Last edited 19 Oct 2016

Cavity wall


[edit] History

A cavity wall is a wall formed by an inner skin and an outer skin of masonry (sometimes referred to as ‘leaves’ or ‘wythes’ if they are a single unit wide), connected by ties, but separated by a cavity. The masonry is formed by hard units such as brick, stone or block.

Very generally, if the external walls of a building are less than 30cm thick, then they are unlikely to include a cavity.

Cavity walls existed in Greek and Roman times, however, they only developed as a component in more recent construction in the 18th the 19th centuries. Even during this time, they were very rare, and generally involved two skins of masonry bonded by header spanning across the cavity. The use of metal ties to connect the two skins only emerged in the second half of the 19th century and then became more common toward the beginning of the 20th century.

In the UK, since the 1920’s, most new, external masonry walls of buildings have been cavity walls.

Cavity wall.jpg

[edit] Penetrating damp

The inclusion of a cavity in the construction of an external wall prevents moisture transmitting from the outer skin to the inner skin. Any moisture that reaches the cavity from the outside, will run down the internal surface of the external skin and will be directed to weep holes in the outer skin by cavity trays, where it will then drain to the outside.

Cavity trays are included in where there are penetrations across the cavity, such as:

  • At an abutment with a roof.
  • Above openings such as doors and windows.
  • Where extensions are constructed against existing walls.
  • Above concrete slabs or beams.
  • Above airbricks, ducts and pipes.
  • At the bottom of a wall, if the cavity does not extend 225mm below the damp-proof course.

Cavity tray.jpg

Cavities are ventilated to ensure that any accumulating moisture is able to evaporate and vent to the outside.

[edit] Insulation

Cavities can also provide a space for the installation of thermal insulation, and as the requirement to reduce the passage of heat between the inside and outside of buildings has increased, so the width of cavities has also tended to increase.

This means that older buildings tend to transfer more heat between the inside and outside and so can be colder in the winter, hotter in the summer, can suffer condensation, can be expensive to run, are high emitters of carbon and may not provide very good levels of thermal comfort.

Typically the U-values (a measure thermal conductance) of walls are:

  • Solid brick wall 2.0 W/m2K.
  • Cavity wall with no insulation 1.5 W/m2K.
  • Insulated cavity wall 0.3 W/m2K.

Insulation is generally fixed to the external face of the internal skin of the cavity wall. This allows the remainder of the cavity to be ventilated without significant heat loss. However, in some cases, particularly where insulation is retrofitted, the entire cavity is filled. Great care must be taken in this case to ensure that a path is not created for the penetration of moisture between the outside and inside.

Cavity wall insulation.jpg

Cavity walls that are not insulated can have insulation retrofitted by drilling small holes at regular intervals in the external skin and then ‘blowing’ or ‘injecting’ insulation into the cavity from the outside. Typically, water-repellent insulation is used such as; mineral wool, Expanded Polystyrene (EPS) beads combined with a binding agent, or Urea Formaldehyde (UF) foam insulation. The drilled holes are then filled to match the existing finish. See Cavity wall insulation for more information.

Insulating solid walls is more complicated, and so more expensive, involving insulation of either the outside or the inside of the wall. See Solid wall insulation for more information.

[edit] Vapour barrier

As warm, moist internal air permeates through the structure of the wall towards the outside, it will tend to cool. When it reaches its ‘dew pointtemperature, moisture will begin to condense as water. If this happens within the structure of the wall, this is known as interstitial condensation, and if this occurs within the inner skin of the wall, this can cause problems such as:

To prevent this, Vapour Control Layers (VCL) or vapour barriers are positioned on the warm side of the cavity insulation, (ie, between the insulation and the inner masonry skin) preventing the warm moist air from penetrating to a point where it might reach its dew point temperature.

[edit] Find out more