal convictions revealed
Employing People with Criminal Convictions Report.
Tackling unconscious bias; Women's History Month
Personal reflections, as the last week of March approaches.